Home
CMS Production
Clean room
MedAustron
HEPHY
testbeams
old
testbeam-MA2018
testbeam-MA2019
testbeam-MA2020
testbeam-MA2021
testbeam-MA2023
testbeam-MA2024
Testbeams at MedAustron in 2024, Page 5 of 5
Not logged in
Find
|
Login
|
Help
Full
| Summary |
Threaded
-- All entries --
Last day
Last 3 Days
Last week
Last month
Last 3 Months
Last 6 Months
Last Year
-- DUT --
common
DSSD-Tracker
RD50-MPW4
TJ-Monopix2
Wxxx topside
TOF-Cal GSI
-- Beam Energy --
800 MeV
252.7 MeV
194.3 MeV
175.3 MeV
145.4 MeV
100.4 MeV
83 MeV
62.4 MeV
4.2
115.7MeV
100 Entries
Goto page
Previous
1
,
2
,
3
,
4
, 5
All
ID
Date
Author
Subject
Run Number
DUT
Beam Energy
Rate Setting
Particle Type
Data
t-Start
t-Stop
Duration_min
Frontend
Text
90
Sun Jun 9 00:08:07 2024
Felix Ulrich-Pur
TOF CAL HADES LGADs WET Messung Wasser
19
TOF-Cal GSI
194.3 MeV
Low Flux High
Proton
Good
23:20
23:30
5 cm plastic water (in isocentre)
3.7 Mhz on Ramon (after 5 Layers of
Silicon and close to second iso centre) and
92
Sun Jun 9 00:12:41 2024
Felix Ulrich-Pur
TOF CAL HADES LGADs WET Messung Knochen
21
TOF-Cal GSI
194.3 MeV
Low Flux High
Proton
Good
00:00
00:14
1 cm dense bone (in isocentre)
4.5 Mhz on Ramon (after 5 Layers of
Silicon and close to second iso centre) and
94
Sun Jun 9 01:25:26 2024
Felix Ulrich-Pur
TOF CAL HADES LGADs WET Messung Knochen
23
TOF-Cal GSI
194.3 MeV
Low Flux High
Proton
Good
00:30
01:02
2 cm dense bone (in isocentre)
- Mhz on Ramon (after 5 Layers of
Silicon and close to second iso centre) and
96
Sun Jun 9 01:27:38 2024
Felix Ulrich-Pur
TOF CAL HADES LGADs WET Messung Knochen
25
TOF-Cal GSI
194.3 MeV
Low Flux High
Proton
Good
01:16
01:30
3 cm dense bone (in isocentre)
2.8 Mhz on Ramon (after 5 Layers of
Silicon and close to second iso centre) and
98
Sun Jun 9 01:48:51 2024
Felix Ulrich-Pur
TOF CAL HADES LGADs WET Messung Knochen
27
TOF-Cal GSI
194.3 MeV
Low Flux High
Proton
Good
01:48
01:59
4 cm dense bone (in isocentre)
2 Mhz on Ramon (after 5 Layers of
Silicon and close to second iso centre) and
101
Sun Jun 9 02:18:55 2024
Felix Ulrich-Pur
TOF CAL HADES LGADs WET Messung Knochen
29
TOF-Cal GSI
194.3 MeV
Low Flux High
Proton
Good
02:18
5 cm dense bone (in isocentre)
1.8 Mhz on Ramon (after 5 Layers of
Silicon and close to second iso centre) and
75
Sat Jun 8 20:05:27 2024
Felix Ulrich-Pur
TOF CAL HADES LGADs Calibrationcurve
4
TOF-Cal GSI
175.3 MeV
Low Flux Medium
Proton
Good
17:31
17:54
500 khz on Ramon (after 5 Layers of Silicon
and close to second iso centre) and 170kHz
on LGAD
76
Sat Jun 8 20:07:44 2024
Felix Ulrich-Pur
TOF CAL HADES LGADs Calibrationcurve
5
TOF-Cal GSI
145.4 MeV
Low Flux Medium
Proton
Good
17:55
18:24
400 khz on Ramon (after 5 Layers of Silicon
and close to second iso centre) and 120kHz
on LGAD
82
Sat Jun 8 21:43:26 2024
Felix Ulrich-Pur
