Entry  Sun Jun 9 01:26:56 2024, Felix Ulrich-Pur, TOF CAL HADES LGADs WET Messung Knochen, 24, TOF-Cal GSI, 145.4 MeV, Low Flux High, Proton, Good, 01:02, 01:14, , , ,  
2 cm dense bone (in isocentre)
2.1 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 315 kHz on LGAD

WET measurement
Entry  Sat Dec 14 15:41:43 2024, Felix Ulrich-Pur, plastic mouse radiography, 64, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 97.2MeV/u, Low Flux High, Helium, Good, 00:54, 01:08, 17, , plastic mouse,  
pos x=175, posy=-75

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset
Entry  Sun Jun 9 01:25:26 2024, Felix Ulrich-Pur, TOF CAL HADES LGADs WET Messung Knochen, 23, TOF-Cal GSI, 194.3 MeV, Low Flux High, Proton, Good, 00:30, 01:02, , , ,  
2 cm dense bone (in isocentre)
- Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 1 MHz on LGAD

interlock at 00:31 till 00:50 --> 19min break
Entry  Sat Dec 14 15:41:19 2024, Felix Ulrich-Pur, plastic mouse radiography, 63, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 97.2MeV/u, Low Flux High, Helium, Good, 00:37, 00:54, 17, , plastic mouse,  
pos x=100, posy=-75

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset
Entry  Sat Dec 14 15:40:45 2024, Felix Ulrich-Pur, plastic mouse radiography, 62, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 97.2MeV/u, Low Flux High, Helium, Good, 00:22, 00:37, 15, , plastic mouse,  
pos x=25, posy=-75

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset
Entry  Sun Jun 9 01:22:48 2024, Felix Ulrich-Pur, TOF CAL HADES LGADs WET Messung Knochen, 22, TOF-Cal GSI, 145.4 MeV, Low Flux High, Proton, Good, 00:14, 00:23, , , ,  
1 cm dense bone (in isocentre)
2.8 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 600 kHz on LGAD

WET measurement
Entry  Sat Dec 14 15:40:09 2024, Felix Ulrich-Pur, plastic mouse radiography, 61, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 97.2MeV/u, Low Flux High, Helium, Good, 00:09, 00:22, 13, , plastic mouse,  
pos x=-25, posy=-75

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset
Entry  Sun Jun 9 00:12:41 2024, Felix Ulrich-Pur, TOF CAL HADES LGADs WET Messung Knochen, 21, TOF-Cal GSI, 194.3 MeV, Low Flux High, Proton, Good, 00:00, 00:14, , , ,  
1 cm dense bone (in isocentre)
4.5 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 1.2 MHz on LGAD

WET measurement
Entry  Sat Dec 14 15:39:42 2024, Felix Ulrich-Pur, plastic mouse radiography, 60, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 97.2MeV/u, Low Flux High, Helium, Good, 23:50, 00:08, 18, , plastic mouse,  
pos x=-100, posy=-75

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset
Entry  Sun Jun 9 00:10:38 2024, Felix Ulrich-Pur, TOF CAL HADES LGADs WET Messung Wasser, 20, TOF-Cal GSI, 145.4 MeV, Low Flux High, Proton, Good, 23:31, 00:00, , , ,  
5 cm plastic water (in isocentre)
2 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 330 kHz on LGAD

14 min break with beam off (DAQ failed, had to power cycle TRB3s and all DIRICH boards-->out of synch DIRICH)
Entry  Sat Mar 30 06:34:39 2024, Bernhard Pilsl, And a new testbeam starts :D, , , , , , , , , , , ,  
 
Entry  Sat Mar 30 06:53:31 2024, bp, ci, hh, RD50-MPW4, , RD50-MPW4, 800 MeV, Low Flux Very Low, Proton, Unknown, , , , Normal, ,  mpw4.inidetectors.geo
about to start

geo and eudaq ini attached
Entry  Sat Mar 30 07:59:55 2024, bp, ci, hh, RD50-MPW4, , RD50-MPW4, 800 MeV, Low Flux Very Low, Proton, Crap, , , , Normal, ,  
currently no beam
Entry  Sat Mar 30 08:05:59 2024, Christian Irmler, RD50-MPW4, 999, , , , , , , , , , ,  
Tracker calibration run: mpw4-tj-monopix2_00-000999.xml
Generated global xml file for MPW4 shift: mpw4-tj-monopix2_TLU_00-000999.xml 

Previous local runs and xml files (mpw4-tj-monopix2_00-000212.xml) are unusable, because sensor L5.1.1.0 had a loose cotact and thus low gain.
Entry  Sat Mar 30 08:34:12 2024, bp, ci, hh, RD50-MPW4, , RD50-MPW4, 800 MeV, Low Flux Very Low, Proton, Good, , , , Normal, ,  
beam should be back, there was something in the nozzle too
Entry  Sat Mar 30 08:38:21 2024, bp, ci, hh, RD50-MPW4, , RD50-MPW4, 800 MeV, Low Flux Very Low, Proton, Good, , , , Normal, ,  
beam not back, fake news
Entry  Sat Mar 30 08:56:25 2024, bp, ci, hh, RD50-MPW4, , RD50-MPW4, 800 MeV, Low Flux Very Low, Proton, Crap, , , , Normal, ,  
waiting for beam
Performing MTS restart
Entry  Sat Mar 30 09:15:13 2024, bp, ci, hh, RD50-MPW4, , RD50-MPW4, 800 MeV, Low Flux Very Low, Proton, Crap, , , , Normal, ,  
moved entire setup a bit in order too better focus beam on MPW4 (hopefully)
Entry  Sat Mar 30 09:25:05 2024, bp, ci, hh, RD50-MPW4, , RD50-MPW4, 800 MeV, Low Flux Very Low, Proton, Crap, , , , Normal, ,  
bea is back :D
Entry  Sat Mar 30 09:43:29 2024, bp, ci, hh, RD50-MPW4, , RD50-MPW4, 800 MeV, Low Flux Low, Proton, Good, , , , Normal, ,  
max triggerof tracker set to 100