Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024
  MedAustron 2021, Page 16 of 18  Not logged in ELOG logo
ID Date Author Subject Run Number DUT Beam Energy Rate Setting Particle Type Events Data Beam Betatron Beam Chopper Beam Degrader Beam EFEdown Beam Orb Beam QuadScan PhantomType PhantomAngle
  301   Sun Nov 7 21:04:43 2021 Felix Ulrich-PurFluence loss meas 7.11.2130 100.4II(BETA+EFE)Proton40e6Good      none 

Start: 21.04

reference run 100.4MeV

  302   Sun Nov 21 13:51:53 2021 Simon WaidComparison SiC, Si, Si LGAD and Diamond1SiC+Si62.4I(EFE+SID0)Proton10000         

Bias voltage SiC: 800

Bias voltage Si: -150

From a beam perspective the Si detector was the first target, on oscilloscope  channel 1, SiC was the second target connected to oscilloscope channel 3.

Triggering source was the SiC detector.

Data was stored on the HiBPM-Osci-2 NUC under c:\measurements

  303   Sun Nov 21 13:55:05 2021 Simon WaidComparison SiC, Si, Si LGAD and Diamond2SiC+Si62.4I(EFE+SID0)Proton1000000         

Bias voltage SiC: 800

Bias voltage Si: -150

From a beam perspective the Si detector was the first target, on oscilloscope  channel 1, SiC was the second target connected to oscilloscope channel 3.

Triggering source was the Si detector.

The compliancy of the SiC SMU triggered after approx. 50% of the events had been acquired after this event the HV for the SiC HV was shut down.

Data was stored on the HiBPM-Osci-2 NUC under c:\measurements

  304   Sun Nov 21 14:05:18 2021 Simon WaidComparison SiC, Si, Si LGAD and Diamond3 62.4I(EFE+SID0)Proton10000         

Bias voltage SiC: 800

Bias voltage Si LGAD: -100

From a beam perspective the SiC detector was the first target, on oscilloscope channel 4, the Si LGAD was the second target connected to oscilloscope channel 1.

Triggering source was the Si LGAD detector. The SiC detector was most probably defective.

Data was stored on the HiBPM-Osci-2 NUC under c:\measurements

  305   Sun Nov 21 14:53:00 2021 Simon WaidComparison SiC, Si, Si LGAD and Diamond4Diamond+LGAD62.4I(EFE+SID0)Proton100000         

Bias voltage Diamond: 500

Bias voltage Si LGAD: -100

From a beam perspective the Diamond detector was the first target, on oscilloscope channel 4, the Si LGAD was the second target connected to oscilloscope channel 1.

Triggering source was the Si LGAD detector.

Data was stored on the HiBPM-Osci-2 NUC under c:\measurements

  306   Sat Dec 11 17:46:17 2021 Felix Ulrich-PurAlignment run1DSSD-Tracker800VProton Good      none 

Fluence loss measurement 11.12.2021

Start 14:45

 

  307   Sat Dec 11 17:47:45 2021 Felix Ulrich-PurAlignment run2DSSD-Tracker800VProton Good      none 

Fluence loss measurement 11.12.2021

 

 

  308   Sat Dec 11 17:47:52 2021 Felix Ulrich-PurAlignment run3DSSD-Tracker800VProton Good      none 

Fluence loss measurement 11.12.2021

 

 

  309   Sat Dec 11 17:48:08 2021 Felix Ulrich-PurFluence loss 1cm4DSSD-Tracker800VProton Good      Alu0 deg

Fluence loss measurement 11.12.2021

Start 15:15

0deg =1cm Alu

  310   Sat Dec 11 18:19:56 2021 Felix Ulrich-PurFluence loss 1cm5DSSD-Tracker800VProton Good      Alu0 deg

Fluence loss measurement 11.12.2021

Start 18:17

90deg = all five steps Alu

  311   Sat Oct 8 07:10:31 2022 Christian IrmlerRD50-MPW3 - First Testbeam               

Tracker xml file: hvcmos_mpw3_20221008_TLU_00-000053.xml

 

  312   Sat Oct 8 07:11:03 2022 Christian IrmlerRamon only1RD50-MPW3800 Proton Craplowflux high       
  313   Sat Oct 8 07:20:45 2022 Christian Irmlertestrun ramon + tracker + DUT2RD50-MPW3800   Craplowflux high       

Tracker timing wrong, latency too low, peak at 0 --> changed lat from 40 to 41 for next run.

  314   Sat Oct 8 07:28:42 2022 Christian Irmlertestrun ramon + tracker + DUT3RD50-MPW3800   Unknownlowflux high       

Tracker latency lat=42

  315   Sat Oct 8 07:30:37 2022 Christian Irmlertestrun ramon + tracker + DUT4RD50-MPW3800   Unknownlowflux high       

Tracker latency lat=42

RD50-MPW3 monitor connected first

  316   Sat Oct 8 07:40:51 2022 Christian Irmlerramon + tracker + DUT5RD50-MPW3800  24260338Goodlowflux high       

Tracker latency lat=42

First data run w/ ramon + tracker + MPW3 + monitor connected

Tracker dropped some udp packages, total tracker events 23166448

  317   Sat Oct 8 08:43:15 2022 Christian Irmlerramon + tracker + DUT6RD50-MPW3252.7   Goodlowflux high       

~4 MHz particle rate
MPW3 data file size after 5 minutes: 11 GB :-$

Tracker lost data again.
[2022-10-08 08:49:11 CEST]    Error::FADCGbEMerger::Event missmatch
[2022-10-08 08:49:11 CEST]    Error::FADCGbEMerger::Event missmatch
[2022-10-08 08:49:11 CEST]    Error::FADCGbEMerger::Event missmatch
[2022-10-08 08:49:11 CEST]    Error::FADCGbEMerger::Event missmatch
[2022-10-08 08:49:11 CEST]    Warning::UDPUnpacker::Expected package number 1953610, got: 1953990!
 

Sync-Error L5.1.1 and L5.1.2

  318   Sat Oct 8 09:02:20 2022 Patrick Siebererramon + tracker + DUT7RD50-MPW3252.7  5 min data takingGoodlowflux high       

First data run w/ ramon + tracker + MPW3 + monitor connected

  319   Sat Oct 8 09:07:48 2022 Patrick Siebererramon + tracker + DUT8RD50-MPW3252.7  kurzGoodlowflux high       

short run for uploading to analysis

  320   Sat Oct 8 09:08:13 2022 Patrick Siebererramon + tracker + DUT9RD50-MPW3252.7  kurzGoodlowflux high       

TLU: 6,8M Tracker nur 4 M -> Let's reset FADC

ELOG V3.1.5-fc6679b