Entry  Sat Oct 8 07:10:31 2022, Christian Irmler, RD50-MPW3 - First Testbeam, , , , , , , , , , , , , , ,  hvcmos_mpw3_20221008_TLU_00-000053.xml

Tracker xml file: hvcmos_mpw3_20221008_TLU_00-000053.xml

 

Entry  Sat Dec 11 18:19:56 2021, Felix Ulrich-Pur, Fluence loss 1cm, 5, DSSD-Tracker, 800, V, Proton, , Good, , , , , , , Alu, 0 deg 

Fluence loss measurement 11.12.2021

Start 18:17

90deg = all five steps Alu

Entry  Sat Dec 11 17:48:08 2021, Felix Ulrich-Pur, Fluence loss 1cm, 4, DSSD-Tracker, 800, V, Proton, , Good, , , , , , , Alu, 0 deg 

Fluence loss measurement 11.12.2021

Start 15:15

0deg =1cm Alu

Entry  Sat Dec 11 17:47:52 2021, Felix Ulrich-Pur, Alignment run, 3, DSSD-Tracker, 800, V, Proton, , Good, , , , , , , none,  

Fluence loss measurement 11.12.2021

 

 

Entry  Sat Dec 11 17:47:45 2021, Felix Ulrich-Pur, Alignment run, 2, DSSD-Tracker, 800, V, Proton, , Good, , , , , , , none,  

Fluence loss measurement 11.12.2021

 

 

Entry  Sat Dec 11 17:46:17 2021, Felix Ulrich-Pur, Alignment run, 1, DSSD-Tracker, 800, V, Proton, , Good, , , , , , , none,  

Fluence loss measurement 11.12.2021

Start 14:45

 

Entry  Sun Nov 21 14:53:00 2021, Simon Waid, Comparison SiC, Si, Si LGAD and Diamond, 4, Diamond+LGAD, 62.4, I(EFE+SID0), Proton, 100000, , , , , , , , ,  

Bias voltage Diamond: 500

Bias voltage Si LGAD: -100

From a beam perspective the Diamond detector was the first target, on oscilloscope channel 4, the Si LGAD was the second target connected to oscilloscope channel 1.

Triggering source was the Si LGAD detector.

Data was stored on the HiBPM-Osci-2 NUC under c:\measurements

Entry  Sun Nov 21 14:05:18 2021, Simon Waid, Comparison SiC, Si, Si LGAD and Diamond, 3, , 62.4, I(EFE+SID0), Proton, 10000, , , , , , , , ,  

Bias voltage SiC: 800

Bias voltage Si LGAD: -100

From a beam perspective the SiC detector was the first target, on oscilloscope channel 4, the Si LGAD was the second target connected to oscilloscope channel 1.

Triggering source was the Si LGAD detector. The SiC detector was most probably defective.

Data was stored on the HiBPM-Osci-2 NUC under c:\measurements

Entry  Sun Nov 21 13:55:05 2021, Simon Waid, Comparison SiC, Si, Si LGAD and Diamond, 2, SiC+Si, 62.4, I(EFE+SID0), Proton, 1000000, , , , , , , , ,  

Bias voltage SiC: 800

Bias voltage Si: -150

From a beam perspective the Si detector was the first target, on oscilloscope  channel 1, SiC was the second target connected to oscilloscope channel 3.

Triggering source was the Si detector.

The compliancy of the SiC SMU triggered after approx. 50% of the events had been acquired after this event the HV for the SiC HV was shut down.

Data was stored on the HiBPM-Osci-2 NUC under c:\measurements

Entry  Sun Nov 21 13:51:53 2021, Simon Waid, Comparison SiC, Si, Si LGAD and Diamond, 1, SiC+Si, 62.4, I(EFE+SID0), Proton, 10000, , , , , , , , ,  

Bias voltage SiC: 800

Bias voltage Si: -150

From a beam perspective the Si detector was the first target, on oscilloscope  channel 1, SiC was the second target connected to oscilloscope channel 3.

Triggering source was the SiC detector.

Data was stored on the HiBPM-Osci-2 NUC under c:\measurements

Entry  Sun Nov 7 21:04:43 2021, Felix Ulrich-Pur, Fluence loss meas 7.11.21, 30, , 100.4, II(BETA+EFE), Proton, 40e6, Good, , , , , , , none,  

Start: 21.04

reference run 100.4MeV

Entry  Sun Nov 7 19:28:49 2021, Felix Ulrich-Pur, Fluence loss meas 7.11.21, 29, Drehtisch, 100.4, II(BETA+EFE), Proton, 60e6, Good, , , , , , , Alu, 0 

Start: 19:28

1 cm Alu stair phantom on rotary table (0deg)

Entry  Sun Nov 7 19:13:36 2021, Felix Ulrich-Pur, Fluence loss meas 7.11.21, 28, Drehtisch, 100.4, II(BETA+EFE), Proton, 60e6, Good, , , , , , , Alu, 90 

Start: 18:00

1 cm Alu stair phantom on rotary table (90deg)

Entry  Sun Nov 7 19:12:57 2021, Felix Ulrich-Pur, Fluence loss meas 7.11.21, 27, Drehtisch, 145.4, II(BETA+EFE), Proton, 60e6, Good, , , , , , , Alu, 90 

Start: 16:40

1 cm Alu stair phantom on rotary table (90deg--> 0.2-1cm Alu)

Entry  Sun Nov 7 19:11:24 2021, Felix Ulrich-Pur, Fluence loss meas 7.11.21, 26, Drehtisch, 145.4, II(BETA+EFE), Proton, 60e6, Good, , , , , , , Alu, 0 

Start: 15:19

1 cm Alu stair phantom on rotary table (0deg--> always 1cm Al in beam)

Entry  Sun Nov 7 19:10:31 2021, Felix Ulrich-Pur, Fluence loss meas 7.11.21, 25, , 145.4, II(BETA+EFE), Proton, 40e6, Good, , , , , , , none,  

Start: 14:04

Reference run without phantom

Entry  Sun Nov 7 19:09:50 2021, Felix Ulrich-Pur, Fluence loss meas 7.11.21, 24, , 252.7, II(BETA+EFE), Proton, , Good, , , , , , , none,  

Start: 13:58

Alignment run without phantom

Entry  Sun Nov 7 19:08:47 2021, Felix Ulrich-Pur, Peakfinder WET meas 7.11.21, 22, , 194.3, nominal, , , Good, , , 10, , , , none,  

Start: 12:00
WET measurement of PMMA slabs also used for TOF-CT (GSI)

5cm PMMA. higher energy for Felix Feichtinger
"Accumalte Charge"

more detailed measurement

Entry  Sun Nov 7 19:07:31 2021, Felix Ulrich-Pur, Peakfinder WET meas 7.11.21, 21, , 194.3, nominal, , , Good, , , 10, , , , none,  

Start: 11:44
WET measurement of PMMA slabs also used for TOF-CT (GSI)

5cm PMMA. higher energy for Felix Feichtinger
"Accumalte Charge"

coarse run

Entry  Sun Nov 7 19:06:58 2021, Felix Ulrich-Pur, Peakfinder WET meas 7.11.21, 20, , 175.3, nominal, , , Good, , , 10, , , , none,  

Start: 11:24
WET measurement of PMMA slabs also used for TOF-CT (GSI)

5cm PMMA
"Accumalte Charge"

PMMA was activated. Had to wait ~10-15min after measurement