ID |
Date |
Author |
Subject |
Run Number |
DUT |
Beam Energy |
Rate Setting |
Particle Type |
Data |
t-Start |
t-Stop |
Duration_min |
Frontend |
Phantom |
Phantom thickness |
Text |
|
210
|
Sat Dec 14 15:46:54 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 72 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 03:03 | 03:19 | 16 | | plastic mouse | | pos x=-175, posy=75
TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000 |
|
211
|
Sat Dec 14 15:47:29 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 73 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 03:20 | 03:55 | 25 | | plastic mouse | | pos x=-175, posy=-175
TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000 |
|
212
|
Sat Dec 14 15:47:59 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 74 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 03:35 | 03:51 | 16 | | plastic mouse | | pos x=-100, posy=-175
TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000 |
|
213
|
Sat Dec 14 15:48:26 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 75 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 03:52 | 04:05 | 13 | | plastic mouse | | pos x=-25, posy=-175
TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000 |
|
214
|
Sat Dec 14 15:48:49 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 76 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 04:06 | 04:21 | 15 | | plastic mouse | | pos x=25, posy=-175
TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000 |
|
215
|
Sat Dec 14 15:49:12 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 77 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 04:22 | 04:36 | 14 | | plastic mouse | | pos x=100, posy=-175
TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000 |
|
216
|
Sat Dec 14 15:49:32 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 78 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 04:36 | 04:50 | 14 | | plastic mouse | | pos x=175, posy=-175
TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000 |
|
217
|
Sat Dec 14 15:49:58 2024 |
Felix Ulrich-Pur | plastic mouse radiography | 79 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 04:51 | 05:05 | 14 | | plastic mouse | | pos x=250, posy=-175
TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000 |
|
168
|
Sat Dec 14 13:46:11 2024 |
Felix Ulrich-Pur | WET measurement slabs | 29 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 205.2 MeV/u | Low Flux High | Helium | Good | 13:34 | 14:03 | 29 | | Plastic Water Slabs | 1cm | 1cm Plastic Water
TRB Setup: 260V bias and 250mA
pre-amps, threshold 1000 (changed threshold) |
|
169
|
Sat Dec 14 13:49:20 2024 |
Felix Ulrich-Pur | WET measurement slabs | 30 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 147.2 MeV/u | Low Flux High | Helium | Good | 14:02 | 14:45 | 43 | | Plastic Water Slabs | 1cm | 1cm plastic water
TRB Setup: 260V bias and 250mA
pre-amps, threshold 1000 |
|
170
|
Sat Dec 14 13:56:16 2024 |
Felix Ulrich-Pur | WET measurement slabs | 31 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 205.2 MeV/u | Low Flux High | Helium | Good | 14:48 | 15:06 | 18 | | Plastic Water Slabs | 2cm | 2cm plastic water
TRB Setup: 260V bias and 250mA
pre-amps, threshold 1000 |
|
171
|
Sat Dec 14 15:09:34 2024 |
Felix Ulrich-Pur | WET measurement slabs | 32 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 147.2 MeV/u | Low Flux High | Helium | Good | 15:06 | 15:19 | 13 | | Plastic Water Slabs | 2cm | 2cm plastic water
TRB Setup: 260V bias and 250mA
pre-amps, threshold 1000 |
|
172
|
Sat Dec 14 15:10:35 2024 |
Felix Ulrich-Pur | WET measurement slabs | 33 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 205.2 MeV/u | Low Flux High | Helium | Good | 15:24 | 15:36 | 12 | | Plastic Water Slabs | 3cm | 3cm plastic water
TRB Setup: 260V bias and 250mA
pre-amps, threshold 1000 |
|
173
|
Sat Dec 14 15:12:01 2024 |
Felix Ulrich-Pur | WET measurement slabs | 34 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 147.2 MeV/u | Low Flux High | Helium | Good | 15:37 | 15:48 | 11 | | Plastic Water Slabs | 3cm | 3cm plastic water
TRB Setup: 260V bias and 250mA
pre-amps, threshold 1000 |
|
174
|
Sat Dec 14 15:12:46 2024 |
Felix Ulrich-Pur | WET measurement slabs | 35 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 205.2 MeV/u | Low Flux High | Helium | Good | 15:53 | 16:10 | 17 | | Plastic Water Slabs | 4cm | 4cm plastic water
TRB Setup: 260V bias and 250mA
pre-amps, threshold 1000 |
|
175
|
Sat Dec 14 15:15:04 2024 |
Felix Ulrich-Pur | WET measurement slabs | 36 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 147.2 MeV/u | Low Flux High | Helium | Good | 16:11 | 16:23 | 12 | | Plastic Water Slabs | 4cm | 4cm plastic water
TRB Setup: 260V bias and 250mA
pre-amps, threshold 1000 |
|
176
|
Sat Dec 14 15:15:46 2024 |
Felix Ulrich-Pur | WET measurement slabs | 37 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 205.2 MeV/u | Low Flux High | Helium | Good | 16:28 | 16:42 | 12 | | Plastic Water Slabs | 5cm | 5cm plastic water
TRB Setup: 260V bias and 250mA
pre-amps, threshold 1000 |
|
177
|
Sat Dec 14 15:17:10 2024 |
Felix Ulrich-Pur | WET measurement slabs | 38 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 147.2 MeV/u | Low Flux High | Helium | Good | 16:42 | 16:55 | 13 | | Plastic Water Slabs | 5cm | 5cm plastic water
TRB Setup: 260V bias and 250mA
pre-amps, threshold 1000 |
|
178
|
Sat Dec 14 15:17:57 2024 |
Felix Ulrich-Pur | WET measurement slabs | 39 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 205.2 MeV/u | Low Flux High | Helium | Good | 17:00 | 17:14 | 13 | | Dense Bone Slabs | 1cm | 1cm dense bone
TRB Setup: 260V bias and 250mA
pre-amps, threshold 1000 |
|
179
|
Sat Dec 14 15:18:48 2024 |
Felix Ulrich-Pur | WET measurement slabs | 40 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 147.2 MeV/u | Low Flux High | Helium | Good | 17:14 | 17:28 | 14 | | Dense Bone Slabs | 1cm | 1cm dense bone
TRB Setup: 260V bias and 250mA
pre-amps, threshold 1000 |
|