Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024
  MedAustron 2021, Page 16 of 18  Not logged in ELOG logo
ID Date Author Subject Run Numberup DUT Beam Energy Rate Setting Particle Type Events Data Beam Betatron Beam Chopper Beam Degrader Beam EFE Beam Orb Beam QuadScan PhantomType PhantomAngle Text Attachments
  115   Sat Feb 27 23:56:11 2021 Christian IrmlerE Scan DSSD+SiC73SiC+DSSD tracker145.4II(BETA+EFE)Proton5E5Good        Start 20:10:
Final MT=1, final BSY length =600
(2kHz), Trigger latency 41 optimal
  
  210   Tue Mar 16 15:35:10 2021 Patrick SiebererSiC strip sensor73SiC+DSSD tracker145.4II(BETA+EFE)Proton1MGood        Energy Scan
01:35
Filter vermutlich draussen
  
  65   Wed Jan 20 17:46:32 2021 Felix Ulrich-PurLowflux p800 commissioning74Ramon+Tracker800  30 spills 11%60.5%20306dB   MT=1, BSY=50,
potential setting VI

few outlier, fewer fluctuations
  
  116   Sat Feb 27 23:56:58 2021 Christian IrmlerE Scan DSSD+SiC74SiC+DSSD tracker800II(BETA+EFE)Proton3.1E6Good        Start 20:24:
Final MT=1, final BSY length =600
(2kHz), Trigger latency 41 optimal
  
  211   Tue Mar 16 15:35:35 2021 Patrick SiebererSiC strip sensor74SiC+DSSD tracker252.7II(BETA+EFE)Proton3MGood        Energy Scan
01:54
Filter vermutlich draussen
  
  66   Wed Jan 20 17:47:24 2021 Felix Ulrich-PurLowflux p800 commissioning75Ramon+Tracker800  30 spills 12%60.5%20306dB   MT=1, BSY=50,
setting VI

few outlier, fewer fluctuations
  
  117   Tue Mar 2 14:42:56 2021 Patrick SiebererMPW2 Tracking75MPW2+tracker252.7I(EFE+SID0)Proton Crap        Start xx:xx:

Tracker speed test: 2MHz internal
Trigger from TLU -> works.
  
  212   Tue Mar 16 15:35:59 2021 Patrick SiebererSiC strip sensor75SiC+DSSD tracker800VProton400kGood        Energy Scan
02:48
1-6M Hz!
  
  67   Wed Jan 20 17:47:53 2021 Felix Ulrich-PurLowflux p800 commissioning76Ramon+Tracker800  30 spills 100%60.5%20306dB   MT=1, BSY=50,

beam off
potential setting VII
  
  118   Tue Mar 2 14:45:04 2021 Patrick SiebererMPW2 Tracking76MPW2+tracker252.7I(EFE+SID0)Proton Crap        Start xx:xx:

Tracker speed test: 4MHz internal
Trigger from TLU -> works.
  
  213   Tue Mar 16 15:37:05 2021 Patrick SiebererSiC strip sensor76SiC+DSSD tracker800VIProton Crap        Energy Scan
03:02
4Hz, VII -> MHz ?
  
  68   Wed Jan 20 17:51:28 2021 Felix Ulrich-PurLowflux p800 commissioning77Ramon+Tracker800  30 spills 100%60.5%20306dB   MT=1, BSY=50,

beam off
potential setting VII
  
  214   Tue Mar 16 15:37:49 2021 Patrick SiebererSiC strip sensor77SiC+DSSD tracker800VProton6.6MGood        Energy Scan
03:06-5:18
MHz Rate
  
  119   Tue Mar 2 14:46:49 2021 Patrick SiebererMPW2 Tracking77-82MPW2+tracker252.7I(EFE+SID0)Proton Crap        Start 22:23 (Run79), 22:30, 22:37, 22:43 

Synchronization: Playing around
with trgger_busy (range 25-500) This slows
  
  69   Wed Jan 20 17:51:50 2021 Felix Ulrich-PurLowflux p800 commissioning79Ramon+Tracker800  30 spills 100%60.5%20306dB   MT=1, BSY=50

beam off
potential setting VII
  
  7   Sun Jan 10 06:42:03 2021 Maximilian TomaschekLowflux recommissioning8Ramon+Tracker252.7  30 spills   101 2  Rate, factor 10 too high, role ~30kHz instead
of 3kHz, Beta nominal
  
  82   Sat Feb 27 09:41:06 2021 Felix Ulrich-PurWaveforms SiC+Si8SiC+Si+RaMon252.7I(EFE+SID0)  Good        08:34 room request, PC for SiC had to be
restarted, trigger were connected as prior
to shift
  
  153   Tue Mar 16 14:57:41 2021 Patrick SiebererPad Sensoren8 62.4I(EFE+SID0)Proton Good      none Start: 08:20
Range Shifter Out, Filter 1 IN, Filter
2 IN
  
  234   Sun Jun 20 19:37:58 2021 Felix Ulrich-PurHADES energy run8HADES-LGADs62.4I(EFE+SID0)Proton Good      none0TB 19.6.21

Start 19:16
Mean rate O(MHz)
  
  280   Sun Nov 7 18:59:12 2021 Felix Ulrich-PurLow flux test 7.11.218 145.4II(BETA+EFE) 30 spillsGood      none Start: 07:20 O(100kHz)   
ELOG V3.1.5-fc6679b