Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024
  Testbeams at MedAustron in 2024, Page 2 of 11  Not logged in ELOG logo
New entries since:Thu Jan 1 01:00:00 1970
ID Date Author Subject Run Number DUT Beam Energy Rate Setting Particle Type Data t-Start t-Stop Duration_mindown Frontend Phantom Phantom thickness Text Attachments
  159   Sat Dec 14 13:28:57 2024 Felix Ulrich-PurEnergy vs TOF calibration20TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon147.2 MeV/uLow Flux MediumHeliumGood10:3310:385   TRB Setup: 260V bias and 250mA pre-amps,
threshold 1000

300kHz with Ramon and only 40kHz
  
  188   Sat Dec 14 15:28:46 2024 Felix Ulrich-Purthreshold and preamp tests49TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood20:0420:095   TRB Setup: 260V bias and 250mA pre-amps,
threshold 10000 (was too high)

Diamond: 900mA, threshold 1000
  
  169   Sat Dec 14 13:49:20 2024 Felix Ulrich-PurWET measurement slabs30TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon147.2 MeV/uLow Flux HighHeliumGood14:0214:4543 Plastic Water Slabs1cm1cm plastic water

TRB Setup: 260V bias and 250mA
pre-amps, threshold 1000
  
  4   Sat Mar 30 07:00:10 2024 bp, ci, hhRD50-MPW41001RD50-MPW4800 MeVLow Flux Very LowProtonUnknown30.03.2024 06:58:0330.03.2024 07:02:364Normal  automatic log for run 1001
Comment:
1st test runs
 peary_config.cfgmatrix_mpw4.txtmpw4.conf 
  51   Sat Mar 30 15:31:41 2024 hh, mb, ps1st tests1034TJ-Monopix2800 MeVLow Flux LowProtonUnknown30.03.2024 15:29:4930.03.2024 15:34:084HV  automatic log for run 1034
Comment:
 tjmonopix2.conf 
  60   Sat Mar 30 16:50:35 2024 hh, mb, ps1st tests1043TJ-Monopix2800 MeVLow Flux LowProtonUnknown30.03.2024 16:48:3930.03.2024 16:53:014HV  automatic log for run 1043
Comment:
 tjmonopix2.conf 
  218   Sat Dec 14 15:50:19 2024 Felix Ulrich-PurLGAD+Diamond test with clinical carbon beam80TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon402MeV/u CarbonGood05:1505:5035   Carbon Deg10 (clinical rate)

TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000
  
  193   Sat Dec 14 15:35:56 2024 Felix Ulrich-Purplastic mouse radiography55TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood22:1222:4533 plastic mouse pos x=25, posy=0

TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000
  
  40   Sat Mar 30 12:28:29 2024 bp, ci, hhuseful datataking1024RD50-MPW4800 MeVLow Flux LowProtonGood30.03.2024 11:58:4530.03.2024 12:30:5632Normal  automatic log for run 1024
Comment:
changed thr to 1V (not 100% sure, configure
 peary_config.cfgmatrix_mpw4.txtmpw4.conf 
  42   Sat Mar 30 13:28:15 2024 bp, ci, hhuseful datataking1026RD50-MPW4800 MeVLow Flux LowProtonGood30.03.2024 12:58:0230.03.2024 13:30:4232Normal  automatic log for run 1026
Comment:
changed thr to 0.98V
 peary_config.cfgmatrix_mpw4.txtmpw4.conf 
  35   Sat Mar 30 10:34:27 2024 bp, ci, hhRD50-MPW41020RD50-MPW4800 MeVLow Flux LowProtonGood30.03.2024 10:33:0130.03.2024 10:36:533Normal  automatic log for run 1020
Comment:
 peary_config.cfgmatrix_mpw4.txtmpw4.conf 
  37   Sat Mar 30 11:04:10 2024 bp, ci, hhRD50-MPW41022RD50-MPW4800 MeVLow Flux LowProtonGood30.03.2024 11:03:0530.03.2024 11:06:373Normal  automatic log for run 1022
Comment:
changed alignment again
 peary_config.cfgmatrix_mpw4.txtmpw4.conf 
  45   Sat Mar 30 15:05:28 2024 hh, mb, ps1st tests1028TJ-Monopix2800 MeVLow Flux LowProtonUnknown30.03.2024 15:04:4730.03.2024 15:07:553HV  automatic log for run 1028
Comment:
 tjmonopix2.conf 
  54   Sat Mar 30 15:55:32 2024 hh, mb, ps1st tests1037TJ-Monopix2800 MeVLow Flux LowProtonUnknown30.03.2024 15:54:4430.03.2024 15:57:593HV  automatic log for run 1037
Comment:
 tjmonopix2.conf 
  62   Sat Mar 30 17:07:45 2024 hh, mb, ps1st tests1045TJ-Monopix2800 MeVLow Flux LowProtonUnknown30.03.2024 17:07:0130.03.2024 17:10:123HV  automatic log for run 1045
Comment:
 tjmonopix2.conf 
  71   Sat Mar 30 20:51:31 2024 hh, mb, psHigh statistics1054TJ-Monopix2800 MeVLow Flux HighProtonUnknown30.03.2024 20:50:5330.03.2024 20:53:583HV  automatic log for run 1054
Comment:
Litle high  settings run
 tjmonopix2.conf 
  168   Sat Dec 14 13:46:11 2024 Felix Ulrich-PurWET measurement slabs29TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon205.2 MeV/uLow Flux HighHeliumGood13:3414:0329 Plastic Water Slabs1cm1cm Plastic Water

TRB Setup: 260V bias and 250mA
pre-amps, threshold 1000 (changed threshold)
  
  68   Sat Mar 30 20:13:29 2024 hh, mb, psHigh statistics1051TJ-Monopix2800 MeVLow Flux MediumProtonUnknown30.03.2024 19:48:3630.03.2024 20:15:5527HV  automatic log for run 1051
Comment:
Try with increased veto period of 20us (800)
 tjmonopix2.conf 
  114   Sun Aug 25 08:10:54 2024 tb-crewPiggy test51RD50-MPW4800 MeVLow Flux Very LowProtonUnknown25.08.2024 07:45:1525.08.2024 08:11:2026Normal  automatic log for run 51
Comment:
stuck again?
 peary_config.cfgmatrix_mpw4_base.txtmatrix_mpw4_piggy.txtmpw4.conf 
  161   Sat Dec 14 13:34:18 2024 Felix Ulrich-PurEnergy vs TOF calibration21TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood10:5811:2325   TRB Setup: 260V bias and 250mA pre-amps,
threshold 1000

3MHz with Ramon and only 300kHz
  
ELOG V3.1.5-fc6679b