Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024
  MedAustron 2020, Page 14 of 15  Not logged in ELOG logo
ID Date Author Subject Run Number DUT Beam Energy Beam Betatron Beam Chopper Beam Degrader Beam EFEdown Beam Orb Beam QuadScan PhantomType PhantomAngle Events Data
  6   Sun May 10 16:44:46 2020 Christian IrmlerCalibration Diamond 500V3Diamond252.7nonenone    none   

diamond only
Dia HV = +/- 250V

ADC, FIR, ped, noise, cal

  7   Sun May 10 16:47:10 2020 Christian IrmlerCalibration Diamond 600V4Diamond252.7nonenone    none   

diamond only
Dia HV = +/- 300V

ADC, FIR, ped, noise, cal

  9   Sun May 10 17:01:42 2020 Christian IrmlerCalibration Diamond + pCT-6 600V6Diamond + DSSD-pCT6252.7nonenone    none   

pCT-6 + diamond

DSSD HV = +/-50V
Dia HV = +/- 300V

ADC, FIR, ped, noise, cal

  10   Sun May 10 17:14:00 2020 Christian IrmlerCalibration Diamond + pCT-6 300V7Diamond + DSSD-pCT6252.7nonenone    none   

pCT-6 + diamond

DSSD HV = +/-50V
Dia HV = +/- 150V

ADC, FIR, ped, noise, cal

  11   Sun May 10 17:16:58 2020 Christian IrmlerCalibration Diamond 300V8Diamond252.7nonenone    none   

Diamond only
Dia HV = +/- 150V

ADC, FIR, ped, noise, cal

  12   Sun May 10 17:21:28 2020 Felix Ulrich-PurCalibration Diamond 400V9Diamond252.7nonenone    none   

Diamond only
Dia HV = +/- 200V

ADC, FIR, ped, noise, cal

  13   Sun May 10 17:38:55 2020 Felix Ulrich-PurCalibration Diamond+pCT6 400V10Diamond + DSSD-pCT6252.7nonenone    none   

Diamond+pCT6
Dia HV = +/- 200V

ADC, FIR, ped, noise, cal

  14   Sun May 10 17:44:50 2020 Felix Ulrich-PurCalibration Diamond+pCT6 500V11Diamond + DSSD-pCT6252.7nonenone    none   

Diamond+pCT6
Dia HV = +/- 250V

ADC, FIR, ped, noise, cal

  25   Sun May 10 22:21:11 2020 Felix Ulrich-PurCalibration Tracker+Diamond 500V24Diamond + DSSD tracker252.7nonenone    none   

Diamond+Tracker
Dia HV = +/- 250V

 

  92   Fri Jun 19 19:22:10 2020 Felix Ulrich-PurCalibration Diamond,Silimond,pCT6+Diamand30Diamond           

300V-800V in 100V steps

xml files:

/mnt/data/xmls/local/pct_dia_01_diamond_800V_02-000030.xml
/mnt/data/xmls/global/pct_dia_01_diamond_800V_beam_02-000030.xml

all calibration files

800 is only example replace with according voltage

  93   Sun Jun 21 05:31:37 2020 Felix Ulrich-PurSilimond31Diamond + DSSD trackerNoise          

local run

  108   Sun Jun 21 13:57:57 2020 Felix Ulrich-PurDiamond only 252.7 MeV 500V46Diamond252.7  10       

252.7 MeV 400MHz flux test: spill structure  in current visible

nominal flux degrader 10, random trigger

 

telescope shifted 6mm to the left (in beam direction)

 

  110   Sun Jun 21 14:17:34 2020 Felix Ulrich-PurSilimond 500V48DiamondNoise          

500 V run after high flux irradiation

 

  140   Sun Sep 20 06:09:28 2020 Alexander Burker2020-09-201TERA-Cal800      none   

800 MeV, "Setting 4"

 

  141   Sun Sep 20 06:43:10 2020 Alexander Burker2020-09-202TERA-Cal800      none   

800 MeV, "Setting 4"

Timeout stop

  142   Sun Sep 20 06:43:34 2020 Alexander Burker2020-09-203TERA-Cal800      none   

800 MeV, "Setting 4"

Calibration

  149   Sun Sep 20 09:14:06 2020 Alexander Burker 10           Crap

Timing in Tracker seems to be off

 

  156   Sat Oct 10 09:38:12 2020 Alexander Burker2020-10-102TERA-Cal800          

Start 06:58; "Setting 4", Calibration

 

  157   Sat Oct 10 09:39:02 2020 Alexander Burker2020-10-101TERA-Cal           

Start 06:25; Pedestal run

 

  161   Sat Oct 10 10:42:57 2020 Alexander Burker2020-10-107DSSD-Tracker       none   

Start 10:41; Local run tracker

XML file local runs: /mnt/data/xmls/local/pct_20201010_00-000007.xml
generated global xml file: /mnt/data/xmls/global/pct_20201010_00-000007.xml 
file data path manually set to /mnt/data/spy_data/global/

ELOG V3.1.5-fc6679b