ID Date Author Subject Run Number DUT Beam Energy Rate Settingdown Particle Type Data t-Start t-Stop Duration_min Frontend Text Attachments
  51   Sat Mar 30 15:31:41 2024 hh, mb, ps1st tests1034TJ-Monopix2800 MeVLow Flux LowProtonUnknown30.03.2024 15:29:4930.03.2024 15:34:084HVautomatic log for run 1034
Comment:
 tjmonopix2.conf 
  52   Sat Mar 30 15:39:06 2024 hh, mb, ps1st tests1035TJ-Monopix2800 MeVLow Flux LowProtonUnknown30.03.2024 15:35:0630.03.2024 15:41:336HVautomatic log for run 1035

All four chips enabled now
 tjmonopix2.conf 
  53   Sat Mar 30 15:51:21 2024 hh, mb, ps1st tests1036TJ-Monopix2800 MeVLow Flux LowProtonUnknown30.03.2024 15:43:5330.03.2024 15:53:479HVautomatic log for run 1036
Comment:
 tjmonopix2.conf 
  54   Sat Mar 30 15:55:32 2024 hh, mb, ps1st tests1037TJ-Monopix2800 MeVLow Flux LowProtonUnknown30.03.2024 15:54:4430.03.2024 15:57:593HVautomatic log for run 1037
Comment:
 tjmonopix2.conf 
  55   Sat Mar 30 16:03:35 2024 hh, mb, ps1st tests1038TJ-Monopix2800 MeVLow Flux LowProtonUnknown30.03.2024 16:03:1830.03.2024 16:06:012HVautomatic log for run 1038
Comment:
 tjmonopix2.conf 
  56   Sat Mar 30 16:09:54 2024 hh, mb, ps1st tests1039TJ-Monopix2800 MeVLow Flux LowProtonUnknown30.03.2024 16:11:3230.03.2024 16:12:210HVautomatic log for run 1039
Comment:
 tjmonopix2.conf 
  57   Sat Mar 30 16:15:20 2024 hh, mb, ps1st tests1040TJ-Monopix2800 MeVLow Flux LowProtonUnknown30.03.2024 16:15:2230.03.2024 16:17:462HVautomatic log for run 1040
Comment:
 tjmonopix2.conf 
  58   Sat Mar 30 16:24:39 2024 hh, mb, ps1st tests1041TJ-Monopix2800 MeVLow Flux LowProtonUnknown30.03.2024 16:20:3430.03.2024 16:27:056HVautomatic log for run 1041
Comment:
 tjmonopix2.conf 
  59   Sat Mar 30 16:38:41 2024 hh, mb, ps1st tests1042TJ-Monopix2800 MeVLow Flux LowProtonUnknown30.03.2024 16:32:1230.03.2024 16:41:088HVautomatic log for run 1042
Comment: First good run
 tjmonopix2.conf 
  60   Sat Mar 30 16:50:35 2024 hh, mb, ps1st tests1043TJ-Monopix2800 MeVLow Flux LowProtonUnknown30.03.2024 16:48:3930.03.2024 16:53:014HVautomatic log for run 1043
Comment:
 tjmonopix2.conf 
  61   Sat Mar 30 17:00:53 2024 hh, mb, ps1st tests1044TJ-Monopix2800 MeVLow Flux LowProtonUnknown30.03.2024 16:57:0830.03.2024 17:03:206HVautomatic log for run 1044
Comment:
 tjmonopix2.conf 
  62   Sat Mar 30 17:07:45 2024 hh, mb, ps1st tests1045TJ-Monopix2800 MeVLow Flux LowProtonUnknown30.03.2024 17:07:0130.03.2024 17:10:123HVautomatic log for run 1045
Comment:
 tjmonopix2.conf 
  63   Sat Mar 30 17:31:59 2024 hh, mb, psHigh statistics1046TJ-Monopix2800 MeVLow Flux LowProtonUnknown30.03.2024 17:13:0930.03.2024 17:34:2521HVautomatic log for run 1046
Comment:
High statistics run, from now we fix the
 tjmonopix2.conftestbench_AB.yamltestbench_CD.yaml 
  64   Sat Mar 30 18:59:16 2024 hh, mb, ps1st tests1047TJ-Monopix2800 MeVLow Flux LowProtonCrap30.03.2024 19:00:1130.03.2024 19:01:431HVautomatic log for run 1047
Comment:
Test if we get beam, MAUS has problems
 tjmonopix2.conf 
  70   Sat Mar 30 20:46:41 2024 hh, mb, psHigh statistics1053TJ-Monopix2800 MeVLow Flux HighProtonUnknown30.03.2024 20:31:1430.03.2024 20:49:0817HVautomatic log for run 1053
Comment:
Back to stock veto period of 7us (100)
 tjmonopix2.conf 
  71   Sat Mar 30 20:51:31 2024 hh, mb, psHigh statistics1054TJ-Monopix2800 MeVLow Flux HighProtonUnknown30.03.2024 20:50:5330.03.2024 20:53:583HVautomatic log for run 1054
Comment:
Litle high  settings run
 tjmonopix2.conf 
  72   Sat Jun 8 19:53:47 2024 Felix Ulrich-PurTOF CAL HADES LGADs Test High Rate1TOF-Cal GSI252.7 MeVLow Flux HighProtonGood16:0016:18  7.5 Mhz on Ramon (after 5 Layers of Silicon
and close to second iso centre) and 2.5 MHz
on LGAD
  
  80   Sat Jun 8 21:41:04 2024 Felix Ulrich-PurTOF CAL HADES LGADs Calibrationcurve9TOF-Cal GSI62.4 MeVLow Flux HighProtonGood20:5521:21  changed back to high due to beamsize vs
LGAD size factor
650 khz on Ramon (after 5 Layers of
  
  81   Sat Jun 8 21:42:13 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Wasser10TOF-Cal GSI194.3 MeVLow Flux HighProtonGood21:2721:39  1cm plastic water (in isocentre)
6 Mhz on Ramon (after 5 Layers of
Silicon and close to second iso centre) and
  
  82   Sat Jun 8 21:43:26 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Wasser11TOF-Cal GSI145.4 MeVLow Flux HighProtonGood21:3921:48  1cm plastic water (in isocentre)
4 Mhz on Ramon (after 5 Layers of
Silicon and close to second iso centre) and
  