ID Date Author Subject Run Number DUT Beam Energydown Beam Betatron Beam Chopper Beam Degrader Beam EFE Beam Orb Beam QuadScan PhantomType PhantomAngle Events Data
  288   Sun Dec 6 16:53:35 2020 Christian IrmlerMPW2207W13_04252.7   1 SID0 HV = 80V10 spills 

pixel scan, starting with r3 c3

tried to syncronized clocks of Caribou and TLU syncronized before run started.
clock of caribou is still 3s ahead. --> need to use ntp server next time.

was interrupted between spill 64 an 65 for about 40 minutes due to MAPTA error (HL-tank error)

stopped after r7 c7

  289   Sun Dec 6 18:59:48 2020 Christian IrmlerMPW2208W13_04252.7   1 SID0 HV = 80V10 spills 

single pixel r0 c2

shutter time set to 2.5s (half of previous value)

  290   Sun Dec 6 19:07:20 2020 Christian IrmlerMPW2209W13_04252.7   1 SID0 HV = 80V10 spills 

single pixel r0 c2

shutter time set to 6s 

  291   Sun Dec 6 19:29:57 2020 Christian IrmlerMPW2210W13_04252.71  1   HV = 80V10 spills 

single pixel r0 c2

test run for new beam settings

  292   Sun Dec 6 19:30:38 2020 Christian IrmlerMPW2211W13_04252.71  1   HV = 80V10 spills 

pixle scan, starting with r0 c0

stopped after r0 c6 due network error (oscilloscope connected)

beam rate ~400k

hit rate MPW2: ~400 hits per spill

  293   Sun Dec 6 19:51:49 2020 Christian IrmlerMPW2212W13_04252.71  1   HV = 80V10 spillsCrap

pixel scan, starting with r0 c7

stopped due to broken pipe

Caribou rebooted

Entry is currently edited by Felix Ulrich-Pur on 80.120.130.63    294   Sun Dec 6 20:04:27 2020 Christian IrmlerMPW2213W13_04252.71  1   HV = 80V10 spills 

pixel scan, starting with r0 c7

 

  23   Sun May 10 20:41:43 2020 Felix Ulrich-PurBeam+Diamond 500V21Diamond194.3nonenone EFE SID2none 150960 

Diamond
Dia HV = +/- 250V

ADC, FIR, ped, noise, cal

  119   Sat Jul 4 04:04:53 2020 Felix Ulrich-PurEFE SID0 spot-size measurement9Lynx+RaMon+Octavius194.3   yes SID0    

tested 90,60 and 30s exposure time of Lynx

  126   Sat Jul 4 04:16:09 2020 Felix Ulrich-PurBeta+EFE spot-size measurement16Lynx+RaMon+Octavius194.3yes  yes      

tested 180s exposure time of Lynx

  135   Sat Jul 4 04:48:19 2020 Felix Ulrich-PurEFE SID0 spot-size measurement25Lynx+RaMon+Octavius194.3   yes SID0    

 

 

  138   Sat Jul 4 05:42:48 2020 Felix Ulrich-PurEFE SID0 Energy measurement28Peakfinder194.3   yes SID0    

 

 

  121   Sat Jul 4 04:05:32 2020 Felix Ulrich-PurEFE SID0 spot-size measurement11Lynx+RaMon+Octavius175.3   yes SID0    

tested 30 and 20s exposure time of Lynx

  127   Sat Jul 4 04:16:25 2020 Felix Ulrich-PurBeta+EFE spot-size measurement17Lynx+RaMon+Octavius175.3yes  yes      

tested 180s exposure time of Lynx

  136   Sat Jul 4 05:05:16 2020 Felix Ulrich-PurEFE SID0 spot-size measurement26Lynx+RaMon+Octavius175.3   yes SID0    

 

 

  139   Sat Jul 4 05:43:29 2020 Felix Ulrich-PurEFE SID0 Energy measurement29Peakfinder175.3   yes SID0    

 

 

  50   Sat Jun 13 04:11:34 2020 Felix Ulrich-PurLinearity measurement TERA 145.4 gain 20024TERA-Cal145.4BETA  EFE  none 200000 

Linearity Messung Gain 200 10e5 rate

  51   Sat Jun 13 04:14:29 2020 Felix Ulrich-PurLinearity measurement TERA 145.4 gain 30025TERA-Cal145.4BETA  EFE  none 200000 

Linearity Messung Gain 300 10e5 rate

  52   Sat Jun 13 04:14:44 2020 Felix Ulrich-PurLinearity measurement TERA 145.4 gain 40026TERA-Cal145.4BETA  EFE  none 200000 

Linearity Messung Gain 400 10e5 rate

  54   Sat Jun 13 04:16:42 2020 Felix Ulrich-PurLinearity measurement TERA 145.4 gain 60027TERA-Cal145.4BETA  EFE  none 200000 

Linearity Messung Gain 700 10e5 rate