ID Date Author Subject Run Number DUT Beam Energy Rate Setting Particle Type Data t-Start t-Stopdown Duration_min Frontend Phantom Phantom thickness
  95   Sun Jun 9 01:26:56 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Knochen24TOF-Cal GSI145.4 MeVLow Flux HighProtonGood01:0201:14    

2 cm dense bone (in isocentre)
2.1 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 315 kHz on LGAD

WET measurement

  202   Sat Dec 14 15:41:43 2024 Felix Ulrich-Purplastic mouse radiography64TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood00:5401:0817 plastic mouse 

pos x=175, posy=-75

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  94   Sun Jun 9 01:25:26 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Knochen23TOF-Cal GSI194.3 MeVLow Flux HighProtonGood00:3001:02    

2 cm dense bone (in isocentre)
- Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 1 MHz on LGAD

interlock at 00:31 till 00:50 --> 19min break

WET measurement

  201   Sat Dec 14 15:41:19 2024 Felix Ulrich-Purplastic mouse radiography63TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood00:3700:5417 plastic mouse 

pos x=100, posy=-75

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  200   Sat Dec 14 15:40:45 2024 Felix Ulrich-Purplastic mouse radiography62TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood00:2200:3715 plastic mouse 

pos x=25, posy=-75

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  93   Sun Jun 9 01:22:48 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Knochen22TOF-Cal GSI145.4 MeVLow Flux HighProtonGood00:1400:23    

1 cm dense bone (in isocentre)
2.8 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 600 kHz on LGAD

WET measurement

  199   Sat Dec 14 15:40:09 2024 Felix Ulrich-Purplastic mouse radiography61TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood00:0900:2213 plastic mouse 

pos x=-25, posy=-75

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  92   Sun Jun 9 00:12:41 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Knochen21TOF-Cal GSI194.3 MeVLow Flux HighProtonGood00:0000:14    

1 cm dense bone (in isocentre)
4.5 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 1.2 MHz on LGAD

WET measurement

  198   Sat Dec 14 15:39:42 2024 Felix Ulrich-Purplastic mouse radiography60TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood23:5000:0818 plastic mouse 

pos x=-100, posy=-75

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

  91   Sun Jun 9 00:10:38 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Wasser20TOF-Cal GSI145.4 MeVLow Flux HighProtonGood23:3100:00    

5 cm plastic water (in isocentre)
2 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 330 kHz on LGAD

14 min break with beam off (DAQ failed, had to power cycle TRB3s and all DIRICH boards-->out of synch DIRICH)

WET measurement

  1   Sat Mar 30 06:34:39 2024 Bernhard PilslAnd a new testbeam starts :D            
  2   Sat Mar 30 06:53:31 2024 bp, ci, hhRD50-MPW4 RD50-MPW4800 MeVLow Flux Very LowProtonUnknown   Normal  
about to start

geo and eudaq ini attached
  10   Sat Mar 30 07:59:55 2024 bp, ci, hhRD50-MPW4 RD50-MPW4800 MeVLow Flux Very LowProtonCrap   Normal  
currently no beam
  11   Sat Mar 30 08:05:59 2024 Christian IrmlerRD50-MPW4999           

Tracker calibration run: mpw4-tj-monopix2_00-000999.xml
Generated global xml file for MPW4 shift: mpw4-tj-monopix2_TLU_00-000999.xml 

Previous local runs and xml files (mpw4-tj-monopix2_00-000212.xml) are unusable, because sensor L5.1.1.0 had a loose cotact and thus low gain.
Fixed by disconnecting and reconnecting.

  13   Sat Mar 30 08:34:12 2024 bp, ci, hhRD50-MPW4 RD50-MPW4800 MeVLow Flux Very LowProtonGood   Normal  
beam should be back, there was something in the nozzle too
  14   Sat Mar 30 08:38:21 2024 bp, ci, hhRD50-MPW4 RD50-MPW4800 MeVLow Flux Very LowProtonGood   Normal  
beam not back, fake news
  16   Sat Mar 30 08:56:25 2024 bp, ci, hhRD50-MPW4 RD50-MPW4800 MeVLow Flux Very LowProtonCrap   Normal  
waiting for beam
Performing MTS restart
  18   Sat Mar 30 09:15:13 2024 bp, ci, hhRD50-MPW4 RD50-MPW4800 MeVLow Flux Very LowProtonCrap   Normal  
moved entire setup a bit in order too better focus beam on MPW4 (hopefully)
  19   Sat Mar 30 09:25:05 2024 bp, ci, hhRD50-MPW4 RD50-MPW4800 MeVLow Flux Very LowProtonCrap   Normal  
bea is back Big grin
  23   Sat Mar 30 09:43:29 2024 bp, ci, hhRD50-MPW4 RD50-MPW4800 MeVLow Flux LowProtonGood   Normal  
max triggerof tracker set to 100