ID |
Date |
Author |
Subject |
Run Number |
DUT |
Beam Energy |
Rate Setting |
Particle Type |
Data |
t-Start |
t-Stop |
Duration_min |
Frontend |
62
|
Sat Mar 30 17:07:45 2024 |
hh, mb, ps | 1st tests | 1045 | TJ-Monopix2 | 800 MeV | Low Flux Low | Proton | Unknown | 30.03.2024 17:07:01 | 30.03.2024 17:10:12 | 3 | HV |
automatic log for run 1045
Comment: |
63
|
Sat Mar 30 17:31:59 2024 |
hh, mb, ps | High statistics | 1046 | TJ-Monopix2 | 800 MeV | Low Flux Low | Proton | Unknown | 30.03.2024 17:13:09 | 30.03.2024 17:34:25 | 21 | HV |
automatic log for run 1046
Comment:
High statistics run, from now we fix the geometry
Veto: 7us (100, so 7 us is handshake time) |
64
|
Sat Mar 30 18:59:16 2024 |
hh, mb, ps | 1st tests | 1047 | TJ-Monopix2 | 800 MeV | Low Flux Low | Proton | Crap | 30.03.2024 19:00:11 | 30.03.2024 19:01:43 | 1 | HV |
automatic log for run 1047
Comment:
Test if we get beam, MAUS has problems |
65
|
Sat Mar 30 19:24:57 2024 |
hh, mb, ps | High statistics | 1048 | TJ-Monopix2 | 800 MeV | Low Flux Medium | Proton | Unknown | 30.03.2024 19:02:52 | 30.03.2024 19:27:24 | 24 | HV |
automatic log for run 1048
Comment:
Run with medium settings |
66
|
Sat Mar 30 19:36:57 2024 |
hh, mb, ps | High statistics | 1049 | TJ-Monopix2 | 800 MeV | Low Flux Medium | Proton | Unknown | 30.03.2024 19:28:44 | 30.03.2024 19:39:24 | 10 | HV |
automatic log for run 1049
Comment:
Try with increased veto period of 20us (800) |
67
|
Sat Mar 30 19:44:43 2024 |
hh, mb, ps | High statistics | 1050 | TJ-Monopix2 | 800 MeV | Low Flux Medium | Proton | Unknown | 30.03.2024 19:40:21 | 30.03.2024 19:47:10 | 6 | HV |
automatic log for run 1050
Comment:
Try with increased veto period of 20us (800) |
68
|
Sat Mar 30 20:13:29 2024 |
hh, mb, ps | High statistics | 1051 | TJ-Monopix2 | 800 MeV | Low Flux Medium | Proton | Unknown | 30.03.2024 19:48:36 | 30.03.2024 20:15:55 | 27 | HV |
automatic log for run 1051
Comment:
Try with increased veto period of 20us (800) |
69
|
Sat Mar 30 20:27:35 2024 |
hh, mb, ps | High statistics | 1052 | TJ-Monopix2 | 800 MeV | Low Flux Medium | Proton | Unknown | 30.03.2024 20:17:11 | 30.03.2024 20:30:02 | 12 | HV |
automatic log for run 1052
Comment:
Back to stock veto period of 7us (100) |
70
|
Sat Mar 30 20:46:41 2024 |
hh, mb, ps | High statistics | 1053 | TJ-Monopix2 | 800 MeV | Low Flux High | Proton | Unknown | 30.03.2024 20:31:14 | 30.03.2024 20:49:08 | 17 | HV |
automatic log for run 1053
Comment:
Back to stock veto period of 7us (100)
Lets try with high |
71
|
Sat Mar 30 20:51:31 2024 |
hh, mb, ps | High statistics | 1054 | TJ-Monopix2 | 800 MeV | Low Flux High | Proton | Unknown | 30.03.2024 20:50:53 | 30.03.2024 20:53:58 | 3 | HV |
automatic log for run 1054
Comment:
Litle high settings run |
80
|
Sat Jun 8 21:41:04 2024 |
Felix Ulrich-Pur | TOF CAL HADES LGADs Calibrationcurve | 9 | TOF-Cal GSI | 62.4 MeV | Low Flux High | Proton | Good | 20:55 | 21:21 | | |
changed back to high due to beamsize vs LGAD size factor
650 khz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 230kHz on LGAD
TOF Calibration Curve |
72
|
Sat Jun 8 19:53:47 2024 |
Felix Ulrich-Pur | TOF CAL HADES LGADs Test High Rate | 1 | TOF-Cal GSI | 252.7 MeV | Low Flux High | Proton | Good | 16:00 | 16:18 | | |
7.5 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 2.5 MHz on LGAD |
73
|
Sat Jun 8 19:56:37 2024 |
Felix Ulrich-Pur | TOF CAL HADES LGADs Calibrationcurve | 2 | TOF-Cal GSI | 252.7 MeV | Low Flux Medium | Proton | Good | 16:29 | 16:47 | | |
1 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 350kHz on LGAD
TOF Calibration Curve |
74
|
Sat Jun 8 19:57:39 2024 |
Felix Ulrich-Pur | TOF CAL HADES LGADs Calibrationcurve | 3 | TOF-Cal GSI | 194.3 MeV | Low Flux Medium | Proton | Good | 16:51 | 17:28 | | |
600 khz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 235kHz on LGAD
TOF Calibration Curve |
81
|
Sat Jun 8 21:42:13 2024 |
Felix Ulrich-Pur | TOF CAL HADES LGADs WET Messung Wasser | 10 | TOF-Cal GSI | 194.3 MeV | Low Flux High | Proton | Good | 21:27 | 21:39 | | |
1cm plastic water (in isocentre)
6 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 1.5 MHz on LGAD
WET measurement |
83
|
Sat Jun 8 21:54:59 2024 |
Felix Ulrich-Pur | TOF CAL HADES LGADs WET Messung Wasser | 12 | TOF-Cal GSI | 194.3 MeV | Low Flux High | Proton | Good | 21:53 | 22:05 | | |
2cm plastic water (in isocentre)
5 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 1.2 MHz on LGAD
WET measurement |
85
|
Sat Jun 8 22:38:41 2024 |
Felix Ulrich-Pur | TOF CAL HADES LGADs WET Messung Wasser | 14 | TOF-Cal GSI | 194.3 MeV | Low Flux High | Proton | Good | 22:19 | 22.34 | | |
3 cm plastic water (in isocentre)
4.3 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 1MHz on LGAD
WET measurement |
86
|
Sun Jun 9 00:04:23 2024 |
Felix Ulrich-Pur | TOF CAL HADES LGADs WET Messung Wasser | 15 | TOF-Cal GSI | 194.3 MeV | Low Flux High | Proton | Good | 22:34 | 22:50 | | |
3 cm plastic water (in isocentre)
2.6 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 400 kHz on LGAD
WET measurement |
87
|
Sun Jun 9 00:05:11 2024 |
Felix Ulrich-Pur | TOF CAL HADES LGADs WET Messung Wasser (wrong energy) | 16 | TOF-Cal GSI | 194.3 MeV | Low Flux High | Proton | Crap | 22:50 | 22:52 | | |
wrong energy don't use |
88
|
Sun Jun 9 00:06:01 2024 |
Felix Ulrich-Pur | TOF CAL HADES LGADs WET Messung Wasser | 17 | TOF-Cal GSI | 194.3 MeV | Low Flux High | Proton | Good | 22:53 | 23:04 | | |
4 cm plastic water (in isocentre)
3.8 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 900 kHz on LGAD
WET measurement |