Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024 testbeam-MA2025
  MedAustron 2021, Page 13 of 18  Not logged in ELOG logo
ID Date Author Subject Run Number DUT Beam Energy Rate Setting Particle Type Events Datadown Beam Betatron Beam Chopper Beam Degrader Beam EFE Beam Orb Beam QuadScan PhantomType PhantomAngle Text Attachments
  299   Sun Nov 7 19:13:36 2021 Felix Ulrich-PurFluence loss meas 7.11.2128Drehtisch100.4II(BETA+EFE)Proton60e6Good      Alu90Start: 18:00

1 cm Alu stair phantom on rotary
table (90deg)
  
  300   Sun Nov 7 19:28:49 2021 Felix Ulrich-PurFluence loss meas 7.11.2129Drehtisch100.4II(BETA+EFE)Proton60e6Good      Alu0Start: 19:28

1 cm Alu stair phantom on rotary
table (0deg)
  
  301   Sun Nov 7 21:04:43 2021 Felix Ulrich-PurFluence loss meas 7.11.2130 100.4II(BETA+EFE)Proton40e6Good      none Start: 21.04

reference run 100.4MeV
  
  306   Sat Dec 11 17:46:17 2021 Felix Ulrich-PurAlignment run1DSSD-Tracker800VProton Good      none Fluence loss measurement 11.12.2021

Start 14:45

 
  
  307   Sat Dec 11 17:47:45 2021 Felix Ulrich-PurAlignment run2DSSD-Tracker800VProton Good      none Fluence loss measurement 11.12.2021

 

 
  
  308   Sat Dec 11 17:47:52 2021 Felix Ulrich-PurAlignment run3DSSD-Tracker800VProton Good      none Fluence loss measurement 11.12.2021

 

 
  
  309   Sat Dec 11 17:48:08 2021 Felix Ulrich-PurFluence loss 1cm4DSSD-Tracker800VProton Good      Alu0 degFluence loss measurement 11.12.2021

Start 15:15

0deg =1cm Alu
  
  310   Sat Dec 11 18:19:56 2021 Felix Ulrich-PurFluence loss 1cm5DSSD-Tracker800VProton Good      Alu0 degFluence loss measurement 11.12.2021

Start 18:17

90deg = all five steps Alu
  
  316   Sat Oct 8 07:40:51 2022 Christian Irmlerramon + tracker + DUT5RD50-MPW3800  24260338Goodlowflux high       Tracker latency lat=42

First data run w/ ramon + tracker
+ MPW3 + monitor connected
  
  317   Sat Oct 8 08:43:15 2022 Christian Irmlerramon + tracker + DUT6RD50-MPW3252.7   Goodlowflux high       ~4 MHz particle rate
MPW3 data file size after 5 minutes:
11 GB :-$
 APV_sync_error.png 
  318   Sat Oct 8 09:02:20 2022 Patrick Siebererramon + tracker + DUT7RD50-MPW3252.7  5 min data takingGoodlowflux high       First data run w/ ramon + tracker + MPW3
+ monitor connected
  
  319   Sat Oct 8 09:07:48 2022 Patrick Siebererramon + tracker + DUT8RD50-MPW3252.7  kurzGoodlowflux high       short run for uploading to analysis   
  320   Sat Oct 8 09:08:13 2022 Patrick Siebererramon + tracker + DUT9RD50-MPW3252.7  kurzGoodlowflux high       TLU: 6,8M Tracker nur 4 M -> Let's
reset FADC
  
  321   Sat Oct 8 09:19:01 2022 Patrick Siebererramon + tracker + DUT10RD50-MPW3252.7   Goodlowflux high       repeat run 9

max_trgs: 100

tracker still not working.
 run9_hitmap_tracker.png 
  322   Sat Oct 8 09:33:59 2022 Patrick Siebererramon + tracker + DUT12RD50-MPW3252.7  9.8MGoodlowflux high       repeat run 9 again ;)

run 11 used for new local runs
of tracker - hvcmos_mpw3_20221008_11_TLU_00-000011.xml
  
  323   Sat Oct 8 09:46:15 2022 Patrick Siebererramon + tracker + DUT13RD50-MPW3252.7   Goodlowflux low       Ratenwechsel

Tracker: latency 42 > timing
much better
 timing_tracker_run13.pngtracker_hitmap_run9.png 
  324   Sat Oct 8 10:11:27 2022 Patrick Siebererramon + tracker + DUT14RD50-MPW3252.7   Goodlowflux low       ASIC: TH 1300   
  325   Sat Oct 8 10:16:45 2022 Patrick Siebererramon + tracker + DUT15RD50-MPW3252.7   Goodlowflux low       ASIC: TH 1300
BEAM OFF, for TH check
  
  326   Sat Oct 8 10:21:20 2022 Christian Irmlerramon + tracker + DUT16RD50-MPW3252.7   Goodlowflux low       ASIC: TH 1800 - too high, no noise hits
BEAM OFF, for TH check
  
  327   Sat Oct 8 10:24:12 2022 Christian Irmlerramon + tracker + DUT17RD50-MPW3252.7   Goodlowflux low       ASIC: TH 1600 - too high
BEAM OFF, for TH check
  
ELOG V3.1.5-fc6679b