  324   Sat Oct 8 10:11:27 2022 Patrick Siebererramon + tracker + DUT14RD50-MPW3252.7   Goodlowflux low       ASIC: TH 1300   
  325   Sat Oct 8 10:16:45 2022 Patrick Siebererramon + tracker + DUT15RD50-MPW3252.7   Goodlowflux low       ASIC: TH 1300
BEAM OFF, for TH check
  
  326   Sat Oct 8 10:21:20 2022 Christian Irmlerramon + tracker + DUT16RD50-MPW3252.7   Goodlowflux low       ASIC: TH 1800 - too high, no noise hits
BEAM OFF, for TH check
  
  327   Sat Oct 8 10:24:12 2022 Christian Irmlerramon + tracker + DUT17RD50-MPW3252.7   Goodlowflux low       ASIC: TH 1600 - too high
BEAM OFF, for TH check
  
  328   Sat Oct 8 10:29:27 2022 Christian Irmlerramon + tracker + DUT18RD50-MPW3252.7   Goodlowflux low       ASIC: TH 1400
BEAM OFF, for TH check
  
  329   Sat Oct 8 10:30:38 2022 Christian Irmlerramon + tracker + DUT19RD50-MPW3252.7   Goodlowflux low       ASIC: TH 1300 again for verificationn -
still too many noise hits
BEAM OFF, for TH check
  
  330   Sat Oct 8 10:32:44 2022 Christian Irmlerramon + tracker + DUT20RD50-MPW3252.7   Craplowflux low       ASIC: TH 1350
BEAM OFF, for TH check

MPW3 monitor not connected -->
  
  331   Sat Oct 8 10:35:23 2022 Christian Irmlerramon + tracker + DUT21RD50-MPW3252.7   Craplowflux low       ASIC: TH 1350
BEAM OFF, for TH check

no noise hits
  
  332   Sat Oct 8 10:37:45 2022 Christian Irmlerramon + tracker + DUT22RD50-MPW3252.7   Unknownlowflux low       ASIC: TH 1330
BEAM OFF, for TH check

only few (1 or 2) pixel fire at
  
  333   Sat Oct 8 10:40:04 2022 Christian Irmlerramon + tracker + DUT23RD50-MPW3252.7   Unknownlowflux low       ASIC: TH 1330
BEAM ON all included

 
 
  
  334   Sat Oct 8 10:56:01 2022 Christian Irmlerramon + tracker + DUT24RD50-MPW3100.4   Unknownlowflux low       ASIC: TH 1330
BEAM ON all included

 
  
  335   Sat Oct 8 10:58:00 2022 Christian Irmlerramon + tracker + DUT25RD50-MPW3100.4   Unknownlowflux low       ASIC: TH 1310 seems to be okay
BEAM ON all included

2 GUIs started -> New Run
  
  336   Sat Oct 8 11:04:33 2022 Patrick Siebererramon + tracker + DUT26RD50-MPW3100.4   Unknownlowflux low       ASIC: TH 1310 seems to be okay
BEAM ON all included

 
  
  337   Sat Oct 8 11:12:05 2022 Patrick Siebererramon + tracker + DUT27RD50-MPW3100.4   Unknownlowflux high       ASIC: TH 1310 seems to be okay
BEAM ON all included

 
  
  338   Sat Oct 8 11:12:32 2022 Christian Irmlerramon + tracker + DUT28RD50-MPW3100.4   Unknownlowflux high       ASIC: TH 1310
BEAM OFF

 
  
  339   Sat Oct 8 11:30:26 2022 Patrick Siebererramon + tracker + DUT29RD50-MPW3100.4   Unknownlowflux high       ASIC: TH 1350
BEAM OFF

 
  
  340   Sat Oct 8 11:33:34 2022 Patrick Siebererramon + tracker + DUT30RD50-MPW3100.4   Unknownlowflux high       ASIC: TH 1350
BEAM ON

 
  
  341   Sat Oct 8 11:37:47 2022 Patrick Siebererramon + tracker + DUT31RD50-MPW3100.4   Unknownlowflux high       ASIC: TH 1340
BEAM ON

 
  
  342   Sat Oct 8 11:58:24 2022 Patrick Siebererramon + tracker + DUT32RD50-MPW3100.4   Unknownlowflux high       ASIC: TH 1330
BEAM ON

 
  
  343   Sat Oct 8 11:59:06 2022 Patrick Siebererramon + tracker + DUT33RD50-MPW3100.4   Unknownlowflux high       ASIC: TH 1330
BEAM ON

 
  