Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024
  MedAustron 2021, Page 5 of 18  Not logged in ELOG logo
Entry  Sat Feb 27 19:01:26 2021, Felix Ulrich-Pur, Waveforms SiC+Si, 23, SiC+Si+RaMon, 400.8, nominal, Carbon, , Good, , , 10, , , , ,  

Start 14:18 

14:30 enter room request: abbau and shielding was activated, called RP, removed SiC+Si Setup+Al shielding of DSSDs

Degrader 10, Carbon
Messung bis 14:24

danach neue Aufzeichnung (Hintergrundstrahlung) Start ca 14:25


channel 1 : Si upstream
channel 2: SiC downstream

400 V Bias

Referenz: 2.100 V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.477V channel 1, 0-Level: 2.315V channel 1

position:

x = 8
y = 68

Entry  Tue Mar 16 15:10:11 2021, Patrick Sieberer, Pad Sensoren, 24, , 252.7, nominal, Proton, , Good, , , 10, , , , none,  

Start: 13:57
Range Shifter Out, Filter 1 IN, Filter 2 IN

Entry  Sun Jun 20 19:40:12 2021, Felix Ulrich-Pur, HADES increased rate , 10, HADES-LGADs, 800, nominal, Proton, , Good, , , 10, , , , none, 0 

TB 19.6.21

Start 21:50

Nominal flux degrader 10: mean rate O(200MHz)
 

Entry  Sun Jun 20 20:05:38 2021, Felix Ulrich-Pur, HADES testrun with increased rate 800MeV, 17, HADES-LGADs, 800, nominal, Proton, , Good, , , 10, , , , none, 0 

TB 20.6.21

Start 20:10
Mean rate O(200MHz)
 

Entry  Thu Oct 7 11:03:37 2021, Philipp Gaggl, Pad Sensoren, 27, SiC+Si, 120, , Carbon, , Unknown, , , 10, , , , ,  

beamtime on 18.09.2021
CH1: SiC
CH3: Si
Bias_Si: -100 V
Bias_SiC: 1100 V

Entry  Thu Oct 7 11:07:08 2021, Philipp Gaggl, Pad Sensoren, 28, SiC+Si, 402.8, , Carbon, , Unknown, , , 10, , , , ,  

beamtime on 18.09.2021
CH1: SiC
CH3: Si
Bias_Si: -100 V
Bias_SiC: 1100 V

Entry  Thu Oct 7 11:08:16 2021, Philipp Gaggl, Pad Sensoren, 29, SiC+Si, 213.4, , Carbon, , Unknown, , , 10, , , , ,  

beamtime on 18.09.2021
CH1: SiC
CH3: Si
Bias_Si: -100 V
Bias_SiC: 1100 V

Entry  Thu Oct 7 11:08:51 2021, Philipp Gaggl, Pad Sensoren, 30, SiC+Si, 306.2, , Carbon, , Unknown, , , 10, , , , ,  

beamtime on 18.09.2021
CH1: SiC
CH3: Si
Bias_Si: -100 V
Bias_SiC: 1100 V

Entry  Thu Oct 7 11:10:54 2021, Philipp Gaggl, Pad Sensoren, 31, SiC+Si, 120, , Carbon, , Unknown, , , 10, , , , ,  

beamtime on 18.09.2021
CH1: SiC
CH3: Si
Bias_Si: -100 V
Bias_SiC: 800 V

Entry  Thu Oct 7 11:11:19 2021, Philipp Gaggl, Pad Sensoren, 32, SiC+Si, 120, , Carbon, , Unknown, , , 10, , , , ,  

beamtime on 18.09.2021
CH1: SiC
CH3: Si
Bias_Si: -100 V
Bias_SiC: 600 V

Entry  Thu Oct 7 11:11:42 2021, Philipp Gaggl, Pad Sensoren, 33, SiC+Si, 120, , Carbon, , Unknown, , , 10, , , , ,  

beamtime on 18.09.2021
CH1: SiC
CH3: Si
Bias_Si: -100 V
Bias_SiC: 400 V

Entry  Thu Oct 7 11:12:10 2021, Philipp Gaggl, Pad Sensoren, 34, SiC+Si, 62.4, , Proton, , Unknown, , , 10, , , , ,  

beamtime on 18.09.2021
CH1: SiC
CH3: Si
Bias_Si: -100 V
Bias_SiC: 400 V

Entry  Thu Oct 7 11:12:44 2021, Philipp Gaggl, Pad Sensoren, 35, SiC+Si, 62.4, , Proton, , Unknown, , , 10, , , , ,  

beamtime on 18.09.2021
CH1: SiC
CH3: Si
Bias_Si: -100 V
Bias_SiC: 600 V

Entry  Thu Oct 7 11:13:05 2021, Philipp Gaggl, Pad Sensoren, 36, SiC+Si, 62.4, , Proton, , Unknown, , , 10, , , , ,  

beamtime on 18.09.2021
CH1: SiC
CH3: Si
Bias_Si: -100 V
Bias_SiC: 800 V

Entry  Thu Oct 7 11:13:21 2021, Philipp Gaggl, Pad Sensoren, 37, SiC+Si, 62.4, , Proton, , Unknown, , , 10, , , , ,  

beamtime on 18.09.2021
CH1: SiC
CH3: Si
Bias_Si: -100 V
Bias_SiC: 1100 V

Entry  Sun Nov 7 19:00:54 2021, Felix Ulrich-Pur, Peakfinder WET meas 7.11.21, 13, , 175.3, nominal, , , Good, , , 10, , , , none,  

Start: 08:30
WET measurement of PMMA slabs also used for TOF-CT (GSI)

coarse run (to find Bragg range

Entry  Sun Nov 7 19:02:25 2021, Felix Ulrich-Pur, Peakfinder WET meas 7.11.21, 14, , 175.3, nominal, , , Good, , , 10, , , , none,  

Start: 08:55
WET measurement of PMMA slabs also used for TOF-CT (GSI)

reference run (with Arduino Spill Start/Stop logic)
fringes in Bragg peak (trigger not optimal (maybe too much latency with Arduino))--> next measurement with "Accumalte Charge" instead of "Spill Start/Stop"

Entry  Sun Nov 7 19:04:10 2021, Felix Ulrich-Pur, Peakfinder WET meas 7.11.21, 15, , 175.3, nominal, , , Good, , , 10, , , , none,  

Start: 09:14
WET measurement of PMMA slabs also used for TOF-CT (GSI)

reference run
"Accumalte Charge"

Entry  Sun Nov 7 19:05:15 2021, Felix Ulrich-Pur, Peakfinder WET meas 7.11.21, 16, , 175.3, nominal, , , Good, , , 10, , , , none,  

Start: 09:38
WET measurement of PMMA slabs also used for TOF-CT (GSI)

1cm PMMA
"Accumalte Charge"

PMMA was activated. Had to wait ~10-15min after measurement

Entry  Sun Nov 7 19:06:06 2021, Felix Ulrich-Pur, Peakfinder WET meas 7.11.21, 17, , 175.3, nominal, , , Good, , , 10, , , , none,  

Start: 10:06
WET measurement of PMMA slabs also used for TOF-CT (GSI)

2cm PMMA
"Accumalte Charge"

PMMA was activated. Had to wait ~10-15min after measurement

ELOG V3.1.5-fc6679b