  Testbeams at MedAustron in 2024, Page 1 of 11  Not logged in ELOG logo
ID Date Author Subject Run Number DUT Beam Energydown Rate Setting Particle Type Data t-Start t-Stop Duration_min Frontend Phantom Phantom thickness Text Attachments
  144   Sat Dec 14 12:54:04 2024 Felix Ulrich-PurShift 23.11.24 low flux He test with RaMon5RaMon97.2MeV/uLow Flux MediumHeliumGood06:3306:331   Mean rate per spill~ 1-5E5 p/s (online
estimation without proper analysis)
  
  151   Sat Dec 14 12:59:33 2024 Felix Ulrich-PurShift 23.11.24 low flux He test with RaMon12RaMon97.2MeV/uLow Flux HighHeliumGood06:4306:441   Mean rate per spill~ 6Ee6 p/s (online estimation
without proper analysis)
  
  161   Sat Dec 14 13:34:18 2024 Felix Ulrich-PurEnergy vs TOF calibration21TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood10:5811:2325   TRB Setup: 260V bias and 250mA pre-amps,
threshold 1000

3MHz with Ramon and only 300kHz
  
  188   Sat Dec 14 15:28:46 2024 Felix Ulrich-Purthreshold and preamp tests49TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood20:0420:095   TRB Setup: 260V bias and 250mA pre-amps,
threshold 10000 (was too high)

Diamond: 900mA, threshold 1000
  
  189   Sat Dec 14 15:30:23 2024 Felix Ulrich-Purthreshold and preamp tests50TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood20:1920:3516   TRB Setup: 260V bias and 250mA pre-amps,
threshold 5000 (looks good, clustersize max
at ~3)
  
  190   Sat Dec 14 15:31:32 2024 Felix Ulrich-Purplastic mouse radiography51TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood21:1421:3016 plastic mouse before run, mouse was aligned with lasers
and shift of beam w.r.t. sensor center was
taken into account
  
  191   Sat Dec 14 15:33:35 2024 Felix Ulrich-Purplastic mouse radiography53TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood21:3321:5724 plastic mouse run 52 was crap

pos x=175, posy=0

TRB Setup: 260V bias and 250mA
  
  192   Sat Dec 14 15:34:50 2024 Felix Ulrich-Purplastic mouse radiography54TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood21:5822:1022 plastic mouse pos x=100, posy=0

TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000
  
  193   Sat Dec 14 15:35:56 2024 Felix Ulrich-Purplastic mouse radiography55TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood22:1222:4533 plastic mouse pos x=25, posy=0

TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000
  
  194   Sat Dec 14 15:36:37 2024 Felix Ulrich-Purplastic mouse radiography56TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood22:4623:0014 plastic mouse pos x=-25, posy=0

TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000
  
  195   Sat Dec 14 15:37:26 2024 Felix Ulrich-Purplastic mouse radiography57TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood23:0223:1614 plastic mouse pos x=-100, posy=0

TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000
  
  196   Sat Dec 14 15:37:48 2024 Felix Ulrich-Purplastic mouse radiography58TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood23:1723:3013 plastic mouse pos x=-175, posy=0

TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000
  
  197   Sat Dec 14 15:39:11 2024 Felix Ulrich-Purplastic mouse radiography59TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood23:3323:4613 plastic mouse pos x=-175, posy=-75

TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000
  
  198   Sat Dec 14 15:39:42 2024 Felix Ulrich-Purplastic mouse radiography60TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood23:5000:0818 plastic mouse pos x=-100, posy=-75

TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000
  
  199   Sat Dec 14 15:40:09 2024 Felix Ulrich-Purplastic mouse radiography61TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood00:0900:2213 plastic mouse pos x=-25, posy=-75

TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000
  
  200   Sat Dec 14 15:40:45 2024 Felix Ulrich-Purplastic mouse radiography62TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood00:2200:3715 plastic mouse pos x=25, posy=-75

TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000
  
  201   Sat Dec 14 15:41:19 2024 Felix Ulrich-Purplastic mouse radiography63TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood00:3700:5417 plastic mouse pos x=100, posy=-75

TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000
  
  202   Sat Dec 14 15:41:43 2024 Felix Ulrich-Purplastic mouse radiography64TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood00:5401:0817 plastic mouse pos x=175, posy=-75

TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000
  
  203   Sat Dec 14 15:42:01 2024 Felix Ulrich-Purplastic mouse radiography65TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood01:0801:2012 plastic mouse pos x=250, posy=-75

TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000
  
  204   Sat Dec 14 15:42:32 2024 Felix Ulrich-Purplastic mouse radiography66TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood01:2101:3413 plastic mouse pos x=250, posy=75

TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000
  