  87   Sat Feb 27 18:42:13 2021 Felix Ulrich-PurWaveforms SiC+Si13SiC+Si+RaMon252.7III(EFE+SID2)  Good        

Start 10:38
no signal in SiC

channel 1 : Si upstream
channel 2: SiC downstream

400 V Bias

Referenz: 2.100 V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.477V channel 1, 0-Level: 2.315V channel 1

position:

x = 8
y = 68

  88   Sat Feb 27 18:43:12 2021 Felix Ulrich-PurWaveforms SiC+Si14SiC+Si+RaMon145.4III(EFE+SID2)  Good        

Start 10:47

channel 1 : Si upstream
channel 2: SiC downstream

400 V Bias

Referenz: 2.100 V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.477V channel 1, 0-Level: 2.315V channel 1

position:

x = 8
y = 68

  89   Sat Feb 27 18:43:35 2021 Felix Ulrich-PurWaveforms SiC+Si15SiC+Si+RaMon100.4III(EFE+SID2)  Good        

Start 11:09

channel 1 : Si upstream
channel 2: SiC downstream

400 V Bias

Referenz: 2.100 V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.477V channel 1, 0-Level: 2.315V channel 1

position:

x = 8
y = 68

  90   Sat Feb 27 18:44:06 2021 Felix Ulrich-PurWaveforms SiC+Si16SiC+Si+RaMon100.4I(EFE+SID0)  Good        

Start 11:36

schöne Signale

channel 1 : Si upstream
channel 2: SiC downstream

400 V Bias

Referenz: 2.100 V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.477V channel 1, 0-Level: 2.315V channel 1

position:

x = 8
y = 68

  91   Sat Feb 27 18:44:23 2021 Felix Ulrich-PurWaveforms SiC+Si17SiC+Si+RaMon800VII  Good        

Start 11:55
Stopped at 12:05-->acc failure

channel 1 : Si upstream
channel 2: SiC downstream

400 V Bias

Referenz: 2.100 V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.477V channel 1, 0-Level: 2.315V channel 1

position:

x = 8
y = 68

  92   Sat Feb 27 18:49:06 2021 Felix Ulrich-PurWaveforms SiC+Si18SiC+Si+RaMon800VII  Good        

Start 12:39

Neustart der vorherigen Messung

channel 1 : Si upstream
channel 2: SiC downstream

400 V Bias

Referenz: 2.100 V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.477V channel 1, 0-Level: 2.315V channel 1

position:

x = 8
y = 68

  93   Sat Feb 27 18:50:16 2021 Felix Ulrich-PurWaveforms SiC+Si19SiC+Si+RaMon252.7nominal  Good  100     

Start 13:40

Degrader 100 
Messung aufgenommen, keine Screenshots

channel 1 : Si upstream
channel 2: SiC downstream

400 V Bias

Referenz: 2.100 V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.477V channel 1, 0-Level: 2.315V channel 1

position:

x = 8
y = 68

  94   Sat Feb 27 18:52:12 2021 Felix Ulrich-PurWaveforms SiC+Si20SiC+Si+RaMon252.7nominalProton Good  10     

Start 13:42

Degrader 10


channel 1 : Si upstream
channel 2: SiC downstream

400 V Bias

Referenz: 2.100 V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.477V channel 1, 0-Level: 2.315V channel 1

position:

x = 8
y = 68

  95   Sat Feb 27 18:56:11 2021 Felix Ulrich-PurWaveforms SiC+Si21SiC+Si+RaMon252.7nominalProton Good  50     

Start 13:56

Degrader 50


channel 1 : Si upstream
channel 2: SiC downstream

400 V Bias

Referenz: 2.100 V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.477V channel 1, 0-Level: 2.315V channel 1

position:

x = 8
y = 68

 

  96   Sat Feb 27 18:56:58 2021 Felix Ulrich-PurWaveforms SiC+Si22SiC+Si+RaMon252.7nominalProton Good  100     

Start 14:08

Degrader 100


channel 1 : Si upstream
channel 2: SiC downstream

400 V Bias

Referenz: 2.100 V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.477V channel 1, 0-Level: 2.315V channel 1

position:

x = 8
y = 68

  97   Sat Feb 27 19:01:26 2021 Felix Ulrich-PurWaveforms SiC+Si23SiC+Si+RaMon400.8nominalCarbon Good  10     

Start 14:18 

14:30 enter room request: abbau and shielding was activated, called RP, removed SiC+Si Setup+Al shielding of DSSDs

Degrader 10, Carbon
Messung bis 14:24

danach neue Aufzeichnung (Hintergrundstrahlung) Start ca 14:25


channel 1 : Si upstream
channel 2: SiC downstream

400 V Bias

Referenz: 2.100 V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.477V channel 1, 0-Level: 2.315V channel 1

position:

x = 8
y = 68