Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024
  Testbeams at MedAustron in 2024, Page 4 of 5  Not logged in ELOG logo
ID Date Author Subjectdown Run Number DUT Beam Energy Rate Setting Particle Type Data t-Start t-Stop Duration_min Frontend
  28   Sat Mar 30 10:05:09 2024 bp, ci, hhRD50-MPW41015RD50-MPW4800 MeVLow Flux MediumProtonGood30.03.2024 10:02:1730.03.2024 10:07:365Normal
automatic log for run 1015
Comment:
changed rate
  29   Sat Mar 30 10:10:57 2024 bp, ci, hhRD50-MPW41016RD50-MPW4800 MeVLow Flux MediumProtonGood30.03.2024 10:07:5130.03.2024 10:13:235Normal
automatic log for run 1016
Comment:
changed rate
  30   Sat Mar 30 10:23:04 2024 bp, ci, hhRD50-MPW4 RD50-MPW4800 MeVLow Flux LowProtonGood   Normal
changed rate to low again, too much "noise"
also moved table down and a bit to the left
  31   Sat Mar 30 10:23:06 2024 bp, ci, hhRD50-MPW41017RD50-MPW4800 MeVLow Flux LowProtonCrap30.03.2024 10:25:0930.03.2024 10:25:330Normal
automatic log for run 1017
Comment:
changed rate to low again, too much "noise"
also moved table down and a bit to the left

no HV, is crap
  32   Sat Mar 30 10:25:55 2024 bp, ci, hhRD50-MPW41018RD50-MPW4800 MeVLow Flux LowProtonCrap30.03.2024 10:26:1730.03.2024 10:28:212Normal
automatic log for run 1018
Comment:
  33   Sat Mar 30 10:27:56 2024 bp, ci, hhRD50-MPW41019RD50-MPW4800 MeVLow Flux LowProtonCrap30.03.2024 10:28:2830.03.2024 10:30:221Normal
automatic log for run 1019
Comment:
  34   Sat Mar 30 10:28:42 2024 bp, ci, hhRD50-MPW4 RD50-MPW4800 MeVLow Flux LowProtonGood   Normal
tracker FADC down, HV not on earlier, restart happening
  35   Sat Mar 30 10:34:27 2024 bp, ci, hhRD50-MPW41020RD50-MPW4800 MeVLow Flux LowProtonGood30.03.2024 10:33:0130.03.2024 10:36:533Normal
automatic log for run 1020
Comment:
  36   Sat Mar 30 10:39:45 2024 bp, ci, hhRD50-MPW41021RD50-MPW4800 MeVLow Flux LowProtonGood30.03.2024 10:37:0130.03.2024 10:42:125Normal
automatic log for run 1021
Comment:
no tracker at start of run
  37   Sat Mar 30 11:04:10 2024 bp, ci, hhRD50-MPW41022RD50-MPW4800 MeVLow Flux LowProtonGood30.03.2024 11:03:0530.03.2024 11:06:373Normal
automatic log for run 1022
Comment:
changed alignment again
  38   Sat Mar 30 11:20:13 2024 bp, ci, hhRD50-MPW4 RD50-MPW4800 MeVLow Flux LowProtonGood   Normal
alignment good now
  63   Sat Mar 30 17:31:59 2024 hh, mb, psHigh statistics1046TJ-Monopix2800 MeVLow Flux LowProtonUnknown30.03.2024 17:13:0930.03.2024 17:34:2521HV
automatic log for run 1046
Comment:
High statistics run, from now we fix the geometry

Veto: 7us (100, so 7 us is handshake time)
  65   Sat Mar 30 19:24:57 2024 hh, mb, psHigh statistics1048TJ-Monopix2800 MeVLow Flux MediumProtonUnknown30.03.2024 19:02:5230.03.2024 19:27:2424HV
automatic log for run 1048
Comment:
Run with medium settings
  66   Sat Mar 30 19:36:57 2024 hh, mb, psHigh statistics1049TJ-Monopix2800 MeVLow Flux MediumProtonUnknown30.03.2024 19:28:4430.03.2024 19:39:2410HV
automatic log for run 1049
Comment:
Try with increased veto period of 20us (800)
  67   Sat Mar 30 19:44:43 2024 hh, mb, psHigh statistics1050TJ-Monopix2800 MeVLow Flux MediumProtonUnknown30.03.2024 19:40:2130.03.2024 19:47:106HV
automatic log for run 1050
Comment:
Try with increased veto period of 20us (800)
  68   Sat Mar 30 20:13:29 2024 hh, mb, psHigh statistics1051TJ-Monopix2800 MeVLow Flux MediumProtonUnknown30.03.2024 19:48:3630.03.2024 20:15:5527HV
automatic log for run 1051
Comment:
Try with increased veto period of 20us (800)
  69   Sat Mar 30 20:27:35 2024 hh, mb, psHigh statistics1052TJ-Monopix2800 MeVLow Flux MediumProtonUnknown30.03.2024 20:17:1130.03.2024 20:30:0212HV
automatic log for run 1052
Comment:
Back to stock veto period of 7us (100)
  70   Sat Mar 30 20:46:41 2024 hh, mb, psHigh statistics1053TJ-Monopix2800 MeVLow Flux HighProtonUnknown30.03.2024 20:31:1430.03.2024 20:49:0817HV
automatic log for run 1053
Comment:
Back to stock veto period of 7us (100)
Lets try with high
  71   Sat Mar 30 20:51:31 2024 hh, mb, psHigh statistics1054TJ-Monopix2800 MeVLow Flux HighProtonUnknown30.03.2024 20:50:5330.03.2024 20:53:583HV
automatic log for run 1054
Comment:
Litle high settings run
  1   Sat Mar 30 06:34:39 2024 Bernhard PilslAnd a new testbeam starts :D          
ELOG V3.1.5-fc6679b