Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024
  Testbeams at MedAustron in 2024, Page 4 of 11  Not logged in ELOG logo
Entry  Sat Mar 30 08:34:12 2024, bp, ci, hh, RD50-MPW4, , RD50-MPW4, 800 MeV, Low Flux Very Low, Proton, Good, , , , Normal, ,  
beam should be back, there was something in the nozzle too
Entry  Sat Mar 30 08:38:21 2024, bp, ci, hh, RD50-MPW4, , RD50-MPW4, 800 MeV, Low Flux Very Low, Proton, Good, , , , Normal, ,  
beam not back, fake news
Entry  Sat Mar 30 08:40:10 2024, bp, ci, hh, RD50-MPW4, 1008, RD50-MPW4, 800 MeV, Low Flux Very Low, Proton, Crap, 30.03.2024 08:37:03, 30.03.2024 08:42:37, 5, Normal, ,  peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 1008
Comment:
waiting for beam
Entry  Sat Mar 30 08:56:25 2024, bp, ci, hh, RD50-MPW4, , RD50-MPW4, 800 MeV, Low Flux Very Low, Proton, Crap, , , , Normal, ,  
waiting for beam
Performing MTS restart
Entry  Sat Mar 30 09:03:54 2024, bp, ci, hh, RD50-MPW4, 1009, RD50-MPW4, 800 MeV, Low Flux Very Low, Proton, Crap, 30.03.2024 08:43:22, 30.03.2024 09:06:20, 22, Normal, ,  peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 1009
Comment:
waiting for beam
Entry  Sat Mar 30 09:15:13 2024, bp, ci, hh, RD50-MPW4, , RD50-MPW4, 800 MeV, Low Flux Very Low, Proton, Crap, , , , Normal, ,  
moved entire setup a bit in order too better focus beam on MPW4 (hopefully)
Entry  Sat Mar 30 09:25:05 2024, bp, ci, hh, RD50-MPW4, , RD50-MPW4, 800 MeV, Low Flux Very Low, Proton, Crap, , , , Normal, ,  
bea is back :D
Entry  Sat Mar 30 09:27:33 2024, bp, ci, hh, RD50-MPW4, 1010, RD50-MPW4, 800 MeV, Low Flux Very Low, Proton, Crap, 30.03.2024 09:23:42, 30.03.2024 09:29:59, 6, Normal, ,  peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 1010
Comment:
Entry  Sat Mar 30 09:36:22 2024, bp, ci, hh, RD50-MPW4, 1011, RD50-MPW4, 800 MeV, Low Flux Very Low, Proton, Good, 30.03.2024 09:30:18, 30.03.2024 09:38:48, 8, Normal, ,  peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 1011
Comment:
testing new tablealignment
Entry  Sat Mar 30 09:42:55 2024, bp, ci, hh, RD50-MPW4, 1012, RD50-MPW4, 800 MeV, Low Flux Low, Proton, Good, 30.03.2024 09:39:08, 30.03.2024 09:45:21, 6, Normal, ,  peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 1012
Comment:
changed rate
Entry  Sat Mar 30 09:43:29 2024, bp, ci, hh, RD50-MPW4, , RD50-MPW4, 800 MeV, Low Flux Low, Proton, Good, , , , Normal, ,  
max triggerof tracker set to 100
Entry  Sat Mar 30 09:53:41 2024, bp, ci, hh, RD50-MPW4, 1013, RD50-MPW4, 800 MeV, Low Flux Low, Proton, Good, 30.03.2024 09:46:27, 30.03.2024 09:56:08, 9, Normal, ,  peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 1013
Comment:
Entry  Sat Mar 30 09:54:37 2024, bp, ci, hh, RD50-MPW4, , RD50-MPW4, 800 MeV, Low Flux Low, Proton, Good, , , , Normal, ,  
correlations still there after rate change
Entry  Sat Mar 30 09:59:25 2024, bp, ci, hh, RD50-MPW4, 1014, RD50-MPW4, 800 MeV, Low Flux Low, Proton, Good, 30.03.2024 09:56:17, 30.03.2024 10:01:51, 5, Normal, ,  peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 1014
Comment:
Entry  Sat Mar 30 09:59:40 2024, bp, ci, hh, RD50-MPW4, , RD50-MPW4, 800 MeV, Low Flux Medium, Proton, Good, , , , Normal, ,  
changed rate
Entry  Sat Mar 30 10:05:09 2024, bp, ci, hh, RD50-MPW4, 1015, RD50-MPW4, 800 MeV, Low Flux Medium, Proton, Good, 30.03.2024 10:02:17, 30.03.2024 10:07:36, 5, Normal, ,  peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 1015
Comment:
changed rate
Entry  Sat Mar 30 10:10:57 2024, bp, ci, hh, RD50-MPW4, 1016, RD50-MPW4, 800 MeV, Low Flux Medium, Proton, Good, 30.03.2024 10:07:51, 30.03.2024 10:13:23, 5, Normal, ,  peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 1016
Comment:
changed rate
Entry  Sat Mar 30 10:23:04 2024, bp, ci, hh, RD50-MPW4, , RD50-MPW4, 800 MeV, Low Flux Low, Proton, Good, , , , Normal, ,  
changed rate to low again, too much "noise"
also moved table down and a bit to the left 
Entry  Sat Mar 30 10:23:06 2024, bp, ci, hh, RD50-MPW4, 1017, RD50-MPW4, 800 MeV, Low Flux Low, Proton, Crap, 30.03.2024 10:25:09, 30.03.2024 10:25:33, 0, Normal, ,  peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 1017
Comment:
changed rate to low again, too much "noise"
Entry  Sat Mar 30 10:25:55 2024, bp, ci, hh, RD50-MPW4, 1018, RD50-MPW4, 800 MeV, Low Flux Low, Proton, Crap, 30.03.2024 10:26:17, 30.03.2024 10:28:21, 2, Normal, ,  peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 1018
Comment:
ELOG V3.1.5-fc6679b