Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-rd50-desy-Oct2024 testbeam-RD50-DESY-Apr2024 testbeam-RD50-DESY-Jul2023 testbeam-RD50-CERN-Oct2022 testbeam-DESY-Oct2017 testbeam-DESY-April2017 testbeam-SPS2015 testbeam-SPS2014 testbeam-DESY14 testbeam-SPS12 testbeam-SPS11 testbeam-SPS10 testbeam-SPS09 testbeam-SPS08 LP-TPC
  Belle II and AIDA/Infineon Testbeam at DESY in Jan2014, Page 4 of 5  Not logged in ELOG logo
New entries since:Thu Jan 1 01:00:00 1970
ID Date Author Project Subject Run Number Eventsdown StartTime EndTime Data Text Attachments
  97   Wed Jan 29 22:36:35 2014 Wolfgang TreberspurgInfineonSingle mode Run Stack 2 Bias ScanHW_Run_Infineon_Stack2_pos1_001200k29.01.2014 22:1529.01.2014 22:35GoodHV at 300V; I at app. 7.5µA 3GeV,
Single mode
Position changed to -3.910970 -17.800610
  
  98   Wed Jan 29 22:40:09 2014 Wolfgang TreberspurgInfineonSingle mode Run Stack 2 Bias ScanHW_Run_Infineon_Stack2_pos2_002200k29.01.2014 22:4029.01.2014 23:15GoodHV at 300V; I at app. 7.5µA 3GeV,
Single mode
Position changed to --8.91097 -22.80061
  
  15   Tue Jan 7 00:36:03 2014 Markus FriedlInfineonrunrun012190k07.01.2014 00:33:5807.01.2014 02:12:32 GoodHV=150V  I=8.0uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255
  
  82   Wed Jan 29 12:04:53 2014 Wolfgang TreberspurgInfineonSingle mode Run Stack 2 Bias ScanHW_Run_Infineon_Stack2_BiasScan_002140k28.01.2014 16:5028.01.2014 17:20GoodHV at 100V; I at app. 8.5µA 3GeV,
Single mode
 
  
  79   Sun Jan 26 19:14:07 2014 Wolfgang TreberspurgInfineonSingle mode Run Stack 2HW_Run_Infineon_Stack2_003140 k26.01.2014 18:1026.01.2014 19:15GoodHV at 300V; I at app. 10µA 5GeV,
Single mode
 
  
  89   Wed Jan 29 21:56:58 2014 Wolfgang TreberspurgInfineonSingle mode Run Stack 2 Bias ScanHW_Run_Infineon_Stack2_BiasScan_009110k29.01.2014 12:5029.01.2014 13:15GoodHV at 250V; I at app. 7.5µA 3GeV,
Single mode
 
  
  24   Tue Jan 7 11:50:34 2014 Markus FriedlInfineonscanrun018x10k07.01.2014 11:xx:xx07.01.2014 11:xx:xxGoodDelay scan with single sample
Several runs
  
  22   Tue Jan 7 09:33:16 2014 Thomas Bergauer runrun017100k07.01.2014 09:31:4507.01.2014 09:52:58GoodHV=300V  I=9.08uA
position
adapted to center beam better (+10mm horizonal)
DESY
table z=-346 x=-255 
  
  47   Thu Jan 9 11:04:34 2014 Markus FriedlAIDArunrun039100k09.01.2014 11:02:3609.01.2014 12:28:41GoodHV=10V  I=2.1uA
centered position, HV scan
5GeV beam, 6 samples
  
  48   Thu Jan 9 12:31:29 2014 Markus FriedlAIDArunrun040100k09.01.2014 12:30:3209.01.2014 13:55:47GoodHV=20V  I=2.9uA
centered position, HV scan
5GeV beam, 6 samples
  
  49   Thu Jan 9 14:07:31 2014 Markus FriedlAIDArunrun041100k09.01.2014 14:06:3209.01.2014 15:33:13GoodHV=30V  I=3.3uA
centered position, HV scan
5GeV beam, 6 samples
  
  51   Thu Jan 9 16:36:30 2014 Markus FriedlAIDArunrun042100k09.01.2014 16:35:4309.01.2014 18:02:17GoodHV=40V  I=3.4uA
centered position, HV scan
5GeV beam, 6 samples
  
  52   Thu Jan 9 18:09:40 2014 Markus FriedlAIDArunrun044100k09.01.2014 18:08:1909.01.2014 19:35:21GoodHV=50V  I=3.6uA
centered position, HV scan
5GeV beam, 6 samples
  
  53   Thu Jan 9 19:37:33 2014 Markus FriedlAIDArunrun045100k09.01.2014 19:36:2109.01.2014 21:01:31 GoodHV=60V  I=3.8uA
centered position, HV scan
5GeV beam, 6 samples
  
  54   Thu Jan 9 21:41:20 2014 Markus FriedlAIDArunrun046100k09.01.2014 21:40:2909.01.2014 23:07:16GoodHV=70V  I=3.8uA
centered position, HV scan
5GeV beam, 6 samples
  
  55   Thu Jan 9 23:27:27 2014 Markus FriedlAIDArunrun047100k09.01.2014 23:26:3510.01.2014 00:52:56GoodHV=80V  I=3.8uA
centered position, HV scan
5GeV beam, 6 samples
  
  57   Fri Jan 10 08:21:46 2014 Markus FriedlAIDArunrun049100k10.01.2014 08:20:49 10.01.2014 09:49:46GoodHV=100V  I=4.2uA
centered position, HV scan
5GeV beam, 6 samples
  
  58   Fri Jan 10 09:54:11 2014 Markus FriedlAIDArunrun050100k10.01.2014 09:53:1310.01.2014 11:21:12GoodHV=110V  I=4.1uA
centered position, HV scan
5GeV beam, 6 samples
  
  60   Fri Jan 10 11:26:54 2014 Markus FriedlAIDArunrun051100k10.01.2014 11:26:0810.01.2014 12:53:12GoodHV=120V  I=4.6uA
centered position, HV scan
5GeV beam, 6 samples
  
  61   Fri Jan 10 13:04:49 2014 Markus FriedlAIDArunrun052100k10.01.2014 13:04:0510.01.2014 14:30:18GoodHV=130V  I=4.6uA
centered position, HV scan
5GeV beam, 6 samples
  