Entry  Wed May 12 08:52:05 2021, Felix Ulrich-Pur, PMMA 0deg, 9, Drehtisch, 145.4, II(BETA+EFE), Proton, , Good, , , , , , , PMMA, 0 

TB 24.4.21

0deg (1cm PMMA)

timing was adjusted and FADC had to be restarted

Entry  Wed May 12 08:53:15 2021, Felix Ulrich-Pur, PMMA 90deg, 10, Drehtisch, 145.4, II(BETA+EFE), Proton, , Good, , , , , , , PMMA, 90 

TB 24.4.21

90deg (0.2-1cm PMMA)

Entry  Wed May 12 08:53:46 2021, Felix Ulrich-Pur, PMMA 90deg, 11, Drehtisch, 100.4, II(BETA+EFE), Proton, , Good, , , , , , , PMMA, 90 

TB 24.4.21

90deg (0.2-1cm PMMA)

Entry  Wed May 12 08:54:54 2021, Felix Ulrich-Pur, PMMA 0deg, 12, Drehtisch, 100.4, II(BETA+EFE), Proton, , Good, , , , , , , PMMA, 0 

TB 24.4.21

0deg (1cm PMMA)

Entry  Wed May 12 08:56:02 2021, Felix Ulrich-Pur, ABS 0deg, 13, Drehtisch, 145.4, II(BETA+EFE), Proton, , Good, , , , , , , ABS, 0 

TB 24.4.21

0deg (1cm ABS)

Entry  Wed May 12 08:56:37 2021, Felix Ulrich-Pur, ABS 0deg fluence loss, 15, Drehtisch, 145.4, II(BETA+EFE), Proton, , Good, , , , , , , ABS, 0 

TB 24.4.21

corrected trigger position for fluence loss radiography

0deg (1cm ABS)

Entry  Sun Jun 20 19:26:54 2021, Felix Ulrich-Pur, HADES testrun 800MeV, 1, HADES-LGADs, 800, VII, Proton, , Good, , , , , , , none, 0 

TB 19.6.21

Start 06:00
startet with wrong setting at the beginning (6 instead of 5) rate was then corrected, but RaMon was still running.

Final rate: 100kHz setting
07:24: room request: changed channel on board (was not connected to osci)

Entry  Sun Jun 20 19:30:28 2021, Felix Ulrich-Pur, HADES testrun 100.4MeV, 2, HADES-LGADs, 100.4, II(BETA+EFE), Proton, , Good, , , , , , , none, 0 

TB 19.6.21

Start 07:51
beam was paused at 10:10

bias run and threshold optimization

mean rate was O(100kHz)

Entry  Sun Jun 20 19:33:06 2021, Felix Ulrich-Pur, HADES testrun with increased rate 100.4MeV, 3, HADES-LGADs, 100.4, I(EFE+SID0), Proton, , Good, , , , , , , none, 0 

TB 19.6.21

Start 11:21
paused beam at 13:36
15:40-16:20 ECR source fail--downtime

Mean rate O(MHz)

Entry  Sun Jun 20 19:34:59 2021, Felix Ulrich-Pur, HADES energy run, 4, HADES-LGADs, 252.7, I(EFE+SID0), Proton, , Good, , , , , , , none, 0 

TB 19.6.21

Start 17:13

Mean rate O(MHz)
 

Entry  Sun Jun 20 19:35:46 2021, Felix Ulrich-Pur, HADES energy run, 5, HADES-LGADs, 194.3, I(EFE+SID0), Proton, , Good, , , , , , , none, 0 

TB 19.6.21

Start 17:42
Mean rate O(MHz)
 

Entry  Sun Jun 20 19:37:09 2021, Felix Ulrich-Pur, HADES energy run, 6, HADES-LGADs, 145.4, I(EFE+SID0), Proton, , Good, , , , , , , none, 0 

TB 19.6.21

Start 18:15
Mean rate O(MHz)
 

Entry  Sun Jun 20 19:37:37 2021, Felix Ulrich-Pur, HADES energy run, 7, HADES-LGADs, 83, I(EFE+SID0), Proton, , Good, , , , , , , none, 0 

TB 19.6.21

Start 18:48
Mean rate O(MHz)
 

Entry  Sun Jun 20 19:37:58 2021, Felix Ulrich-Pur, HADES energy run, 8, HADES-LGADs, 62.4, I(EFE+SID0), Proton, , Good, , , , , , , none, 0 

TB 19.6.21

Start 19:16
Mean rate O(MHz)
 

Entry  Sun Jun 20 19:38:28 2021, Felix Ulrich-Pur, HADES increased rate run (wrong setting, 9, HADES-LGADs, 800, VII, Proton, , Good, , , 20, , , , none, 0 

TB 19.6.21

Start 19:43
rate setting was not set correctly deg20 in combination with setting VII instead of nominal flux deg10
 

Entry  Sun Jun 20 19:40:12 2021, Felix Ulrich-Pur, HADES increased rate , 10, HADES-LGADs, 800, nominal, Proton, , Good, , , 10, , , , none, 0 

TB 19.6.21

Start 21:50

Nominal flux degrader 10: mean rate O(200MHz)
 

Entry  Sun Jun 20 19:50:11 2021, Felix Ulrich-Pur, HADES sandwich TOF, 11, HADES-LGADs+PMMAslabs, 100.4, I(EFE+SID0), Proton, , Good, , , , , , , PMMA, 0 

TB 20.6.21

Start 15:00 (late handover and copying of data)
5cm Phantom thickness
Mean rate O(MHz)

signal in last 2 LGADs too high (only 52MeV residual energy after 5cm)
 

Entry  Sun Jun 20 19:54:37 2021, Felix Ulrich-Pur, HADES sandwich TOF, 11, HADES-LGADs+PMMAslabs, 100.4, I(EFE+SID0), Proton, , Good, , , , , , , PMMA, 0 

TB 20.6.21

Start 15:55
5cm Phantom thickness
Mean rate O(MHz)
gain in last 2 layers was adapted
RamonRun 11 was not stopped (beam was still on from previous run)
for live TOF estimation: TDC3,channel 9 - TDC2,channel9
 

Entry  Sun Jun 20 19:55:47 2021, Felix Ulrich-Pur, HADES sandwich TOF reference run, 12, HADES-LGADs, 100.4, I(EFE+SID0), Proton, , Good, , , , , , , none, 0 

TB 20.6.21

Start 16:46
0cm Phantom thickness
Mean rate O(MHz)
reference run without phantom
for live TOF estimation: TDC3,channel 9 - TDC2,channel9
 

Entry  Sun Jun 20 19:58:31 2021, Felix Ulrich-Pur, HADES sandwich TOF, 13, HADES-LGADs+PMMAslabs, 100.4, I(EFE+SID0), Proton, , Good, , , , , , , PMMA, 0 

TB 20.6.21

Start 17:27
3cm Phantom thickness
Mean rate O(MHz)
for live TOF estimation: TDC3,channel 9 - TDC2,channel9
 