Sat Feb 27 19:01:26 2021, Felix Ulrich-Pur, Waveforms SiC+Si, 23, SiC+Si+RaMon, 400.8, nominal, Carbon, , Good, , , 10, , , , ,
|
Start 14:18
14:30 enter room request: abbau and shielding was activated, called RP, removed SiC+Si Setup+Al shielding of DSSDs
Degrader 10, Carbon
Messung bis 14:24
danach neue Aufzeichnung (Hintergrundstrahlung) Start ca 14:25
channel 1 : Si upstream
channel 2: SiC downstream
400 V Bias
Referenz: 2.100 V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.477V channel 1, 0-Level: 2.315V channel 1
position:
x = 8
y = 68 |
Tue Mar 16 15:10:11 2021, Patrick Sieberer, Pad Sensoren, 24, , 252.7, nominal, Proton, , Good, , , 10, , , , none,
|
Start: 13:57
Range Shifter Out, Filter 1 IN, Filter 2 IN |
Sun Jun 20 19:40:12 2021, Felix Ulrich-Pur, HADES increased rate , 10, HADES-LGADs, 800, nominal, Proton, , Good, , , 10, , , , none, 0
|
TB 19.6.21
Start 21:50
Nominal flux degrader 10: mean rate O(200MHz)
|
Sun Jun 20 20:05:38 2021, Felix Ulrich-Pur, HADES testrun with increased rate 800MeV, 17, HADES-LGADs, 800, nominal, Proton, , Good, , , 10, , , , none, 0
|
TB 20.6.21
Start 20:10
Mean rate O(200MHz)
|
Thu Oct 7 11:03:37 2021, Philipp Gaggl, Pad Sensoren, 27, SiC+Si, 120, , Carbon, , Unknown, , , 10, , , , ,
|
beamtime on 18.09.2021
CH1: SiC
CH3: Si
Bias_Si: -100 V
Bias_SiC: 1100 V |
Thu Oct 7 11:07:08 2021, Philipp Gaggl, Pad Sensoren, 28, SiC+Si, 402.8, , Carbon, , Unknown, , , 10, , , , ,
|
beamtime on 18.09.2021
CH1: SiC
CH3: Si
Bias_Si: -100 V
Bias_SiC: 1100 V |
Thu Oct 7 11:08:16 2021, Philipp Gaggl, Pad Sensoren, 29, SiC+Si, 213.4, , Carbon, , Unknown, , , 10, , , , ,
|
beamtime on 18.09.2021
CH1: SiC
CH3: Si
Bias_Si: -100 V
Bias_SiC: 1100 V |
Thu Oct 7 11:08:51 2021, Philipp Gaggl, Pad Sensoren, 30, SiC+Si, 306.2, , Carbon, , Unknown, , , 10, , , , ,
|
beamtime on 18.09.2021
CH1: SiC
CH3: Si
Bias_Si: -100 V
Bias_SiC: 1100 V |
Thu Oct 7 11:10:54 2021, Philipp Gaggl, Pad Sensoren, 31, SiC+Si, 120, , Carbon, , Unknown, , , 10, , , , ,
|
beamtime on 18.09.2021
CH1: SiC
CH3: Si
Bias_Si: -100 V
Bias_SiC: 800 V |
Thu Oct 7 11:11:19 2021, Philipp Gaggl, Pad Sensoren, 32, SiC+Si, 120, , Carbon, , Unknown, , , 10, , , , ,
|
beamtime on 18.09.2021
CH1: SiC
CH3: Si
Bias_Si: -100 V
Bias_SiC: 600 V |
Thu Oct 7 11:11:42 2021, Philipp Gaggl, Pad Sensoren, 33, SiC+Si, 120, , Carbon, , Unknown, , , 10, , , , ,
|
beamtime on 18.09.2021
CH1: SiC
CH3: Si
Bias_Si: -100 V
Bias_SiC: 400 V |
Thu Oct 7 11:12:10 2021, Philipp Gaggl, Pad Sensoren, 34, SiC+Si, 62.4, , Proton, , Unknown, , , 10, , , , ,
|
beamtime on 18.09.2021
CH1: SiC
CH3: Si
Bias_Si: -100 V
Bias_SiC: 400 V |
Thu Oct 7 11:12:44 2021, Philipp Gaggl, Pad Sensoren, 35, SiC+Si, 62.4, , Proton, , Unknown, , , 10, , , , ,
|
beamtime on 18.09.2021
CH1: SiC
CH3: Si
Bias_Si: -100 V
Bias_SiC: 600 V |
Thu Oct 7 11:13:05 2021, Philipp Gaggl, Pad Sensoren, 36, SiC+Si, 62.4, , Proton, , Unknown, , , 10, , , , ,
|
beamtime on 18.09.2021
CH1: SiC
CH3: Si
Bias_Si: -100 V
Bias_SiC: 800 V |
Thu Oct 7 11:13:21 2021, Philipp Gaggl, Pad Sensoren, 37, SiC+Si, 62.4, , Proton, , Unknown, , , 10, , , , ,
|
beamtime on 18.09.2021
CH1: SiC
CH3: Si
Bias_Si: -100 V
Bias_SiC: 1100 V |
Sun Nov 7 19:00:54 2021, Felix Ulrich-Pur, Peakfinder WET meas 7.11.21, 13, , 175.3, nominal, , , Good, , , 10, , , , none,
|
Start: 08:30
WET measurement of PMMA slabs also used for TOF-CT (GSI)
coarse run (to find Bragg range |
Sun Nov 7 19:02:25 2021, Felix Ulrich-Pur, Peakfinder WET meas 7.11.21, 14, , 175.3, nominal, , , Good, , , 10, , , , none,
|
Start: 08:55
WET measurement of PMMA slabs also used for TOF-CT (GSI)
reference run (with Arduino Spill Start/Stop logic)
fringes in Bragg peak (trigger not optimal (maybe too much latency with Arduino))--> next measurement with "Accumalte Charge" instead of "Spill Start/Stop" |
Sun Nov 7 19:04:10 2021, Felix Ulrich-Pur, Peakfinder WET meas 7.11.21, 15, , 175.3, nominal, , , Good, , , 10, , , , none,
|
Start: 09:14
WET measurement of PMMA slabs also used for TOF-CT (GSI)
reference run
"Accumalte Charge" |
Sun Nov 7 19:05:15 2021, Felix Ulrich-Pur, Peakfinder WET meas 7.11.21, 16, , 175.3, nominal, , , Good, , , 10, , , , none,
|
Start: 09:38
WET measurement of PMMA slabs also used for TOF-CT (GSI)
1cm PMMA
"Accumalte Charge"
PMMA was activated. Had to wait ~10-15min after measurement |
Sun Nov 7 19:06:06 2021, Felix Ulrich-Pur, Peakfinder WET meas 7.11.21, 17, , 175.3, nominal, , , Good, , , 10, , , , none,
|
Start: 10:06
WET measurement of PMMA slabs also used for TOF-CT (GSI)
2cm PMMA
"Accumalte Charge"
PMMA was activated. Had to wait ~10-15min after measurement |
|