Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024
  MedAustron 2021, Page 6 of 18  Not logged in ELOG logo
IDdown Date Author Subject Run Number DUT Beam Energy Rate Setting Particle Type Events Data Beam Betatron Beam Chopper Beam Degrader Beam EFE Beam Orb Beam QuadScan PhantomType PhantomAngle
  251   Thu Oct 7 10:58:19 2021 Philipp GagglPad Sensoren16SiC+Si62.4II(BETA+EFE)Proton Unknown        

beamtime on 18.09.2021
CH1: SiC
CH3: Si
Bias_Si: -100 V
Bias_SiC: 1000 V
Trigger SiC

  250   Thu Oct 7 10:57:31 2021 Philipp GagglPad Sensoren15SiC+Si62.4II(BETA+EFE)Proton Unknown        

beamtime on 18.09.2021
CH1: SiC
CH3: Si
Bias_Si: -100 V
Bias_SiC: 800 V
Trigger SiC

  249   Thu Oct 7 10:56:59 2021 Philipp GagglPad Sensoren14SiC+Si62.4II(BETA+EFE)Proton Unknown        

beamtime on 18.09.2021
CH1: SiC
CH3: Si
Bias_Si: -100 V
Bias_SiC: 400 V
Repeat of run 13

  248   Thu Oct 7 10:54:33 2021 Philipp GagglPad Sensoren13SiC+Si62.4II(BETA+EFE)Proton Unknown        

beamtime on 18.09.2021
CH1: SiC
CH3: Si
Bias_Si: -100 V
Bias_SiC: 400 V

  247   Thu Oct 7 10:51:38 2021 Philipp GagglPad Sensoren12SiC+Si62.4III(EFE+SID2)Proton Good        

beamtime on 18.09.2021
CH1: SiC
CH3: Si
Bias_Si: -100 V
Bias_SiC: 400 V
Cividec for SiC

  246   Sat Sep 18 07:22:07 2021 Manuel ChristanellPad Sensoren11SiC+Si62.4III(EFE+SID2)Proton          

01. SiC; 2. Si

Small SiC Signal;
Cividec for SiC

  245   Sat Sep 18 06:20:51 2021 Manuel ChristanellPad Sensoren10 62.4III(EFE+SID2)Proton          

01. SiC; 2. Si

Bias 1: 400V; Bias 2: -100 V; SiC with Cividec

  244   Sun Jun 20 20:05:38 2021 Felix Ulrich-PurHADES testrun with increased rate 800MeV17HADES-LGADs800nominalProton Good  10   none0

TB 20.6.21

Start 20:10
Mean rate O(200MHz)
 

  243   Sun Jun 20 20:02:03 2021 Felix Ulrich-PurHADES sandwich TOF15HADES-LGADs+PMMAslabs100.4I(EFE+SID0)Proton Good      PMMA0

TB 20.6.21

Start 18:45
2cm Phantom thickness
Mean rate O(MHz)
for live TOF estimation: TDC3,channel 9 - TDC2,channel9

last sensor did not work

  242   Sun Jun 20 20:00:05 2021 Felix Ulrich-PurHADES testrun 800MeV16HADES-LGADs800VIIProton Good      none0

TB 20.6.21

Start 19:19
Mean rate O(MHz)
 

  241   Sun Jun 20 19:59:31 2021 Felix Ulrich-PurHADES sandwich TOF14HADES-LGADs+PMMAslabs100.4I(EFE+SID0)Proton Good      PMMA0

TB 20.6.21

Start 18:03
1cm Phantom thickness
Mean rate O(MHz)
for live TOF estimation: TDC3,channel 9 - TDC2,channel9

last sensor stopped working
 

  240   Sun Jun 20 19:58:31 2021 Felix Ulrich-PurHADES sandwich TOF13HADES-LGADs+PMMAslabs100.4I(EFE+SID0)Proton Good      PMMA0

TB 20.6.21

Start 17:27
3cm Phantom thickness
Mean rate O(MHz)
for live TOF estimation: TDC3,channel 9 - TDC2,channel9
 

  239   Sun Jun 20 19:55:47 2021 Felix Ulrich-PurHADES sandwich TOF reference run12HADES-LGADs100.4I(EFE+SID0)Proton Good      none0

TB 20.6.21

Start 16:46
0cm Phantom thickness
Mean rate O(MHz)
reference run without phantom
for live TOF estimation: TDC3,channel 9 - TDC2,channel9
 

  238   Sun Jun 20 19:54:37 2021 Felix Ulrich-PurHADES sandwich TOF11HADES-LGADs+PMMAslabs100.4I(EFE+SID0)Proton Good      PMMA0

TB 20.6.21

Start 15:55
5cm Phantom thickness
Mean rate O(MHz)
gain in last 2 layers was adapted
RamonRun 11 was not stopped (beam was still on from previous run)
for live TOF estimation: TDC3,channel 9 - TDC2,channel9
 

  237   Sun Jun 20 19:50:11 2021 Felix Ulrich-PurHADES sandwich TOF11HADES-LGADs+PMMAslabs100.4I(EFE+SID0)Proton Good      PMMA0

TB 20.6.21

Start 15:00 (late handover and copying of data)
5cm Phantom thickness
Mean rate O(MHz)

signal in last 2 LGADs too high (only 52MeV residual energy after 5cm)
 

  236   Sun Jun 20 19:40:12 2021 Felix Ulrich-PurHADES increased rate 10HADES-LGADs800nominalProton Good  10   none0

TB 19.6.21

Start 21:50

Nominal flux degrader 10: mean rate O(200MHz)
 

  235   Sun Jun 20 19:38:28 2021 Felix Ulrich-PurHADES increased rate run (wrong setting9HADES-LGADs800VIIProton Good  20   none0

TB 19.6.21

Start 19:43
rate setting was not set correctly deg20 in combination with setting VII instead of nominal flux deg10
 

  234   Sun Jun 20 19:37:58 2021 Felix Ulrich-PurHADES energy run8HADES-LGADs62.4I(EFE+SID0)Proton Good      none0

TB 19.6.21

Start 19:16
Mean rate O(MHz)
 

  233   Sun Jun 20 19:37:37 2021 Felix Ulrich-PurHADES energy run7HADES-LGADs83I(EFE+SID0)Proton Good      none0

TB 19.6.21

Start 18:48
Mean rate O(MHz)
 

  232   Sun Jun 20 19:37:09 2021 Felix Ulrich-PurHADES energy run6HADES-LGADs145.4I(EFE+SID0)Proton Good      none0

TB 19.6.21

Start 18:15
Mean rate O(MHz)
 

ELOG V3.1.5-fc6679b