Entry  Sun Nov 7 19:09:50 2021, Felix Ulrich-Pur, Fluence loss meas 7.11.21, 24, , 252.7, II(BETA+EFE), Proton, , Good, , , , , , , none,  

Start: 13:58

Alignment run without phantom

Entry  Sun Nov 7 19:10:31 2021, Felix Ulrich-Pur, Fluence loss meas 7.11.21, 25, , 145.4, II(BETA+EFE), Proton, 40e6, Good, , , , , , , none,  

Start: 14:04

Reference run without phantom

Entry  Sun Nov 7 21:04:43 2021, Felix Ulrich-Pur, Fluence loss meas 7.11.21, 30, , 100.4, II(BETA+EFE), Proton, 40e6, Good, , , , , , , none,  

Start: 21.04

reference run 100.4MeV

Entry  Sun Nov 21 13:51:53 2021, Simon Waid, Comparison SiC, Si, Si LGAD and Diamond, 1, SiC+Si, 62.4, I(EFE+SID0), Proton, 10000, , , , , , , , ,  

Bias voltage SiC: 800

Bias voltage Si: -150

From a beam perspective the Si detector was the first target, on oscilloscope  channel 1, SiC was the second target connected to oscilloscope channel 3.

Triggering source was the SiC detector.

Data was stored on the HiBPM-Osci-2 NUC under c:\measurements

Entry  Sun Nov 21 13:55:05 2021, Simon Waid, Comparison SiC, Si, Si LGAD and Diamond, 2, SiC+Si, 62.4, I(EFE+SID0), Proton, 1000000, , , , , , , , ,  

Bias voltage SiC: 800

Bias voltage Si: -150

From a beam perspective the Si detector was the first target, on oscilloscope  channel 1, SiC was the second target connected to oscilloscope channel 3.

Triggering source was the Si detector.

The compliancy of the SiC SMU triggered after approx. 50% of the events had been acquired after this event the HV for the SiC HV was shut down.

Data was stored on the HiBPM-Osci-2 NUC under c:\measurements

Entry  Sun Nov 21 14:05:18 2021, Simon Waid, Comparison SiC, Si, Si LGAD and Diamond, 3, , 62.4, I(EFE+SID0), Proton, 10000, , , , , , , , ,  

Bias voltage SiC: 800

Bias voltage Si LGAD: -100

From a beam perspective the SiC detector was the first target, on oscilloscope channel 4, the Si LGAD was the second target connected to oscilloscope channel 1.

Triggering source was the Si LGAD detector. The SiC detector was most probably defective.

Data was stored on the HiBPM-Osci-2 NUC under c:\measurements

Entry  Sun Nov 21 14:53:00 2021, Simon Waid, Comparison SiC, Si, Si LGAD and Diamond, 4, Diamond+LGAD, 62.4, I(EFE+SID0), Proton, 100000, , , , , , , , ,  

Bias voltage Diamond: 500

Bias voltage Si LGAD: -100

From a beam perspective the Diamond detector was the first target, on oscilloscope channel 4, the Si LGAD was the second target connected to oscilloscope channel 1.

Triggering source was the Si LGAD detector.

Data was stored on the HiBPM-Osci-2 NUC under c:\measurements

Entry  Sat Dec 11 17:46:17 2021, Felix Ulrich-Pur, Alignment run, 1, DSSD-Tracker, 800, V, Proton, , Good, , , , , , , none,  

Fluence loss measurement 11.12.2021

Start 14:45

 

Entry  Sat Dec 11 17:47:45 2021, Felix Ulrich-Pur, Alignment run, 2, DSSD-Tracker, 800, V, Proton, , Good, , , , , , , none,  

Fluence loss measurement 11.12.2021

 

 

Entry  Sat Dec 11 17:47:52 2021, Felix Ulrich-Pur, Alignment run, 3, DSSD-Tracker, 800, V, Proton, , Good, , , , , , , none,  

Fluence loss measurement 11.12.2021

 

 

Entry  Sat Oct 8 07:10:31 2022, Christian Irmler, RD50-MPW3 - First Testbeam, , , , , , , , , , , , , , ,  hvcmos_mpw3_20221008_TLU_00-000053.xml

Tracker xml file: hvcmos_mpw3_20221008_TLU_00-000053.xml

 

Entry  Sat Oct 8 07:11:03 2022, Christian Irmler, Ramon only, 1, RD50-MPW3, 800, , Proton, , Crap, lowflux high, , , , , , ,  
 
Entry  Sat Oct 8 07:20:45 2022, Christian Irmler, testrun ramon + tracker + DUT, 2, RD50-MPW3, 800, , , , Crap, lowflux high, , , , , , ,  

Tracker timing wrong, latency too low, peak at 0 --> changed lat from 40 to 41 for next run.

Entry  Sat Oct 8 07:28:42 2022, Christian Irmler, testrun ramon + tracker + DUT, 3, RD50-MPW3, 800, , , , Unknown, lowflux high, , , , , , ,  

Tracker latency lat=42

Entry  Sat Oct 8 07:30:37 2022, Christian Irmler, testrun ramon + tracker + DUT, 4, RD50-MPW3, 800, , , , Unknown, lowflux high, , , , , , ,  beam-profil-tracker.pngtiming_tracker.png

Tracker latency lat=42

RD50-MPW3 monitor connected first

Entry  Sat Oct 8 07:40:51 2022, Christian Irmler, ramon + tracker + DUT, 5, RD50-MPW3, 800, , , 24260338, Good, lowflux high, , , , , , ,  

Tracker latency lat=42

First data run w/ ramon + tracker + MPW3 + monitor connected

Tracker dropped some udp packages, total tracker events 23166448

Entry  Sat Oct 8 08:43:15 2022, Christian Irmler, ramon + tracker + DUT, 6, RD50-MPW3, 252.7, , , , Good, lowflux high, , , , , , ,  APV_sync_error.png

~4 MHz particle rate
MPW3 data file size after 5 minutes: 11 GB :-$

Tracker lost data again.
[2022-10-08 08:49:11 CEST]    Error::FADCGbEMerger::Event missmatch
[2022-10-08 08:49:11 CEST]    Error::FADCGbEMerger::Event missmatch
[2022-10-08 08:49:11 CEST]    Error::FADCGbEMerger::Event missmatch
[2022-10-08 08:49:11 CEST]    Error::FADCGbEMerger::Event missmatch
[2022-10-08 08:49:11 CEST]    Warning::UDPUnpacker::Expected package number 1953610, got: 1953990!
 

Sync-Error L5.1.1 and L5.1.2

Entry  Sat Oct 8 09:02:20 2022, Patrick Sieberer, ramon + tracker + DUT, 7, RD50-MPW3, 252.7, , , 5 min data taking, Good, lowflux high, , , , , , ,  

First data run w/ ramon + tracker + MPW3 + monitor connected

Entry  Sat Oct 8 09:07:48 2022, Patrick Sieberer, ramon + tracker + DUT, 8, RD50-MPW3, 252.7, , , kurz, Good, lowflux high, , , , , , ,  

short run for uploading to analysis

Entry  Sat Oct 8 09:08:13 2022, Patrick Sieberer, ramon + tracker + DUT, 9, RD50-MPW3, 252.7, , , kurz, Good, lowflux high, , , , , , ,  

TLU: 6,8M Tracker nur 4 M -> Let's reset FADC

ELOG V3.1.5-fc6679b