  306   Sat Dec 11 17:46:17 2021 Felix Ulrich-PurAlignment run1DSSD-Tracker800VProton Good      none 

Fluence loss measurement 11.12.2021

Start 14:45

 

  307   Sat Dec 11 17:47:45 2021 Felix Ulrich-PurAlignment run2DSSD-Tracker800VProton Good      none 

Fluence loss measurement 11.12.2021

 

 

  308   Sat Dec 11 17:47:52 2021 Felix Ulrich-PurAlignment run3DSSD-Tracker800VProton Good      none 

Fluence loss measurement 11.12.2021

 

 

  309   Sat Dec 11 17:48:08 2021 Felix Ulrich-PurFluence loss 1cm4DSSD-Tracker800VProton Good      Alu0 deg

Fluence loss measurement 11.12.2021

Start 15:15

0deg =1cm Alu

  310   Sat Dec 11 18:19:56 2021 Felix Ulrich-PurFluence loss 1cm5DSSD-Tracker800VProton Good      Alu0 deg

Fluence loss measurement 11.12.2021

Start 18:17

90deg = all five steps Alu

  76   Sat Feb 27 09:26:27 2021 Felix Ulrich-PurRate verification1SiC+Si+RaMon62.4III(EFE+SID2)  Unknown        

Start 06:37
rate looks okish. few emtpy spills

 

2021-02-27, 06:07:

channel 1 : Si upstream
channel 2: SiC downstream

400 V Bias

Referenz: 2.475V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.112V channel 1, 0-Level: 2.315V channel 1

position:

x: 0
y: 0 

2021-02-27, 06:30:

Referenz: 2.477V channel 1
channel 2 unverändert
 

2021-02-27, 06:37:

Setting: 3 

Run 1: 6:37 62.4 MeV, Rate geringer als erwartet 

 

  77   Sat Feb 27 09:28:07 2021 Felix Ulrich-PurRate verification2SiC+Si+RaMon252.7III(EFE+SID2)  Crap        

Start 06:47
rate only 10Hz, stopped run, room request and rewired trigger.

NOTE: Problem was caused by operators: Optics were not set correctly after ramping up energy from 62.4 to 252.7, not trigger cable

 

channel 1 : Si upstream
channel 2: SiC downstream

400 V Bias

Referenz: 2.475V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.477V channel 1, 0-Level: 2.315V channel 1

position:

x: 0
y: 0 

  78   Sat Feb 27 09:29:41 2021 Felix Ulrich-PurRate verification4SiC+Si+RaMon252.7III(EFE+SID2)  Good        

Start 06:55
reallocated correctly, rate looks similar to old measurements now (kHz ish)

 

channel 1 : Si upstream
channel 2: SiC downstream

400 V Bias

Referenz: 2.475V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.477V channel 1, 0-Level: 2.315V channel 1

position:

x: 0
y: 0 

  79   Sat Feb 27 09:30:32 2021 Felix Ulrich-PurRate verification5SiC+Si+RaMon62.4III(EFE+SID2)  Good        

Start 07:03
verified if run 1 was reliable-->Same results

 

channel 1 : Si upstream
channel 2: SiC downstream

400 V Bias

Referenz: 2.475V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.477V channel 1, 0-Level: 2.315V channel 1

position:

x: 0
y: 0 

  87   Sat Feb 27 18:42:13 2021 Felix Ulrich-PurWaveforms SiC+Si13SiC+Si+RaMon252.7III(EFE+SID2)  Good        

Start 10:38
no signal in SiC

channel 1 : Si upstream
channel 2: SiC downstream

400 V Bias

Referenz: 2.100 V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.477V channel 1, 0-Level: 2.315V channel 1

position:

x = 8
y = 68

  88   Sat Feb 27 18:43:12 2021 Felix Ulrich-PurWaveforms SiC+Si14SiC+Si+RaMon145.4III(EFE+SID2)  Good        

Start 10:47

channel 1 : Si upstream
channel 2: SiC downstream

400 V Bias

Referenz: 2.100 V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.477V channel 1, 0-Level: 2.315V channel 1

position:

x = 8
y = 68

  89   Sat Feb 27 18:43:35 2021 Felix Ulrich-PurWaveforms SiC+Si15SiC+Si+RaMon100.4III(EFE+SID2)  Good        

Start 11:09

channel 1 : Si upstream
channel 2: SiC downstream

400 V Bias

Referenz: 2.100 V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.477V channel 1, 0-Level: 2.315V channel 1

position:

x = 8
y = 68

  146   Tue Mar 16 14:51:53 2021 Patrick SiebererPad Sensoren1 62.4III(EFE+SID2)Proton Unknown      none 

Start: 06:38
Range Shifter Out, Filter 1 IN, Filter 2 IN
Scintillators in front

  147   Tue Mar 16 14:54:07 2021 Patrick SiebererPad Sensoren2 145.4III(EFE+SID2)Proton Good      none 

Start: 06:45
Range Shifter Out, Filter 1 IN, Filter 2 IN
Scintillators in front

  148   Tue Mar 16 14:54:40 2021 Patrick SiebererPad Sensoren3 252.7III(EFE+SID2)Proton Good      none 

Start: 07:00
Range Shifter Out, Filter 1 IN, Filter 2 IN
Scintillators in front

  149   Tue Mar 16 14:55:06 2021 Patrick SiebererPad Sensoren4 252.7III(EFE+SID2)Proton Good      none 

Start: 07:30
Range Shifter Out, Filter 1 IN, Filter 2 IN
Before the run we went inside to: put scintillators behind the sensors, reset the fpga counters

  150   Tue Mar 16 14:55:52 2021 Patrick SiebererPad Sensoren5 194.3III(EFE+SID2)Proton Good      none 

Start: 07:38
Range Shifter Out, Filter 1 IN, Filter 2 IN
Scintillators in front
 

  151   Tue Mar 16 14:56:22 2021 Patrick SiebererPad Sensoren6 145.4III(EFE+SID2)Proton Good      none 

Start: 07:42
Range Shifter Out, Filter 1 IN, Filter 2 IN

  152   Tue Mar 16 14:57:21 2021 Patrick SiebererPad Sensoren7 62.4III(EFE+SID2)Proton Good      none 

Start: 07:54
Range Shifter Out, Filter 1 IN, Filter 2 IN

  166   Tue Mar 16 15:07:56 2021 Patrick SiebererPad Sensoren21 100.4III(EFE+SID2)Proton Good      none 

Start: 12:41
Range Shifter Out, Filter 1 IN, Filter 2 IN
12:53 went inside to test if sensors are activated