Sat Dec 11 17:46:17 2021, Felix Ulrich-Pur, Alignment run, 1, DSSD-Tracker, 800, V, Proton, , Good, , , , , , , none,
|
Fluence loss measurement 11.12.2021
Start 14:45
|
Sat Dec 11 17:47:45 2021, Felix Ulrich-Pur, Alignment run, 2, DSSD-Tracker, 800, V, Proton, , Good, , , , , , , none,
|
Fluence loss measurement 11.12.2021
|
Sat Dec 11 17:47:52 2021, Felix Ulrich-Pur, Alignment run, 3, DSSD-Tracker, 800, V, Proton, , Good, , , , , , , none,
|
Fluence loss measurement 11.12.2021
|
Sat Dec 11 17:48:08 2021, Felix Ulrich-Pur, Fluence loss 1cm, 4, DSSD-Tracker, 800, V, Proton, , Good, , , , , , , Alu, 0 deg
|
Fluence loss measurement 11.12.2021
Start 15:15
0deg =1cm Alu |
Sat Dec 11 18:19:56 2021, Felix Ulrich-Pur, Fluence loss 1cm, 5, DSSD-Tracker, 800, V, Proton, , Good, , , , , , , Alu, 0 deg
|
Fluence loss measurement 11.12.2021
Start 18:17
90deg = all five steps Alu |
Sat Oct 8 07:11:03 2022, Christian Irmler, Ramon only, 1, RD50-MPW3, 800, , Proton, , Crap, lowflux high, , , , , , ,
|
|
Sat Oct 8 07:20:45 2022, Christian Irmler, testrun ramon + tracker + DUT, 2, RD50-MPW3, 800, , , , Crap, lowflux high, , , , , , ,
|
Tracker timing wrong, latency too low, peak at 0 --> changed lat from 40 to 41 for next run. |
Sat Oct 8 07:28:42 2022, Christian Irmler, testrun ramon + tracker + DUT, 3, RD50-MPW3, 800, , , , Unknown, lowflux high, , , , , , ,
|
Tracker latency lat=42 |
Sat Oct 8 07:30:37 2022, Christian Irmler, testrun ramon + tracker + DUT, 4, RD50-MPW3, 800, , , , Unknown, lowflux high, , , , , , ,
|
Tracker latency lat=42
RD50-MPW3 monitor connected first |
Sat Oct 8 07:40:51 2022, Christian Irmler, ramon + tracker + DUT, 5, RD50-MPW3, 800, , , 24260338, Good, lowflux high, , , , , , ,
|
Tracker latency lat=42
First data run w/ ramon + tracker + MPW3 + monitor connected
Tracker dropped some udp packages, total tracker events 23166448 |
Sun Jan 10 06:40:06 2021, Maximilian Tomaschek, Lowflux recommissioning, 7, Ramon+Tracker, 62.4, , , 30 spills, , 10%, , 10, 1, , , ,
|
Rate, up till now looks like the same |
Sun Jan 10 06:44:59 2021, Maximilian Tomaschek, Lowflux recommissioning, 9, Ramon+Tracker, 62.4, , , 30 spills, , , , 10, 1, , 2, ,
|
Rate, Beta nominal, factor 10 too high |
Sun Jan 10 06:52:09 2021, Maximilian Tomaschek, Lowflux recommissioning, 16, Ramon+Tracker, 62.4, , , 30 spills, , 10%, , 10, 1, , 2, ,
|
Rate, now Beta 10% |
Sun Jan 10 07:17:44 2021, Maximilian Tomaschek, Lowflux recommissioning, 25, Ramon+Tracker, 62.4, , , 30 spills, Crap, , , 10, 1, , 0, ,
|
Rate, Beta nominal, no tracker data |
Sun Jan 10 07:24:28 2021, Maximilian Tomaschek, Lowflux recommissioning, 35, Ramon+Tracker, 62.4, , , 10 spills 1e6 events, Good, 10%, , 10, 1, , , ,
|
Spotsize |
Sun Jan 10 07:27:55 2021, Maximilian Tomaschek, Lowflux recommissioning, 47, Ramon+Tracker, 62.4, , , 7 spills 1e6 events, Good, , , 10, 1, , 0, ,
|
Spotsize, max T 1 & BSY 50 -> rate zu hoch |
Sun Jan 10 07:32:46 2021, Maximilian Tomaschek, Lowflux recommissioning, 54, Ramon+Tracker, 62.4, , , 40 spills 350k events, Good, 10%, , 10, 1, , 2, ,
|
Spotsize |
Sat Feb 27 09:26:27 2021, Felix Ulrich-Pur, Rate verification, 1, SiC+Si+RaMon, 62.4, III(EFE+SID2), , , Unknown, , , , , , , ,
|
Start 06:37
rate looks okish. few emtpy spills
|
Sat Feb 27 09:30:32 2021, Felix Ulrich-Pur, Rate verification, 5, SiC+Si+RaMon, 62.4, III(EFE+SID2), , , Good, , , , , , , ,
|
Start 07:03
verified if run 1 was reliable-->Same results
|
Sat Feb 27 09:40:15 2021, Felix Ulrich-Pur, Rate verification, 7, SiC+Si+RaMon, 62.4, I(EFE+SID0), , , Good, , , , , , , ,
|
Start 07:40
rate looks fine, however operators mentioned, that CPD data might have been loaded incorrectly-->pause during run and reloaded (07:48), rate
seems unchanged |
|