TOF CAL HADES LGADs WET Messung Wasser
11
TOF-Cal GSI
145.4 MeV
Low Flux High
Proton
Good
21:39
21:48
1cm plastic water (in isocentre)
4 Mhz on Ramon (after 5 Layers of
Silicon and close to second iso centre) and
84
Sat Jun 8 22:12:06 2024
Felix Ulrich-Pur
TOF CAL HADES LGADs WET Messung Wasser
13
TOF-Cal GSI
145.4 MeV
Low Flux High
Proton
Good
22:05
22:34
2cm plastic water (in isocentre)
3.2 Mhz on Ramon (after 5 Layers of
Silicon and close to second iso centre) and
89
Sun Jun 9 00:07:17 2024
Felix Ulrich-Pur
TOF CAL HADES LGADs WET Messung Wasser
18
TOF-Cal GSI
145.4 MeV
Low Flux High
Proton
Good
23:04
23:20
4 cm plastic water (in isocentre)
2 Mhz on Ramon (after 5 Layers of
Silicon and close to second iso centre) and
91
Sun Jun 9 00:10:38 2024
Felix Ulrich-Pur
TOF CAL HADES LGADs WET Messung Wasser
20
TOF-Cal GSI
145.4 MeV
Low Flux High
Proton
Good
23:31
00:00
5 cm plastic water (in isocentre)
2 Mhz on Ramon (after 5 Layers of
Silicon and close to second iso centre) and
93
Sun Jun 9 01:22:48 2024
Felix Ulrich-Pur
TOF CAL HADES LGADs WET Messung Knochen
22
TOF-Cal GSI
145.4 MeV
Low Flux High
Proton
Good
00:14
00:23
1 cm dense bone (in isocentre)
2.8 Mhz on Ramon (after 5 Layers of
Silicon and close to second iso centre) and
95
Sun Jun 9 01:26:56 2024
Felix Ulrich-Pur
TOF CAL HADES LGADs WET Messung Knochen
24
TOF-Cal GSI
145.4 MeV
Low Flux High
Proton
Good
01:02
01:14
2 cm dense bone (in isocentre)
2.1 Mhz on Ramon (after 5 Layers of
Silicon and close to second iso centre) and
97
Sun Jun 9 01:32:51 2024
Felix Ulrich-Pur
TOF CAL HADES LGADs WET Messung Knochen
26
TOF-Cal GSI
145.4 MeV
Low Flux High
Proton
Good
01:30
01:45
3 cm dense bone (in isocentre)
1.7 Mhz on Ramon (after 5 Layers of
Silicon and close to second iso centre) and
100
Sun Jun 9 02:02:16 2024
Felix Ulrich-Pur
TOF CAL HADES LGADs WET Messung Knochen
28
TOF-Cal GSI
145.4 MeV
Low Flux High
Proton
Good
02:00
02:14
4 cm dense bone (in isocentre)
1.4 Mhz on Ramon (after 5 Layers of
Silicon and close to second iso centre) and
77
Sat Jun 8 20:08:55 2024
Felix Ulrich-Pur
TOF CAL HADES LGADs Calibrationcurve
6
TOF-Cal GSI
115.7MeV
Low Flux Medium
Proton
Good
18:24
19:00
400 khz on Ramon (after 5 Layers of Silicon
and close to second iso centre) and 65kHz
on LGAD
78
Sat Jun 8 20:09:25 2024
Felix Ulrich-Pur
TOF CAL HADES LGADs Calibrationcurve
7
TOF-Cal GSI
100.4 MeV
Low Flux Medium
Proton
Good
19:00
19:42
300 khz on Ramon (after 5 Layers of Silicon
and close to second iso centre) and 65kHz
on LGAD
1
Sat Mar 30 06:34:39 2024
Bernhard Pilsl
And a new testbeam starts :D
11
Sat Mar 30 08:05:59 2024
Christian Irmler
RD50-MPW4
999
Tracker calibration run: mpw4-tj-monopix2_00-000999.xml
Generated global xml file for MPW4
shift: mpw4-tj-monopix2_TLU_00-000999.xml
Goto page
Previous
1
,
2
,
3
,
4
, 5
All
ELOG V3.1.5-fc6679b