Home
CMS Production
Clean room
MedAustron
HEPHY
testbeams
old
testbeam-MA2018
testbeam-MA2019
testbeam-MA2020
testbeam-MA2021
testbeam-MA2023
testbeam-MA2024
Testbeams at MedAustron in 2024, Page 10 of 11
Not logged in
Find
|
Login
|
Help
Full
| Summary |
Threaded
-- All entries --
Last day
Last 3 Days
Last week
Last month
Last 3 Months
Last 6 Months
Last Year
-- DUT --
common
DSSD-Tracker
RD50-MPW4
TJ-Monopix2
Wxxx topside
TOF-Cal GSI
RaMon
TOF-Cal GSI \(TRB)+DOGMA setup\(diamond+LGAD)+RaMon
-- Beam Energy --
800 MeV
252.7 MeV
194.3 MeV
175.3 MeV
145.4 MeV
100.4 MeV
83 MeV
62.4 MeV
4.2
115.7MeV
205.2 MeV/u
177.8 MeV/u
147.2 MeV/u
124.4 MeV/u
97.2MeV/u
73.2 MeV/u
63.3 MeV/u
402MeV/u
217 Entries
Goto page
Previous
1
,
2
,
3
...
9
, 10,
11
Next
All
ID
Date
Author
Subject
Run Number
DUT
Beam Energy
Rate Setting
Particle Type
Data
t-Start
t-Stop
Duration_min
Frontend
Phantom
Phantom thickness
Text
74
Sat Jun 8 19:57:39 2024
Felix Ulrich-Pur
TOF CAL HADES LGADs Calibrationcurve
3
TOF-Cal GSI
194.3 MeV
Low Flux Medium
Proton
Good
16:51
17:28
600 khz on Ramon (after 5 Layers of Silicon
and close to second iso centre) and 235kHz
on LGAD
75
Sat Jun 8 20:05:27 2024
Felix Ulrich-Pur
TOF CAL HADES LGADs Calibrationcurve
4
TOF-Cal GSI
175.3 MeV
Low Flux Medium
Proton
Good
17:31
17:54
500 khz on Ramon (after 5 Layers of Silicon
and close to second iso centre) and 170kHz
on LGAD
76
Sat Jun 8 20:07:44 2024
Felix Ulrich-Pur
TOF CAL HADES LGADs Calibrationcurve
5
TOF-Cal GSI
145.4 MeV
Low Flux Medium
Proton
Good
17:55
18:24
400 khz on Ramon (after 5 Layers of Silicon
and close to second iso centre) and 120kHz
on LGAD
77
Sat Jun 8 20:08:55 2024
Felix Ulrich-Pur
TOF CAL HADES LGADs Calibrationcurve
6
TOF-Cal GSI
115.7MeV
Low Flux Medium
Proton
Good
18:24
19:00
400 khz on Ramon (after 5 Layers of Silicon
and close to second iso centre) and 65kHz
on LGAD
78
Sat Jun 8 20:09:25 2024
Felix Ulrich-Pur
TOF CAL HADES LGADs Calibrationcurve
7
TOF-Cal GSI
100.4 MeV
Low Flux Medium
Proton
Good
19:00
19:42
300 khz on Ramon (after 5 Layers of Silicon
and close to second iso centre) and 65kHz
on LGAD
79
Sat Jun 8 20:11:00 2024
Felix Ulrich-Pur
TOF CAL HADES LGADs Calibrationcurve
8
TOF-Cal GSI
83 MeV
Low Flux Medium
Proton
Good
19:42
20:51
300 khz on Ramon (after 5 Layers of Silicon
and close to second iso centre) and 35kHz
on LGAD
80
Sat Jun 8 21:41:04 2024
Felix Ulrich-Pur
TOF CAL HADES LGADs Calibrationcurve
9
TOF-Cal GSI
62.4 MeV
Low Flux High
Proton
Good
20:55
21:21
changed back to high due to beamsize vs
LGAD size factor
650 khz on Ramon (after 5 Layers of
81
Sat Jun 8 21:42:13 2024
Felix Ulrich-Pur
TOF CAL HADES LGADs WET Messung Wasser
10
TOF-Cal GSI
194.3 MeV
Low Flux High
Proton
Good
21:27
21:39
1cm plastic water (in isocentre)
6 Mhz on Ramon (after 5 Layers of
Silicon and close to second iso centre) and
82
Sat Jun 8 21:43:26 2024
Felix Ulrich-Pur
TOF CAL HADES LGADs WET Messung Wasser
11
TOF-Cal GSI
