Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024
  Testbeams at MedAustron in 2024, Page 1 of 4  Not logged in ELOG logo
Entry  Sat Mar 30 20:51:31 2024, hh, mb, ps, High statistics, 1054, TJ-Monopix2, 800 MeV, Low Flux High, Proton, Unknown, 30.03.2024 20:50:53, 30.03.2024 20:53:58, 3, HV tjmonopix2.conf
automatic log for run 1054
Comment:
Litle high  settings run
Entry  Sat Mar 30 20:46:41 2024, hh, mb, ps, High statistics, 1053, TJ-Monopix2, 800 MeV, Low Flux High, Proton, Unknown, 30.03.2024 20:31:14, 30.03.2024 20:49:08, 17, HV tjmonopix2.conf
automatic log for run 1053
Comment:
Back to stock veto period of 7us (100)
Entry  Sat Mar 30 20:27:35 2024, hh, mb, ps, High statistics, 1052, TJ-Monopix2, 800 MeV, Low Flux Medium, Proton, Unknown, 30.03.2024 20:17:11, 30.03.2024 20:30:02, 12, HV tjmonopix2.conf
automatic log for run 1052
Comment:
Back to stock veto period of 7us (100)
Entry  Sat Mar 30 20:13:29 2024, hh, mb, ps, High statistics, 1051, TJ-Monopix2, 800 MeV, Low Flux Medium, Proton, Unknown, 30.03.2024 19:48:36, 30.03.2024 20:15:55, 27, HV tjmonopix2.conf
automatic log for run 1051
Comment:
Try with increased veto period of 20us (800)
Entry  Sat Mar 30 19:44:43 2024, hh, mb, ps, High statistics, 1050, TJ-Monopix2, 800 MeV, Low Flux Medium, Proton, Unknown, 30.03.2024 19:40:21, 30.03.2024 19:47:10, 6, HV tjmonopix2.conf
automatic log for run 1050
Comment:
Try with increased veto period of 20us (800)
Entry  Sat Mar 30 19:36:57 2024, hh, mb, ps, High statistics, 1049, TJ-Monopix2, 800 MeV, Low Flux Medium, Proton, Unknown, 30.03.2024 19:28:44, 30.03.2024 19:39:24, 10, HV tjmonopix2.conf
automatic log for run 1049
Comment:
Try with increased veto period of 20us (800)
Entry  Sat Mar 30 19:24:57 2024, hh, mb, ps, High statistics, 1048, TJ-Monopix2, 800 MeV, Low Flux Medium, Proton, Unknown, 30.03.2024 19:02:52, 30.03.2024 19:27:24, 24, HV tjmonopix2.conf
automatic log for run 1048
Comment:
Run with medium settings
Entry  Sat Mar 30 18:59:16 2024, hh, mb, ps, 1st tests, 1047, TJ-Monopix2, 800 MeV, Low Flux Low, Proton, Crap, 30.03.2024 19:00:11, 30.03.2024 19:01:43, 1, HV tjmonopix2.conf
automatic log for run 1047
Comment:
Test if we get beam, MAUS has problems
Entry  Sat Mar 30 17:31:59 2024, hh, mb, ps, High statistics, 1046, TJ-Monopix2, 800 MeV, Low Flux Low, Proton, Unknown, 30.03.2024 17:13:09, 30.03.2024 17:34:25, 21, HV tjmonopix2.conftestbench_AB.yamltestbench_CD.yaml
automatic log for run 1046
Comment:
High statistics run, from now we fix the geometry
Entry  Sat Mar 30 17:07:45 2024, hh, mb, ps, 1st tests, 1045, TJ-Monopix2, 800 MeV, Low Flux Low, Proton, Unknown, 30.03.2024 17:07:01, 30.03.2024 17:10:12, 3, HV tjmonopix2.conf
automatic log for run 1045
Comment:
Entry  Sat Mar 30 17:00:53 2024, hh, mb, ps, 1st tests, 1044, TJ-Monopix2, 800 MeV, Low Flux Low, Proton, Unknown, 30.03.2024 16:57:08, 30.03.2024 17:03:20, 6, HV tjmonopix2.conf
automatic log for run 1044
Comment:
Entry  Sat Mar 30 16:50:35 2024, hh, mb, ps, 1st tests, 1043, TJ-Monopix2, 800 MeV, Low Flux Low, Proton, Unknown, 30.03.2024 16:48:39, 30.03.2024 16:53:01, 4, HV tjmonopix2.conf
automatic log for run 1043
Comment:
Entry  Sat Mar 30 16:38:41 2024, hh, mb, ps, 1st tests, 1042, TJ-Monopix2, 800 MeV, Low Flux Low, Proton, Unknown, 30.03.2024 16:32:12, 30.03.2024 16:41:08, 8, HV tjmonopix2.conf
automatic log for run 1042
Comment: First good run
Entry  Sat Mar 30 16:24:39 2024, hh, mb, ps, 1st tests, 1041, TJ-Monopix2, 800 MeV, Low Flux Low, Proton, Unknown, 30.03.2024 16:20:34, 30.03.2024 16:27:05, 6, HV tjmonopix2.conf
automatic log for run 1041
Comment:
Entry  Sat Mar 30 16:15:20 2024, hh, mb, ps, 1st tests, 1040, TJ-Monopix2, 800 MeV, Low Flux Low, Proton, Unknown, 30.03.2024 16:15:22, 30.03.2024 16:17:46, 2, HV tjmonopix2.conf
automatic log for run 1040
Comment:
Entry  Sat Mar 30 16:09:54 2024, hh, mb, ps, 1st tests, 1039, TJ-Monopix2, 800 MeV, Low Flux Low, Proton, Unknown, 30.03.2024 16:11:32, 30.03.2024 16:12:21, 0, HV tjmonopix2.conf
automatic log for run 1039
Comment:
Entry  Sat Mar 30 16:03:35 2024, hh, mb, ps, 1st tests, 1038, TJ-Monopix2, 800 MeV, Low Flux Low, Proton, Unknown, 30.03.2024 16:03:18, 30.03.2024 16:06:01, 2, HV tjmonopix2.conf
automatic log for run 1038
Comment:
Entry  Sat Mar 30 15:55:32 2024, hh, mb, ps, 1st tests, 1037, TJ-Monopix2, 800 MeV, Low Flux Low, Proton, Unknown, 30.03.2024 15:54:44, 30.03.2024 15:57:59, 3, HV tjmonopix2.conf
automatic log for run 1037
Comment:
Entry  Sat Mar 30 15:51:21 2024, hh, mb, ps, 1st tests, 1036, TJ-Monopix2, 800 MeV, Low Flux Low, Proton, Unknown, 30.03.2024 15:43:53, 30.03.2024 15:53:47, 9, HV tjmonopix2.conf
automatic log for run 1036
Comment:
Entry  Sat Mar 30 15:39:06 2024, hh, mb, ps, 1st tests, 1035, TJ-Monopix2, 800 MeV, Low Flux Low, Proton, Unknown, 30.03.2024 15:35:06, 30.03.2024 15:41:33, 6, HV tjmonopix2.conf
automatic log for run 1035

All four chips enabled now
ELOG V3.1.5-fc6679b