85
|
Wed Jan 29 12:10:06 2014 |
Wolfgang Treberspurg | Infineon | Single mode Run Stack 2 Bias Scan | HW_Run_Infineon_Stack2_BiasScan_005 | 200k | 28.01.2014 20:00 | 28.01.2014 23:00 | Good |
HV at 210V; I at app. 8.5µA 3GeV, Single mode
|
86
|
Wed Jan 29 12:11:00 2014 |
Wolfgang Treberspurg | Infineon | Single mode Run Stack 2 Bias Scan | HW_Run_Infineon_Stack2_BiasScan_006 | 200k | 28.01.2014 20:30 | 28.01.2014 21:00 | Good |
HV at 220V; I at app. 8.5µA 3GeV, Single mode
|
87
|
Wed Jan 29 21:55:09 2014 |
Wolfgang Treberspurg | Infineon | Single mode Run Stack 2 Bias Scan | HW_Run_Infineon_Stack2_BiasScan_007 | 200k | 29.01.2014 11:50 | 29.01.2014 12:15 | Good |
HV at 230V; I at app. 8µA 3GeV, Single mode
|
88
|
Wed Jan 29 21:56:15 2014 |
Wolfgang Treberspurg | Infineon | Single mode Run Stack 2 Bias Scan | HW_Run_Infineon_Stack2_BiasScan_008 | 200k | 29.01.2014 12:15 | 29.01.2014 12:45 | Good |
HV at 240V; I at app. 7.5µA 3GeV, Single mode
|
91
|
Wed Jan 29 21:59:51 2014 |
Wolfgang Treberspurg | Infineon | Single mode Run Stack 2 Bias Scan | HW_Run_Infineon_Stack2_BiasScan_011 | 200k | 29.01.2014 13:45 | 29.01.2014 14:20 | Good |
HV at 270V; I at app. 7.6µA 3GeV, Single mode
|
92
|
Wed Jan 29 22:01:08 2014 |
Wolfgang Treberspurg | Infineon | Single mode Run Stack 2 Bias Scan | HW_Run_Infineon_Stack2_BiasScan_012 | 200k | 29.01.2014 14:25 | 29.01.2014 15:26 | Good |
HV at 280V; I at app. 8µA 3GeV, Single mode
|
93
|
Wed Jan 29 22:02:04 2014 |
Wolfgang Treberspurg | Infineon | Single mode Run Stack 2 Bias Scan | HW_Run_Infineon_Stack2_BiasScan_013 | 200k | 29.01.2014 15:26 | 29.01.2014 17:00 | Good |
HV at 290V; I at app. 8µA 3GeV, Single mode
|
94
|
Wed Jan 29 22:03:15 2014 |
Wolfgang Treberspurg | Infineon | Single mode Run Stack 2 Bias Scan | HW_Run_Infineon_Stack2_BiasScan_014 | 200k | 29.01.2014 18:15 | 29.01.2014 18:45 | Good |
HV at 260V; I at app. 7.5µA 3GeV, Single mode
|
95
|
Wed Jan 29 22:06:12 2014 |
Wolfgang Treberspurg | Infineon | Single mode Run Stack 2 Bias Scan | HW_Run_Infineon_Stack2_BiasScan_015 | 200k | 29.01.2014 19:15 | 29.01.2014 19:45 | Good |
HV at 300V; I at app. 7.5µA 3GeV, Single mode
|
97
|
Wed Jan 29 22:36:35 2014 |
Wolfgang Treberspurg | Infineon | Single mode Run Stack 2 Bias Scan | HW_Run_Infineon_Stack2_pos1_001 | 200k | 29.01.2014 22:15 | 29.01.2014 22:35 | Good |
HV at 300V; I at app. 7.5µA 3GeV, Single mode
Position changed to -3.910970 -17.800610
|
98
|
Wed Jan 29 22:40:09 2014 |
Wolfgang Treberspurg | Infineon | Single mode Run Stack 2 Bias Scan | HW_Run_Infineon_Stack2_pos2_002 | 200k | 29.01.2014 22:40 | 29.01.2014 23:15 | Good |
HV at 300V; I at app. 7.5µA 3GeV, Single mode
Position changed to --8.91097 -22.80061
|
19
|
Tue Jan 7 08:36:29 2014 |
Thomas Bergauer | Infineon | run | run014 | 20k | 07.01.2014 08:34:06 | 07.01.2014 09:05:47 | Good |
HV=290V I=9.55uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255
6Gev/c,
bad strip region hardly hit |
20
|
Tue Jan 7 09:12:24 2014 |
Thomas Bergauer | Belle SVD | run | run015 | 20k | 07.01.2014 09:10:52 | 07.01.2014 09:15:39 | Good |
HV=290V I=9.55uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255
energy switched back to 3Gev/c |
42
|
Wed Jan 8 14:10:07 2014 |
Thomas Bergauer | AIDA | run | run035 | 211681 | 08.01.2014 14:01:25 | 08.01.2014 17:03:55 | Unknown |
HV=100V I=4.2uA
position adapted to center beam
accidentally hit reset button on PC which ended this run abruptly...
5 GeV beam |
18
|
Tue Jan 7 02:18:26 2014 |
Markus Friedl | Infineon | run | run013 | 215k | 07.01.2014 02:14:50 | 07.01.2014 08:31:25 | Crap |
HV=150V I=7.90uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255
3 GeV beam momentum
close to end: switched to 6GeV
bias voltage accidentally left at 150V instead of initially planned 290V |
77
|
Sat Jan 25 21:14:46 2014 |
Wolfgang Treberspurg | Infineon | Mulit 6 mode Run Stack 2 | HW_Run_Infineon_Stack2_Multi_002 | 230k | 25.01.2014 19:00 | 25.01.2014 21:15 | Good |
HV 300V, I 10µA
Beam Energy 4GeV
Latency changed to 93 |
26
|
Tue Jan 7 13:20:48 2014 |
Markus Friedl | Infineon | run | run020 | 300k | 07.01.2014 13:18:52 | 07.01.2014 14:35:49 | Good |
HV=300V I=8.5uA
position adapted to center beam better (+10mm horizontal)
narrow trigger width (~5ns)
multi6 with same settings as run019 (htr+3)
Beam energy = 3 GeV |
64
|
Sun Jan 12 10:36:37 2014 |
Markus Friedl | AIDA | run | run055 | 310913 | 12.01.2014 10:34:44 | 12.01.2014 15:42:47 | Good |
HV=100V I=3.6uA
position = 23 / -35 mm relative to before
5GeV beam, 6 samples
narrow timing (trigger width)
|
43
|
Wed Jan 8 17:20:40 2014 |
Markus Friedl | AIDA | run | run036 | 320k | 08.01.2014 17:18:51 | 08.01.2014 22:14:58 | Unknown |
HV=100V I=4.3uA
centered position
5GeV beam
narrow timing (trigger width), but 6 samples
|
76
|
Sat Jan 25 18:46:32 2014 |
Wolfgang Treberspurg | Infineon | Mulit 6 mode Run Stack 2 | HW_Run_Infineon_Stack2_Multi_001 | 340k | 25.01.2014 16:30 | 25.01.2014 18:40 | Unknown |
HV 300V, I 10µA
Beam Energy changed during the run between 2GeV - 5GeV - 4GeV
Latency perhaps not optimal set (has been 95) but exchanged trigger cable seems to require 93 |