145.4 MeV
Low Flux High
Proton
Good
21:39
21:48
1cm plastic water (in isocentre)
4 Mhz on Ramon (after 5 Layers of
Silicon and close to second iso centre) and
83
Sat Jun 8 21:54:59 2024
Felix Ulrich-Pur
TOF CAL HADES LGADs WET Messung Wasser
12
TOF-Cal GSI
194.3 MeV
Low Flux High
Proton
Good
21:53
22:05
2cm plastic water (in isocentre)
5 Mhz on Ramon (after 5 Layers of
Silicon and close to second iso centre) and
84
Sat Jun 8 22:12:06 2024
Felix Ulrich-Pur
TOF CAL HADES LGADs WET Messung Wasser
13
TOF-Cal GSI
145.4 MeV
Low Flux High
Proton
Good
22:05
22:34
2cm plastic water (in isocentre)
3.2 Mhz on Ramon (after 5 Layers of
Silicon and close to second iso centre) and
85
Sat Jun 8 22:38:41 2024
Felix Ulrich-Pur
TOF CAL HADES LGADs WET Messung Wasser
14
TOF-Cal GSI
194.3 MeV
Low Flux High
Proton
Good
22:19
22.34
3 cm plastic water (in isocentre)
4.3 Mhz on Ramon (after 5 Layers of
Silicon and close to second iso centre) and
86
Sun Jun 9 00:04:23 2024
Felix Ulrich-Pur
TOF CAL HADES LGADs WET Messung Wasser
15
TOF-Cal GSI
194.3 MeV
Low Flux High
Proton
Good
22:34
22:50
3 cm plastic water (in isocentre)
2.6 Mhz on Ramon (after 5 Layers of
Silicon and close to second iso centre) and
87
Sun Jun 9 00:05:11 2024
Felix Ulrich-Pur
TOF CAL HADES LGADs WET Messung Wasser (wrong energy)
16
TOF-Cal GSI
194.3 MeV
Low Flux High
Proton
Crap
22:50
22:52
wrong energy don't use
88
Sun Jun 9 00:06:01 2024
Felix Ulrich-Pur
TOF CAL HADES LGADs WET Messung Wasser
17
TOF-Cal GSI
194.3 MeV
Low Flux High
Proton
Good
22:53
23:04
4 cm plastic water (in isocentre)
3.8 Mhz on Ramon (after 5 Layers of
Silicon and close to second iso centre) and
89
Sun Jun 9 00:07:17 2024
Felix Ulrich-Pur
TOF CAL HADES LGADs WET Messung Wasser
18
TOF-Cal GSI
145.4 MeV
Low Flux High
Proton
Good
23:04
23:20
4 cm plastic water (in isocentre)
2 Mhz on Ramon (after 5 Layers of
Silicon and close to second iso centre) and
90
Sun Jun 9 00:08:07 2024
Felix Ulrich-Pur
TOF CAL HADES LGADs WET Messung Wasser
19
TOF-Cal GSI
194.3 MeV
Low Flux High
Proton
Good
23:20
23:30
5 cm plastic water (in isocentre)
3.7 Mhz on Ramon (after 5 Layers of
Silicon and close to second iso centre) and
91
Sun Jun 9 00:10:38 2024
Felix Ulrich-Pur
TOF CAL HADES LGADs WET Messung Wasser
20
TOF-Cal GSI
145.4 MeV
Low Flux High
Proton
Good
23:31
00:00
5 cm plastic water (in isocentre)
2 Mhz on Ramon (after 5 Layers of
Silicon and close to second iso centre) and
92
Sun Jun 9 00:12:41 2024
Felix Ulrich-Pur
TOF CAL HADES LGADs WET Messung Knochen
21
TOF-Cal GSI
194.3 MeV
Low Flux High
Proton
Good
00:00
00:14
1 cm dense bone (in isocentre)
4.5 Mhz on Ramon (after 5 Layers of
Silicon and close to second iso centre) and
93
Sun Jun 9 01:22:48 2024
Felix Ulrich-Pur
TOF CAL HADES LGADs WET Messung Knochen
22
TOF-Cal GSI
145.4 MeV
Low Flux High
Proton
Good
00:14
00:23
1 cm dense bone (in isocentre)
2.8 Mhz on Ramon (after 5 Layers of
Silicon and close to second iso centre) and
Goto page