Sat Mar 30 08:05:59 2024, Christian Irmler, RD50-MPW4, 999, , , , , , , , , , ,
|
Tracker calibration run: mpw4-tj-monopix2_00-000999.xml
Generated global xml file for MPW4 shift: mpw4-tj-monopix2_TLU_00-000999.xml
Previous local runs and xml files (mpw4-tj-monopix2_00-000212.xml) are unusable, because sensor L5.1.1.0 had a loose cotact and thus low gain. |
Sat Jun 8 21:41:04 2024, Felix Ulrich-Pur, TOF CAL HADES LGADs Calibrationcurve, 9, TOF-Cal GSI, 62.4 MeV, Low Flux High, Proton, Good, 20:55, 21:21, , , ,
|
changed back to high due to beamsize vs LGAD size factor
650 khz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 230kHz on LGAD
TOF Calibration Curve |
Sat Dec 14 12:56:38 2024, Felix Ulrich-Pur, Shift 23.11.24 low flux He test with RaMon, 9, RaMon, 177.8 MeV/u, Low Flux High, Helium, Good, 06:40, 06:41, 1, , ,
|
Mean rate per spill~ 4.5e6 p/s (online estimation without proper analysis) |
Sat Dec 14 15:50:19 2024, Felix Ulrich-Pur, LGAD+Diamond test with clinical carbon beam, 80, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 402MeV/u, , Carbon, Good, 05:15, 05:50, 35, , ,
|
Carbon Deg10 (clinical rate)
TRB Setup: 260V bias and 250mA pre-amps, threshold 5000
Diamond: 900mA, threshold 1000 offset |
Sat Jun 8 20:11:00 2024, Felix Ulrich-Pur, TOF CAL HADES LGADs Calibrationcurve, 8, TOF-Cal GSI, 83 MeV, Low Flux Medium, Proton, Good, 19:42, 20:51, , , ,
|
300 khz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 35kHz on LGAD
TOF Calibration Curve |
Sat Dec 14 12:56:05 2024, Felix Ulrich-Pur, Shift 23.11.24 low flux He test with RaMon, 8, RaMon, 205.2 MeV/u, Low Flux High, Helium, Good, 06:39, 06:40, 1, , ,
|
Mean rate per spill~ 5e6 p/s (online estimation without proper analysis) |
Sat Dec 14 15:49:58 2024, Felix Ulrich-Pur, plastic mouse radiography, 79, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 97.2MeV/u, Low Flux High, Helium, Good, 04:51, 05:05, 14, , plastic mouse,
|
pos x=250, posy=-175
TRB Setup: 260V bias and 250mA pre-amps, threshold 5000
Diamond: 900mA, threshold 1000 offset |
Sat Dec 14 15:49:32 2024, Felix Ulrich-Pur, plastic mouse radiography, 78, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 97.2MeV/u, Low Flux High, Helium, Good, 04:36, 04:50, 14, , plastic mouse,
|
pos x=175, posy=-175
TRB Setup: 260V bias and 250mA pre-amps, threshold 5000
Diamond: 900mA, threshold 1000 offset |
Sat Dec 14 15:49:12 2024, Felix Ulrich-Pur, plastic mouse radiography, 77, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 97.2MeV/u, Low Flux High, Helium, Good, 04:22, 04:36, 14, , plastic mouse,
|
pos x=100, posy=-175
TRB Setup: 260V bias and 250mA pre-amps, threshold 5000
Diamond: 900mA, threshold 1000 offset |
Sat Dec 14 15:48:49 2024, Felix Ulrich-Pur, plastic mouse radiography, 76, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 97.2MeV/u, Low Flux High, Helium, Good, 04:06, 04:21, 15, , plastic mouse,
|
pos x=25, posy=-175
TRB Setup: 260V bias and 250mA pre-amps, threshold 5000
Diamond: 900mA, threshold 1000 offset |
Sat Dec 14 15:48:26 2024, Felix Ulrich-Pur, plastic mouse radiography, 75, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 97.2MeV/u, Low Flux High, Helium, Good, 03:52, 04:05, 13, , plastic mouse,
|
pos x=-25, posy=-175
TRB Setup: 260V bias and 250mA pre-amps, threshold 5000
Diamond: 900mA, threshold 1000 offset |
Sat Dec 14 15:47:59 2024, Felix Ulrich-Pur, plastic mouse radiography, 74, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 97.2MeV/u, Low Flux High, Helium, Good, 03:35, 03:51, 16, , plastic mouse,
|
pos x=-100, posy=-175
TRB Setup: 260V bias and 250mA pre-amps, threshold 5000
Diamond: 900mA, threshold 1000 offset |
Sat Dec 14 15:47:29 2024, Felix Ulrich-Pur, plastic mouse radiography, 73, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 97.2MeV/u, Low Flux High, Helium, Good, 03:20, 03:55, 25, , plastic mouse,
|
pos x=-175, posy=-175
TRB Setup: 260V bias and 250mA pre-amps, threshold 5000
Diamond: 900mA, threshold 1000 offset |
Sat Dec 14 15:46:54 2024, Felix Ulrich-Pur, plastic mouse radiography, 72, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 97.2MeV/u, Low Flux High, Helium, Good, 03:03, 03:19, 16, , plastic mouse,
|
pos x=-175, posy=75
TRB Setup: 260V bias and 250mA pre-amps, threshold 5000
Diamond: 900mA, threshold 1000 offset |
Sun Aug 25 12:51:10 2024, tb-crew, only base, 71, RD50-MPW4, 62.4 MeV, Low Flux Very Low, Proton, Unknown, 25.08.2024 12:40:41, 25.08.2024 12:51:37, 10, Normal, ,
|
automatic log for run 71
Comment:
E-scan |
Sat Dec 14 15:46:16 2024, Felix Ulrich-Pur, plastic mouse radiography, 71, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 97.2MeV/u, Low Flux High, Helium, Good, 02:46, 03:03, 17, , plastic mouse,
|
pos x=-100, posy=75
TRB Setup: 260V bias and 250mA pre-amps, threshold 5000
Diamond: 900mA, threshold 1000 offset |
Sun Aug 25 12:39:45 2024, tb-crew, only base, 70, RD50-MPW4, 100.4 MeV, Low Flux Very Low, Proton, Unknown, 25.08.2024 12:24:36, 25.08.2024 12:40:12, 15, Normal, ,
|
automatic log for run 70
Comment:
E-scan |
Sat Dec 14 15:45:36 2024, Felix Ulrich-Pur, plastic mouse radiography, 70, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 97.2MeV/u, Low Flux High, Helium, Good, 02:25, 02:45, 20, , plastic mouse,
|
pos x=-25, posy=75
TRB Setup: 260V bias and 250mA pre-amps, threshold 5000
Diamond: 900mA, threshold 1000 offset |
Sat Jun 8 20:09:25 2024, Felix Ulrich-Pur, TOF CAL HADES LGADs Calibrationcurve, 7, TOF-Cal GSI, 100.4 MeV, Low Flux Medium, Proton, Good, 19:00, 19:42, , , ,
|
300 khz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 65kHz on LGAD
TOF Calibration Curve |
Sat Dec 14 12:55:41 2024, Felix Ulrich-Pur, Shift 23.11.24 low flux He test with RaMon, 7, RaMon, 63.3 MeV/u, Low Flux Medium, Helium, Good, 06:35, 06:36, 1, , ,
|