Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024
  Testbeams at MedAustron in 2024, Page 4 of 7  Not logged in ELOG logo
ID Date Author Subject Run Number DUT Beam Energy Rate Settingdown Particle Type Data t-Start t-Stop Duration_min Frontend Text Attachments
  74   Sat Jun 8 19:57:39 2024 Felix Ulrich-PurTOF CAL HADES LGADs Calibrationcurve3TOF-Cal GSI194.3 MeVLow Flux MediumProtonGood16:5117:28  600 khz on Ramon (after 5 Layers of Silicon
and close to second iso centre) and 235kHz
on LGAD
  
  75   Sat Jun 8 20:05:27 2024 Felix Ulrich-PurTOF CAL HADES LGADs Calibrationcurve4TOF-Cal GSI175.3 MeVLow Flux MediumProtonGood17:3117:54  500 khz on Ramon (after 5 Layers of Silicon
and close to second iso centre) and 170kHz
on LGAD
  
  76   Sat Jun 8 20:07:44 2024 Felix Ulrich-PurTOF CAL HADES LGADs Calibrationcurve5TOF-Cal GSI145.4 MeVLow Flux MediumProtonGood17:5518:24  400 khz on Ramon (after 5 Layers of Silicon
and close to second iso centre) and 120kHz
on LGAD
  
  77   Sat Jun 8 20:08:55 2024 Felix Ulrich-PurTOF CAL HADES LGADs Calibrationcurve6TOF-Cal GSI115.7MeVLow Flux MediumProtonGood18:2419:00  400 khz on Ramon (after 5 Layers of Silicon
and close to second iso centre) and 65kHz
on LGAD
  
  78   Sat Jun 8 20:09:25 2024 Felix Ulrich-PurTOF CAL HADES LGADs Calibrationcurve7TOF-Cal GSI100.4 MeVLow Flux MediumProtonGood19:0019:42  300 khz on Ramon (after 5 Layers of Silicon
and close to second iso centre) and 65kHz
on LGAD
  
  79   Sat Jun 8 20:11:00 2024 Felix Ulrich-PurTOF CAL HADES LGADs Calibrationcurve8TOF-Cal GSI83 MeVLow Flux MediumProtonGood19:4220:51  300 khz on Ramon (after 5 Layers of Silicon
and close to second iso centre) and 35kHz
on LGAD
  
  22   Sat Mar 30 09:42:55 2024 bp, ci, hhRD50-MPW41012RD50-MPW4800 MeVLow Flux LowProtonGood30.03.2024 09:39:0830.03.2024 09:45:216Normalautomatic log for run 1012
Comment:
changed rate
 peary_config.cfgmatrix_mpw4.txtmpw4.conf 
  23   Sat Mar 30 09:43:29 2024 bp, ci, hhRD50-MPW4 RD50-MPW4800 MeVLow Flux LowProtonGood   Normalmax triggerof tracker set to 100   
  24   Sat Mar 30 09:53:41 2024 bp, ci, hhRD50-MPW41013RD50-MPW4800 MeVLow Flux LowProtonGood30.03.2024 09:46:2730.03.2024 09:56:089Normalautomatic log for run 1013
Comment:
 peary_config.cfgmatrix_mpw4.txtmpw4.conf 
  25   Sat Mar 30 09:54:37 2024 bp, ci, hhRD50-MPW4 RD50-MPW4800 MeVLow Flux LowProtonGood   Normalcorrelations still there after rate change   
  26   Sat Mar 30 09:59:25 2024 bp, ci, hhRD50-MPW41014RD50-MPW4800 MeVLow Flux LowProtonGood30.03.2024 09:56:1730.03.2024 10:01:515Normalautomatic log for run 1014
Comment:
 peary_config.cfgmatrix_mpw4.txtmpw4.conf 
  30   Sat Mar 30 10:23:04 2024 bp, ci, hhRD50-MPW4 RD50-MPW4800 MeVLow Flux LowProtonGood   Normalchanged rate to low again, too much "noise"
also moved table down and a bit to the left
  
  31   Sat Mar 30 10:23:06 2024 bp, ci, hhRD50-MPW41017RD50-MPW4800 MeVLow Flux LowProtonCrap30.03.2024 10:25:0930.03.2024 10:25:330Normalautomatic log for run 1017
Comment:
changed rate to low again, too much "noise"
 peary_config.cfgmatrix_mpw4.txtmpw4.conf 
  32   Sat Mar 30 10:25:55 2024 bp, ci, hhRD50-MPW41018RD50-MPW4800 MeVLow Flux LowProtonCrap30.03.2024 10:26:1730.03.2024 10:28:212Normalautomatic log for run 1018
Comment:
 peary_config.cfgmatrix_mpw4.txtmpw4.conf 
  33   Sat Mar 30 10:27:56 2024 bp, ci, hhRD50-MPW41019RD50-MPW4800 MeVLow Flux LowProtonCrap30.03.2024 10:28:2830.03.2024 10:30:221Normalautomatic log for run 1019
Comment:
 peary_config.cfgmatrix_mpw4.txtmpw4.conf 
  34   Sat Mar 30 10:28:42 2024 bp, ci, hhRD50-MPW4 RD50-MPW4800 MeVLow Flux LowProtonGood   Normaltracker FADC down, HV not on earlier, restart
happening
  
  35   Sat Mar 30 10:34:27 2024 bp, ci, hhRD50-MPW41020RD50-MPW4800 MeVLow Flux LowProtonGood30.03.2024 10:33:0130.03.2024 10:36:533Normalautomatic log for run 1020
Comment:
 peary_config.cfgmatrix_mpw4.txtmpw4.conf 
  36   Sat Mar 30 10:39:45 2024 bp, ci, hhRD50-MPW41021RD50-MPW4800 MeVLow Flux LowProtonGood30.03.2024 10:37:0130.03.2024 10:42:125Normalautomatic log for run 1021
Comment:
no tracker at start of run
 peary_config.cfgmatrix_mpw4.txtmpw4.conf 
  37   Sat Mar 30 11:04:10 2024 bp, ci, hhRD50-MPW41022RD50-MPW4800 MeVLow Flux LowProtonGood30.03.2024 11:03:0530.03.2024 11:06:373Normalautomatic log for run 1022
Comment:
changed alignment again
 peary_config.cfgmatrix_mpw4.txtmpw4.conf 
  38   Sat Mar 30 11:20:13 2024 bp, ci, hhRD50-MPW4 RD50-MPW4800 MeVLow Flux LowProtonGood   Normalalignment good now   
ELOG V3.1.5-fc6679b