Entry  Sat Dec 11 17:46:17 2021, Felix Ulrich-Pur, Alignment run, 1, DSSD-Tracker, 800, V, Proton, , Good, , , , , , , none,  

Fluence loss measurement 11.12.2021

Start 14:45

 

Entry  Sat Dec 11 17:47:45 2021, Felix Ulrich-Pur, Alignment run, 2, DSSD-Tracker, 800, V, Proton, , Good, , , , , , , none,  

Fluence loss measurement 11.12.2021

 

 

Entry  Sat Dec 11 17:47:52 2021, Felix Ulrich-Pur, Alignment run, 3, DSSD-Tracker, 800, V, Proton, , Good, , , , , , , none,  

Fluence loss measurement 11.12.2021

 

 

Entry  Sat Dec 11 17:48:08 2021, Felix Ulrich-Pur, Fluence loss 1cm, 4, DSSD-Tracker, 800, V, Proton, , Good, , , , , , , Alu, 0 deg 

Fluence loss measurement 11.12.2021

Start 15:15

0deg =1cm Alu

Entry  Sat Dec 11 18:19:56 2021, Felix Ulrich-Pur, Fluence loss 1cm, 5, DSSD-Tracker, 800, V, Proton, , Good, , , , , , , Alu, 0 deg 

Fluence loss measurement 11.12.2021

Start 18:17

90deg = all five steps Alu

Entry  Sat Oct 8 07:11:03 2022, Christian Irmler, Ramon only, 1, RD50-MPW3, 800, , Proton, , Crap, lowflux high, , , , , , ,  
 
Entry  Sat Feb 27 19:01:26 2021, Felix Ulrich-Pur, Waveforms SiC+Si, 23, SiC+Si+RaMon, 400.8, nominal, Carbon, , Good, , , 10, , , , ,  

Start 14:18 

14:30 enter room request: abbau and shielding was activated, called RP, removed SiC+Si Setup+Al shielding of DSSDs

Degrader 10, Carbon
Messung bis 14:24

danach neue Aufzeichnung (Hintergrundstrahlung) Start ca 14:25


channel 1 : Si upstream
channel 2: SiC downstream

400 V Bias

Referenz: 2.100 V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.477V channel 1, 0-Level: 2.315V channel 1

position:

x = 8
y = 68

Entry  Thu Oct 7 11:03:37 2021, Philipp Gaggl, Pad Sensoren, 27, SiC+Si, 120, , Carbon, , Unknown, , , 10, , , , ,  

beamtime on 18.09.2021
CH1: SiC
CH3: Si
Bias_Si: -100 V
Bias_SiC: 1100 V

Entry  Thu Oct 7 11:07:08 2021, Philipp Gaggl, Pad Sensoren, 28, SiC+Si, 402.8, , Carbon, , Unknown, , , 10, , , , ,  

beamtime on 18.09.2021
CH1: SiC
CH3: Si
Bias_Si: -100 V
Bias_SiC: 1100 V

Entry  Thu Oct 7 11:08:16 2021, Philipp Gaggl, Pad Sensoren, 29, SiC+Si, 213.4, , Carbon, , Unknown, , , 10, , , , ,  

beamtime on 18.09.2021
CH1: SiC
CH3: Si
Bias_Si: -100 V
Bias_SiC: 1100 V

Entry  Thu Oct 7 11:08:51 2021, Philipp Gaggl, Pad Sensoren, 30, SiC+Si, 306.2, , Carbon, , Unknown, , , 10, , , , ,  

beamtime on 18.09.2021
CH1: SiC
CH3: Si
Bias_Si: -100 V
Bias_SiC: 1100 V

Entry  Thu Oct 7 11:10:54 2021, Philipp Gaggl, Pad Sensoren, 31, SiC+Si, 120, , Carbon, , Unknown, , , 10, , , , ,  

beamtime on 18.09.2021
CH1: SiC
CH3: Si
Bias_Si: -100 V
Bias_SiC: 800 V

Entry  Thu Oct 7 11:11:19 2021, Philipp Gaggl, Pad Sensoren, 32, SiC+Si, 120, , Carbon, , Unknown, , , 10, , , , ,  

beamtime on 18.09.2021
CH1: SiC
CH3: Si
Bias_Si: -100 V
Bias_SiC: 600 V

Entry  Thu Oct 7 11:11:42 2021, Philipp Gaggl, Pad Sensoren, 33, SiC+Si, 120, , Carbon, , Unknown, , , 10, , , , ,  

beamtime on 18.09.2021
CH1: SiC
CH3: Si
Bias_Si: -100 V
Bias_SiC: 400 V

Entry  Sun Jan 10 06:27:26 2021, Maximilian Tomaschek, Lowflux recommissioning, 1, Ramon+Tracker, 252.7, , , 30 spills, , 10%, , 10, 1, , , ,  

Rate,15s spill pause, delay can be set by operator

Entry  Sun Jan 10 06:32:13 2021, Maximilian Tomaschek, Lowflux recommissioning, 2, Ramon+Tracker, 194.3, , , 30 spills, , 10%, , 10, 1, , , ,  

Rate

Entry  Sun Jan 10 06:33:22 2021, Maximilian Tomaschek, Lowflux recommissioning, 3, Ramon+Tracker, 175.3, , , 30 spills, , 10%, , 10, 1, , , ,  

Rate

Entry  Sun Jan 10 06:33:44 2021, Maximilian Tomaschek, Lowflux recommissioning, 5, Ramon+Tracker, 100.4, , , 30 spills, , 10%, , 10, 1, , , ,  

Rate

Entry  Sun Jan 10 06:38:16 2021, Maximilian Tomaschek, Lowflux recommissioning, 6, Ramon+Tracker, 83, , , 30 spills, , 10%, , 10, 1, , , ,  

Rate

Entry  Sun Jan 10 06:40:06 2021, Maximilian Tomaschek, Lowflux recommissioning, 7, Ramon+Tracker, 62.4, , , 30 spills, , 10%, , 10, 1, , , ,  

Rate, up till now looks like the same