Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024
  Testbeams at MedAustron in 2024, Page 2 of 5  Not logged in ELOG logo
ID Date Author Subject Run Number DUT Beam Energy Rate Setting Particle Type Datadown t-Start t-Stop Duration_min Frontend
  57   Sat Mar 30 16:15:20 2024 hh, mb, ps1st tests1040TJ-Monopix2800 MeVLow Flux LowProtonUnknown30.03.2024 16:15:2230.03.2024 16:17:462HV
automatic log for run 1040
Comment:
  58   Sat Mar 30 16:24:39 2024 hh, mb, ps1st tests1041TJ-Monopix2800 MeVLow Flux LowProtonUnknown30.03.2024 16:20:3430.03.2024 16:27:056HV
automatic log for run 1041
Comment:
  59   Sat Mar 30 16:38:41 2024 hh, mb, ps1st tests1042TJ-Monopix2800 MeVLow Flux LowProtonUnknown30.03.2024 16:32:1230.03.2024 16:41:088HV
automatic log for run 1042
Comment: First good run
  60   Sat Mar 30 16:50:35 2024 hh, mb, ps1st tests1043TJ-Monopix2800 MeVLow Flux LowProtonUnknown30.03.2024 16:48:3930.03.2024 16:53:014HV
automatic log for run 1043
Comment:
  61   Sat Mar 30 17:00:53 2024 hh, mb, ps1st tests1044TJ-Monopix2800 MeVLow Flux LowProtonUnknown30.03.2024 16:57:0830.03.2024 17:03:206HV
automatic log for run 1044
Comment:
  62   Sat Mar 30 17:07:45 2024 hh, mb, ps1st tests1045TJ-Monopix2800 MeVLow Flux LowProtonUnknown30.03.2024 17:07:0130.03.2024 17:10:123HV
automatic log for run 1045
Comment:
  63   Sat Mar 30 17:31:59 2024 hh, mb, psHigh statistics1046TJ-Monopix2800 MeVLow Flux LowProtonUnknown30.03.2024 17:13:0930.03.2024 17:34:2521HV
automatic log for run 1046
Comment:
High statistics run, from now we fix the geometry

Veto: 7us (100, so 7 us is handshake time)
  65   Sat Mar 30 19:24:57 2024 hh, mb, psHigh statistics1048TJ-Monopix2800 MeVLow Flux MediumProtonUnknown30.03.2024 19:02:5230.03.2024 19:27:2424HV
automatic log for run 1048
Comment:
Run with medium settings
  66   Sat Mar 30 19:36:57 2024 hh, mb, psHigh statistics1049TJ-Monopix2800 MeVLow Flux MediumProtonUnknown30.03.2024 19:28:4430.03.2024 19:39:2410HV
automatic log for run 1049
Comment:
Try with increased veto period of 20us (800)
  67   Sat Mar 30 19:44:43 2024 hh, mb, psHigh statistics1050TJ-Monopix2800 MeVLow Flux MediumProtonUnknown30.03.2024 19:40:2130.03.2024 19:47:106HV
automatic log for run 1050
Comment:
Try with increased veto period of 20us (800)
  68   Sat Mar 30 20:13:29 2024 hh, mb, psHigh statistics1051TJ-Monopix2800 MeVLow Flux MediumProtonUnknown30.03.2024 19:48:3630.03.2024 20:15:5527HV
automatic log for run 1051
Comment:
Try with increased veto period of 20us (800)
  69   Sat Mar 30 20:27:35 2024 hh, mb, psHigh statistics1052TJ-Monopix2800 MeVLow Flux MediumProtonUnknown30.03.2024 20:17:1130.03.2024 20:30:0212HV
automatic log for run 1052
Comment:
Back to stock veto period of 7us (100)
  70   Sat Mar 30 20:46:41 2024 hh, mb, psHigh statistics1053TJ-Monopix2800 MeVLow Flux HighProtonUnknown30.03.2024 20:31:1430.03.2024 20:49:0817HV
automatic log for run 1053
Comment:
Back to stock veto period of 7us (100)
Lets try with high
  71   Sat Mar 30 20:51:31 2024 hh, mb, psHigh statistics1054TJ-Monopix2800 MeVLow Flux HighProtonUnknown30.03.2024 20:50:5330.03.2024 20:53:583HV
automatic log for run 1054
Comment:
Litle high settings run
  9   Sat Mar 30 07:59:41 2024 bp, ci, hhRD50-MPW41006RD50-MPW4800 MeVLow Flux Very LowProtonGood30.03.2024 07:46:5030.03.2024 08:02:0815Normal
automatic log for run 1006
Comment:
beautifully correlated Big grin
  12   Sat Mar 30 08:21:04 2024 bp, ci, hhRD50-MPW41007RD50-MPW4800 MeVLow Flux Very LowProtonGood30.03.2024 08:02:4630.03.2024 08:23:3020Normal
automatic log for run 1007
Comment:
waiting for eam
  13   Sat Mar 30 08:34:12 2024 bp, ci, hhRD50-MPW4 RD50-MPW4800 MeVLow Flux Very LowProtonGood   Normal
beam should be back, there was something in the nozzle too
  14   Sat Mar 30 08:38:21 2024 bp, ci, hhRD50-MPW4 RD50-MPW4800 MeVLow Flux Very LowProtonGood   Normal
beam not back, fake news
  21   Sat Mar 30 09:36:22 2024 bp, ci, hhRD50-MPW41011RD50-MPW4800 MeVLow Flux Very LowProtonGood30.03.2024 09:30:1830.03.2024 09:38:488Normal
automatic log for run 1011
Comment:
testing new tablealignment
  22   Sat Mar 30 09:42:55 2024 bp, ci, hhRD50-MPW41012RD50-MPW4800 MeVLow Flux LowProtonGood30.03.2024 09:39:0830.03.2024 09:45:216Normal
automatic log for run 1012
Comment:
changed rate
ELOG V3.1.5-fc6679b