Sat Jun 8 20:08:55 2024, Felix Ulrich-Pur, TOF CAL HADES LGADs Calibrationcurve, 6, TOF-Cal GSI, 115.7MeV, Low Flux Medium, Proton, Good, 18:24, 19:00, , , ,
|
400 khz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 65kHz on LGAD
TOF Calibration Curve |
Sat Dec 14 12:54:55 2024, Felix Ulrich-Pur, Shift 23.11.24 low flux He test with RaMon, 6, RaMon, 73.2 MeV/u, Low Flux Medium, Helium, Good, 06:34, 06:34, 1, , ,
|
Mean rate per spill~ 4.5-8E5 p/s (online estimation without proper analysis) |
Sun Aug 25 10:06:51 2024, tb-crew, only base, 59, RD50-MPW4, 800 MeV, Low Flux Very Low, Proton, Crap, 25.08.2024 10:05:01, 25.08.2024 10:07:18, 2, Normal, ,
|
automatic log for run 59
Comment:
reducing base threshold |
Sat Dec 14 15:39:11 2024, Felix Ulrich-Pur, plastic mouse radiography, 59, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 97.2MeV/u, Low Flux High, Helium, Good, 23:33, 23:46, 13, , plastic mouse,
|
pos x=-175, posy=-75
TRB Setup: 260V bias and 250mA pre-amps, threshold 5000
Diamond: 900mA, threshold 1000 offset |
Sun Aug 25 09:47:51 2024, tb-crew, VNFB scan, 58, RD50-MPW4, 800 MeV, Low Flux Very Low, Proton, Unknown, 25.08.2024 09:37:13, 25.08.2024 09:48:18, 11, Normal, ,
|
automatic log for run 58
Comment:
vnfb = 60 |
Sat Dec 14 15:37:48 2024, Felix Ulrich-Pur, plastic mouse radiography, 58, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 97.2MeV/u, Low Flux High, Helium, Good, 23:17, 23:30, 13, , plastic mouse,
|
pos x=-175, posy=0
TRB Setup: 260V bias and 250mA pre-amps, threshold 5000
Diamond: 900mA, threshold 1000 offset |
Sun Aug 25 09:35:54 2024, tb-crew, VNFB scan, 57, RD50-MPW4, 800 MeV, Low Flux Very Low, Proton, Unknown, 25.08.2024 09:25:43, 25.08.2024 09:36:22, 10, Normal, ,
|
automatic log for run 57
Comment:
vnfb = 50 |
Sat Dec 14 15:37:26 2024, Felix Ulrich-Pur, plastic mouse radiography, 57, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 97.2MeV/u, Low Flux High, Helium, Good, 23:02, 23:16, 14, , plastic mouse,
|
pos x=-100, posy=0
TRB Setup: 260V bias and 250mA pre-amps, threshold 5000
Diamond: 900mA, threshold 1000 offset |
Sun Aug 25 09:24:15 2024, tb-crew, VNFB scan, 56, RD50-MPW4, 800 MeV, Low Flux Very Low, Proton, Unknown, 25.08.2024 09:13:35, 25.08.2024 09:24:42, 11, Normal, ,
|
automatic log for run 56
Comment:
vnfb = 40 |
Sat Dec 14 15:36:37 2024, Felix Ulrich-Pur, plastic mouse radiography, 56, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 97.2MeV/u, Low Flux High, Helium, Good, 22:46, 23:00, 14, , plastic mouse,
|
pos x=-25, posy=0
TRB Setup: 260V bias and 250mA pre-amps, threshold 5000
Diamond: 900mA, threshold 1000 offset |
Sun Aug 25 09:12:07 2024, tb-crew, VNFB scan, 55, RD50-MPW4, 800 MeV, Low Flux Very Low, Proton, Unknown, 25.08.2024 09:01:26, 25.08.2024 09:12:34, 11, Normal, ,
|
automatic log for run 55
Comment:
vnfb = 30 |
Sat Dec 14 15:35:56 2024, Felix Ulrich-Pur, plastic mouse radiography, 55, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 97.2MeV/u, Low Flux High, Helium, Good, 22:12, 22:45, 33, , plastic mouse,
|
pos x=25, posy=0
TRB Setup: 260V bias and 250mA pre-amps, threshold 5000
Diamond: 900mA, threshold 1000 offset |
Sun Aug 25 08:59:46 2024, tb-crew, VNFB scan, 54, RD50-MPW4, 800 MeV, Low Flux Very Low, Proton, Unknown, 25.08.2024 08:53:16, 25.08.2024 09:00:13, 6, Normal, ,
|
automatic log for run 54
Comment:
vnfb = 20 |
Sat Dec 14 15:34:50 2024, Felix Ulrich-Pur, plastic mouse radiography, 54, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 97.2MeV/u, Low Flux High, Helium, Good, 21:58, 22:10, 22, , plastic mouse,
|
pos x=100, posy=0
TRB Setup: 260V bias and 250mA pre-amps, threshold 5000
Diamond: 900mA, threshold 1000 offset |
Sun Aug 25 08:51:02 2024, tb-crew, VNFB scan, 53, RD50-MPW4, 800 MeV, Low Flux Very Low, Proton, Unknown, 25.08.2024 08:36:24, 25.08.2024 08:51:28, 15, Normal, ,
|
automatic log for run 53
Comment:
vnfb = 10 |
Sat Dec 14 15:33:35 2024, Felix Ulrich-Pur, plastic mouse radiography, 53, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 97.2MeV/u, Low Flux High, Helium, Good, 21:33, 21:57, 24, , plastic mouse,
|
run 52 was crap
pos x=175, posy=0
TRB Setup: 260V bias and 250mA pre-amps, threshold 5000 |
Sun Aug 25 08:33:56 2024, tb-crew, Piggy test, 52, RD50-MPW4, 800 MeV, Low Flux Very Low, Proton, Unknown, 25.08.2024 08:11:40, 25.08.2024 08:34:23, 22, Normal, ,
|
automatic log for run 52
Comment: |
Sun Aug 25 08:10:54 2024, tb-crew, Piggy test, 51, RD50-MPW4, 800 MeV, Low Flux Very Low, Proton, Unknown, 25.08.2024 07:45:15, 25.08.2024 08:11:20, 26, Normal, ,
|
automatic log for run 51
Comment:
stuck again? |
Sat Dec 14 15:31:32 2024, Felix Ulrich-Pur, plastic mouse radiography, 51, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 97.2MeV/u, Low Flux High, Helium, Good, 21:14, 21:30, 16, , plastic mouse,
|
before run, mouse was aligned with lasers and shift of beam w.r.t. sensor center was taken into account
pos x=250, posy=0
TRB Setup: 260V bias and 250mA pre-amps, threshold 5000 |
Sun Aug 25 07:43:36 2024, tb-crew, Piggy test, 50, RD50-MPW4, 800 MeV, Low Flux Very Low, Proton, Unknown, 25.08.2024 07:19:46, 25.08.2024 07:44:03, 24, Normal, ,
|
automatic log for run 50
Comment: |
|