  264   Thu Oct 7 11:08:51 2021 Philipp GagglPad Sensoren30SiC+Si306.2 Carbon Unknown  10     

beamtime on 18.09.2021
CH1: SiC
CH3: Si
Bias_Si: -100 V
Bias_SiC: 1100 V

  265   Thu Oct 7 11:10:54 2021 Philipp GagglPad Sensoren31SiC+Si120 Carbon Unknown  10     

beamtime on 18.09.2021
CH1: SiC
CH3: Si
Bias_Si: -100 V
Bias_SiC: 800 V

  266   Thu Oct 7 11:11:19 2021 Philipp GagglPad Sensoren32SiC+Si120 Carbon Unknown  10     

beamtime on 18.09.2021
CH1: SiC
CH3: Si
Bias_Si: -100 V
Bias_SiC: 600 V

  267   Thu Oct 7 11:11:42 2021 Philipp GagglPad Sensoren33SiC+Si120 Carbon Unknown  10     

beamtime on 18.09.2021
CH1: SiC
CH3: Si
Bias_Si: -100 V
Bias_SiC: 400 V

  268   Thu Oct 7 11:12:10 2021 Philipp GagglPad Sensoren34SiC+Si62.4 Proton Unknown  10     

beamtime on 18.09.2021
CH1: SiC
CH3: Si
Bias_Si: -100 V
Bias_SiC: 400 V

  269   Thu Oct 7 11:12:44 2021 Philipp GagglPad Sensoren35SiC+Si62.4 Proton Unknown  10     

beamtime on 18.09.2021
CH1: SiC
CH3: Si
Bias_Si: -100 V
Bias_SiC: 600 V

  270   Thu Oct 7 11:13:05 2021 Philipp GagglPad Sensoren36SiC+Si62.4 Proton Unknown  10     

beamtime on 18.09.2021
CH1: SiC
CH3: Si
Bias_Si: -100 V
Bias_SiC: 800 V

  271   Thu Oct 7 11:13:21 2021 Philipp GagglPad Sensoren37SiC+Si62.4 Proton Unknown  10     

beamtime on 18.09.2021
CH1: SiC
CH3: Si
Bias_Si: -100 V
Bias_SiC: 1100 V

  285   Sun Nov 7 19:00:54 2021 Felix Ulrich-PurPeakfinder WET meas 7.11.2113 175.3nominal  Good  10   none 

Start: 08:30
WET measurement of PMMA slabs also used for TOF-CT (GSI)

coarse run (to find Bragg range

  286   Sun Nov 7 19:02:25 2021 Felix Ulrich-PurPeakfinder WET meas 7.11.2114 175.3nominal  Good  10   none 

Start: 08:55
WET measurement of PMMA slabs also used for TOF-CT (GSI)

reference run (with Arduino Spill Start/Stop logic)
fringes in Bragg peak (trigger not optimal (maybe too much latency with Arduino))--> next measurement with "Accumalte Charge" instead of "Spill Start/Stop"

  287   Sun Nov 7 19:04:10 2021 Felix Ulrich-PurPeakfinder WET meas 7.11.2115 175.3nominal  Good  10   none 

Start: 09:14
WET measurement of PMMA slabs also used for TOF-CT (GSI)

reference run
"Accumalte Charge"

  288   Sun Nov 7 19:05:15 2021 Felix Ulrich-PurPeakfinder WET meas 7.11.2116 175.3nominal  Good  10   none 

Start: 09:38
WET measurement of PMMA slabs also used for TOF-CT (GSI)

1cm PMMA
"Accumalte Charge"

PMMA was activated. Had to wait ~10-15min after measurement

  289   Sun Nov 7 19:06:06 2021 Felix Ulrich-PurPeakfinder WET meas 7.11.2117 175.3nominal  Good  10   none 

Start: 10:06
WET measurement of PMMA slabs also used for TOF-CT (GSI)

2cm PMMA
"Accumalte Charge"

PMMA was activated. Had to wait ~10-15min after measurement

  290   Sun Nov 7 19:06:26 2021 Felix Ulrich-PurPeakfinder WET meas 7.11.2118 175.3nominal  Good  10   none 

Start: 10:30
WET measurement of PMMA slabs also used for TOF-CT (GSI)

3cm PMMA
"Accumalte Charge"

PMMA was activated. Had to wait ~10-15min after measurement

  291   Sun Nov 7 19:06:40 2021 Felix Ulrich-PurPeakfinder WET meas 7.11.2119 175.3nominal  Good  10   none 

Start: 11:00
WET measurement of PMMA slabs also used for TOF-CT (GSI)

4cm PMMA
"Accumalte Charge"

PMMA was activated. Had to wait ~10-15min after measurement

  292   Sun Nov 7 19:06:58 2021 Felix Ulrich-PurPeakfinder WET meas 7.11.2120 175.3nominal  Good  10   none 

Start: 11:24
WET measurement of PMMA slabs also used for TOF-CT (GSI)

5cm PMMA
"Accumalte Charge"

PMMA was activated. Had to wait ~10-15min after measurement

  293   Sun Nov 7 19:07:31 2021 Felix Ulrich-PurPeakfinder WET meas 7.11.2121 194.3nominal  Good  10   none 

Start: 11:44
WET measurement of PMMA slabs also used for TOF-CT (GSI)

5cm PMMA. higher energy for Felix Feichtinger
"Accumalte Charge"

coarse run

  294   Sun Nov 7 19:08:47 2021 Felix Ulrich-PurPeakfinder WET meas 7.11.2122 194.3nominal  Good  10   none 

Start: 12:00
WET measurement of PMMA slabs also used for TOF-CT (GSI)

5cm PMMA. higher energy for Felix Feichtinger
"Accumalte Charge"

more detailed measurement

  93   Sat Feb 27 18:50:16 2021 Felix Ulrich-PurWaveforms SiC+Si19SiC+Si+RaMon252.7nominal  Good  100     

Start 13:40

Degrader 100 
Messung aufgenommen, keine Screenshots

channel 1 : Si upstream
channel 2: SiC downstream

400 V Bias

Referenz: 2.100 V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.477V channel 1, 0-Level: 2.315V channel 1

position:

x = 8
y = 68

  96   Sat Feb 27 18:56:58 2021 Felix Ulrich-PurWaveforms SiC+Si22SiC+Si+RaMon252.7nominalProton Good  100     

Start 14:08

Degrader 100


channel 1 : Si upstream
channel 2: SiC downstream

400 V Bias

Referenz: 2.100 V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.477V channel 1, 0-Level: 2.315V channel 1

position:

x = 8
y = 68