Entry  Sun Nov 21 13:55:05 2021, Simon Waid, Comparison SiC, Si, Si LGAD and Diamond, 2, SiC+Si, 62.4, I(EFE+SID0), Proton, 1000000, , , , , , , , ,  

Bias voltage SiC: 800

Bias voltage Si: -150

From a beam perspective the Si detector was the first target, on oscilloscope  channel 1, SiC was the second target connected to oscilloscope channel 3.

Triggering source was the Si detector.

The compliancy of the SiC SMU triggered after approx. 50% of the events had been acquired after this event the HV for the SiC HV was shut down.

Data was stored on the HiBPM-Osci-2 NUC under c:\measurements

Entry  Sun Nov 21 14:05:18 2021, Simon Waid, Comparison SiC, Si, Si LGAD and Diamond, 3, , 62.4, I(EFE+SID0), Proton, 10000, , , , , , , , ,  

Bias voltage SiC: 800

Bias voltage Si LGAD: -100

From a beam perspective the SiC detector was the first target, on oscilloscope channel 4, the Si LGAD was the second target connected to oscilloscope channel 1.

Triggering source was the Si LGAD detector. The SiC detector was most probably defective.

Data was stored on the HiBPM-Osci-2 NUC under c:\measurements

Entry  Sun Nov 21 14:53:00 2021, Simon Waid, Comparison SiC, Si, Si LGAD and Diamond, 4, Diamond+LGAD, 62.4, I(EFE+SID0), Proton, 100000, , , , , , , , ,  

Bias voltage Diamond: 500

Bias voltage Si LGAD: -100

From a beam perspective the Diamond detector was the first target, on oscilloscope channel 4, the Si LGAD was the second target connected to oscilloscope channel 1.

Triggering source was the Si LGAD detector.

Data was stored on the HiBPM-Osci-2 NUC under c:\measurements

Entry  Sun Jan 10 06:27:26 2021, Maximilian Tomaschek, Lowflux recommissioning, 1, Ramon+Tracker, 252.7, , , 30 spills, , 10%, , 10, 1, , , ,  

Rate,15s spill pause, delay can be set by operator

Entry  Sun Jan 10 06:32:13 2021, Maximilian Tomaschek, Lowflux recommissioning, 2, Ramon+Tracker, 194.3, , , 30 spills, , 10%, , 10, 1, , , ,  

Rate

Entry  Sun Jan 10 06:33:22 2021, Maximilian Tomaschek, Lowflux recommissioning, 3, Ramon+Tracker, 175.3, , , 30 spills, , 10%, , 10, 1, , , ,  

Rate

Entry  Sun Jan 10 06:33:44 2021, Maximilian Tomaschek, Lowflux recommissioning, 5, Ramon+Tracker, 100.4, , , 30 spills, , 10%, , 10, 1, , , ,  

Rate

Entry  Sun Jan 10 06:38:16 2021, Maximilian Tomaschek, Lowflux recommissioning, 6, Ramon+Tracker, 83, , , 30 spills, , 10%, , 10, 1, , , ,  

Rate

Entry  Sun Jan 10 06:40:06 2021, Maximilian Tomaschek, Lowflux recommissioning, 7, Ramon+Tracker, 62.4, , , 30 spills, , 10%, , 10, 1, , , ,  

Rate, up till now looks like the same

Entry  Sun Jan 10 06:42:03 2021, Maximilian Tomaschek, Lowflux recommissioning, 8, Ramon+Tracker, 252.7, , , 30 spills, , , , 10, 1, , 2, ,  

Rate, factor 10 too high, role ~30kHz instead of 3kHz, Beta nominal

Entry  Sun Jan 10 06:44:59 2021, Maximilian Tomaschek, Lowflux recommissioning, 9, Ramon+Tracker, 62.4, , , 30 spills, , , , 10, 1, , 2, ,  

Rate, Beta nominal, factor 10 too high

Entry  Sun Jan 10 06:45:55 2021, Maximilian Tomaschek, Lowflux recommissioning, 10, Ramon+Tracker, 252.7, , , 30 spills, , 10%, , 10, 1, , 2, ,  

Rate, Beta 10% nominal, now 3kHz

Entry  Sun Jan 10 06:46:56 2021, Maximilian Tomaschek, Lowflux recommissioning, 11, Ramon+Tracker, 194.3, , , 30 spills, , 10%, , 10, 1, , 2, ,  

Rate, Beta 10% nominal

Entry  Sun Jan 10 06:50:45 2021, Maximilian Tomaschek, Lowflux recommissioning, 12, Ramon+Tracker, 175.3, , , 30 spills, , 10%, , 10, 1, , 2, ,  

Rate

Entry  Sun Jan 10 06:51:12 2021, Maximilian Tomaschek, Lowflux recommissioning, 14, Ramon+Tracker, 100.4, , , 30 spills, , 10%, , 10, 1, , 2, ,  

Rate, now Beta 10%

Entry  Sun Jan 10 06:51:57 2021, Maximilian Tomaschek, Lowflux recommissioning, 15, Ramon+Tracker, 83, , , 30 spills, , 10%, , 10, 1, , 2, ,  

Rate, now Beta 10%

Entry  Sun Jan 10 06:52:09 2021, Maximilian Tomaschek, Lowflux recommissioning, 16, Ramon+Tracker, 62.4, , , 30 spills, , 10%, , 10, 1, , 2, ,  

Rate, now Beta 10%

Entry  Sun Jan 10 06:52:24 2021, Maximilian Tomaschek, Lowflux recommissioning, 17, Ramon+Tracker, 252.7, , , 30 spills, , 10%, , 10, 1, , 0, ,  

Rate, now Beta 10%, looks like Beta EFE also ~400kHz

Entry  Sun Jan 10 07:01:04 2021, Maximilian Tomaschek, Lowflux recommissioning, 18, Ramon+Tracker, 252.7, , , 30 spills, , , , 10, 1, , 0, ,  

Rate, now Beta nominal again, looks like old setting 4-6 Mhz

Entry  Sun Jan 10 07:02:15 2021, Maximilian Tomaschek, Lowflux recommissioning, 19, Ramon+Tracker, 194.3, , , 30 spills, Crap, , , 10, 1, , 0, ,  

Rate, Beta nominal, ERROR tracker  -> reset TLU