ID Date Authordown Project Subject Run Number Events StartTime EndTime Data Text Attachments
  55   Thu Jan 9 23:27:27 2014 Markus FriedlAIDArunrun047100k09.01.2014 23:26:3510.01.2014 00:52:56GoodHV=80V  I=3.8uA
centered position, HV scan
5GeV beam, 6 samples
  
  56   Fri Jan 10 00:58:46 2014 Markus FriedlAIDArunrun048500k10.01.2014 00:57:4810.01.2014 08:17:57GoodHV=90V  I=3.9uA
centered position, HV scan
5GeV beam, 6 samples
  
  57   Fri Jan 10 08:21:46 2014 Markus FriedlAIDArunrun049100k10.01.2014 08:20:49 10.01.2014 09:49:46GoodHV=100V  I=4.2uA
centered position, HV scan
5GeV beam, 6 samples
  
  58   Fri Jan 10 09:54:11 2014 Markus FriedlAIDArunrun050100k10.01.2014 09:53:1310.01.2014 11:21:12GoodHV=110V  I=4.1uA
centered position, HV scan
5GeV beam, 6 samples
  
  59   Fri Jan 10 11:02:31 2014 Markus FriedlBelle SVDPower supply  10.01.2014 11:00:00 Unknown   KenWood100114.png 
  60   Fri Jan 10 11:26:54 2014 Markus FriedlAIDArunrun051100k10.01.2014 11:26:0810.01.2014 12:53:12GoodHV=120V  I=4.6uA
centered position, HV scan
5GeV beam, 6 samples
  
  61   Fri Jan 10 13:04:49 2014 Markus FriedlAIDArunrun052100k10.01.2014 13:04:0510.01.2014 14:30:18GoodHV=130V  I=4.6uA
centered position, HV scan
5GeV beam, 6 samples
  
  62   Sat Jan 11 20:56:29 2014 Markus FriedlAIDArunrun053100k11.01.2014 20:55:2911.01.2014 22:25:43GoodHV=140V  I=7.1uA
centered position, HV scan
5GeV beam, 6 samples
  
  63   Sat Jan 11 22:32:19 2014 Markus FriedlAIDArunrun054800k11.01.2014 22:30:4412.01.2014 10:13:10GoodHV=150V  I=5.3uA
centered position, HV scan
5GeV beam, 6 samples
  
  64   Sun Jan 12 10:36:37 2014 Markus FriedlAIDArunrun05531091312.01.2014 10:34:4412.01.2014 15:42:47GoodHV=100V  I=3.6uA
position = 23 / -35 mm relative to
before
  
  65   Sun Jan 12 18:04:18 2014 Markus FriedlAIDArunrun056510k12.01.2014 17:59:5713.01.2014 01:47:50GoodHV=100V  I=3.7uA
position = -25 / 0 mm relative to
initial
  
  66   Mon Jan 13 01:58:14 2014 Markus FriedlAIDArunrun057900k13.01.2014 01:56:2613.01.2014 10:48:22GoodHV=100V  I=3.7uA
position = 0 / -30 mm relative to
initial (but again centered)
  
  67   Mon Jan 13 12:02:40 2014 Markus FriedlcommonKontakt    UnknownRichard Thalmeier   Tel. 4801
Hao Yin   
  
  69   Thu Jan 23 22:47:49 2014 Hao Yin AIDACalibrationRun0018380023.01.2014 13:35:5523.01.2014 02:08:15Goodtaken with tuxdaq...
HV=75V  I=?3.7uA?
position = 0 / -30 mm relative to
  
  70   Fri Jan 24 00:21:16 2014 Hao Yin AIDAHW_AIDA00140k24.02.2014 00:18 UnknownHV=100V  I=3.7uA
position = 0 / -30 mm relative to
initial (but again centered) no idea ---
  
  72   Fri Jan 24 11:23:15 2014 Hao Yin AIDAHW_AIDA0037635624.02.2014 10:3024.02.2014 11:22UnknownHV=100V  I=3.7uA
position = 0 / -30 mm relative to
initial (but again centered) no idea ---
  
  68   Sun Jan 19 18:01:46 2014 Christian IrmlercommonAIDA setup operated with TuxDAQ    UnknownNew SIS driver version sis1100-2.13-3 installed
on DAQPC. 
To install the driver call as root:
  