Home
CMS Production
Clean room
MedAustron
HEPHY
testbeams
old
testbeam-MA2018
testbeam-MA2019
testbeam-MA2020
testbeam-MA2021
testbeam-MA2023
testbeam-MA2024
MedAustron 2020, Page 15 of 15
Not logged in
Find
|
Login
|
Help
New entries since:
Thu Jan 1 01:00:00 1970
Full
| Summary |
Threaded
-- All entries --
Last day
Last 3 Days
Last week
Last month
Last 3 Months
Last 6 Months
Last Year
-- DUT --
common
DSSD-Tracker
TERA-Cal
MALTA
Drehtisch
Sketch
LGAD
Diamond + DSSD tracker
Diamond
Diamond + DSSD-pCT6
Peakfinder
Peakfinder+RaMon+Octavius+Film
Lynx+RaMon+Octavius+Film
Lynx+RaMon+Octavius
TERA+Tracker
RaMon
W13_04
Ramon+Tracker
-- Beam Energy --
800
252.7
145.4
100.4
83
62.4
194.3
Noise
125.41
73.28
175.3
100
-- PhantomType --
none
Alu
PMMA
PEEK
292 Entries
Goto page
Previous
1
,
2
,
3
...
13
,
14
, 15
All
ID
Date
Author
Subject
Run Number
DUT
Beam Energy
Beam Betatron
Beam Chopper
Beam Degrader
Beam EFE
Beam Orb
Beam QuadScan
PhantomType
PhantomAngle
Events
Data
Text
282
Sun Dec 6 15:45:45 2020
Christian Irmler
MPW2
201
W13_04
252.7
1
SID0
HV = 100V
10 spills
r0 c2
283
Sun Dec 6 15:53:12 2020
Christian Irmler
MPW2
202
W13_04
252.7
1
SID0
HV off
10 spills
r0 c2
HV set to 0V, but KeithRC SW turned
SMU output off
284
Sun Dec 6 15:55:13 2020
Christian Irmler
MPW2
203
W13_04
252.7
1
SID0
HV = 1V
10 spills
r0 c2
lowest Voltage, which could be
set with SMU outputs on.
285
Sun Dec 6 15:57:28 2020
Christian Irmler
MPW2
204
W13_04
252.7
1
SID0
HV = 20V
10 spills
r0 c2
286
Sun Dec 6 16:01:02 2020
Christian Irmler
MPW2
205
W13_04
252.7
1
SID0
HV = 80V
10 spills
pixel scan, starting with r0 c0
stopped after r1 c5 due to synch
issues
287
Sun Dec 6 16:32:54 2020
Christian Irmler
MPW2
206
W13_04
252.7
1
SID0
HV = 80V
10 spills
pixel scan, starting with r1 c6
stopped after r3 c2
stopped due to time difference
288
Sun Dec 6 16:53:35 2020
Christian Irmler
MPW2
207
W13_04
252.7
1
SID0
HV = 80V
10 spills
pixel scan, starting with r3 c3
tried to syncronized clocks of
Caribou and TLU syncronized before run started.
289
Sun Dec 6 18:59:48 2020
Christian Irmler
MPW2
208
W13_04
252.7
1
SID0
HV = 80V
10 spills
single pixel r0 c2
shutter time set to 2.5s (half
of previous value)
290
Sun Dec 6 19:07:20 2020
Christian Irmler
MPW2
209
W13_04
252.7
1
SID0
HV = 80V
10 spills
single pixel r0 c2
shutter time set to 6s
291
Sun Dec 6 19:29:57 2020
Christian Irmler
MPW2
210
W13_04
252.7
1
1
HV = 80V
10 spills
single pixel r0 c2
test run for new beam settings
292
Sun Dec 6 19:30:38 2020
Christian Irmler
MPW2
211
W13_04
252.7
1
1
HV = 80V
10 spills
pixle scan, starting with r0 c0
stopped after r0 c6 due network
error (oscilloscope connected)
294
Sun Dec 6 20:04:27 2020
Christian Irmler
MPW2
213
W13_04
252.7
1
1
HV = 80V
10 spills
pixel scan, starting with r0 c7
Goto page