Home
CMS Production
Clean room
MedAustron
HEPHY
testbeams
old
testbeam-rd50-desy-Oct2024
testbeam-RD50-DESY-Apr2024
testbeam-RD50-DESY-Jul2023
testbeam-RD50-CERN-Oct2022
testbeam-DESY-Oct2017
testbeam-DESY-April2017
testbeam-SPS2015
testbeam-SPS2014
testbeam-DESY14
testbeam-SPS12
testbeam-SPS11
testbeam-SPS10
testbeam-SPS09
testbeam-SPS08
LP-TPC
Belle II and AIDA/Infineon Testbeam at DESY in Jan2014, Page 2 of 5
Not logged in
Find
|
Login
|
Help
New entries since:
Thu Jan 1 01:00:00 1970
Full
| Summary |
Threaded
-- All entries --
Last day
Last 3 Days
Last week
Last month
Last 3 Months
Last 6 Months
Last Year
-- Project --
common
Belle SVD
Infineon
AIDA
-- Data --
Unknown
Good
Crap
97 Entries
Goto page
Previous
1
, 2,
3
,
4
,
5
Next
All
ID
Date
Author
Project
Subject
Run Number
Events
StartTime
EndTime
Data
Text
26
Tue Jan 7 13:20:48 2014
Markus Friedl
Infineon
run
run020
300k
07.01.2014 13:18:52
07.01.2014 14:35:49
Good
HV=300V I=8.5uA
position adapted to center beam better
(+10mm horizontal)
77
Sat Jan 25 21:14:46 2014
Wolfgang Treberspurg
Infineon
Mulit 6 mode Run Stack 2
HW_Run_Infineon_Stack2_Multi_002
230k
25.01.2014 19:00
25.01.2014 21:15
Good
HV 300V, I 10µA
Beam Energy 4GeV
Latency changed to 93
18
Tue Jan 7 02:18:26 2014
Markus Friedl
Infineon
run
run013
215k
07.01.2014 02:14:50
07.01.2014 08:31:25
Crap
HV=150V I=7.90uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255
42
Wed Jan 8 14:10:07 2014
Thomas Bergauer
AIDA
run
run035
211681
08.01.2014 14:01:25
08.01.2014 17:03:55
Unknown
HV=100V I=4.2uA
position adapted to center beam
accidentally
hit reset button on PC which ended this run
19
Tue Jan 7 08:36:29 2014
Thomas Bergauer
Infineon
run
run014
20k
07.01.2014 08:34:06
07.01.2014 09:05:47
Good
HV=290V I=9.55uA
position
centered horizontally (+5mm)
DESY
table z=-346 x=-255
20
Tue Jan 7 09:12:24 2014
Thomas Bergauer
Belle SVD
run
run015
20k
07.01.2014 09:10:52
07.01.2014 09:15:39
Good
HV=290V I=9.55uA
position centered horizontally
(+5mm)
DESY table z=-346 x=-255
energy
3
Mon Jan 6 16:33:13 2014
Markus Friedl
Infineon
run
run001
200k
06.01.2014 16:28:58
06.01.2014 17:10:56
Good
HV=300V I=11.1uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255
4
Mon Jan 6 17:17:47 2014
Markus Friedl
Infineon
run
run002
200k
06.01.2014 17:14:39
06.01.2014 18:00:34
Good
HV=100V I=8.5uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255
5
Mon Jan 6 18:06:16 2014
Markus Friedl
Infineon
run
run003
200k
06.01.2014 18:04:14
06.01.2014 18:44:15
Good
HV=200V I=9.3uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255
6
Mon Jan 6 18:49:00 2014
Markus Friedl
Infineon
run
run004
200k
06.01.2014 18:47:38
06.01.2014 19:27:33
Good
HV=250V I=9.5uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255
8
Mon Jan 6 19:31:44 2014
Markus Friedl
AIDA
run
run005
200k
06.01.2014 19:29:52
06.01.2014 20:09:59
Good
HV=230V I=9.9uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255
9
Mon Jan 6 20:14:21 2014
Markus Friedl
Infineon
run
run006
200k
06.01.2014 20:12:20
06.01.2014 20:54:34
Good
HV=240V I=9.4uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255
10
Mon Jan 6 20:57:38 2014
Markus Friedl
Infineon
run
run007
200k
06.01.2014 20:56:08
06.01.2014 21:36:54
Good
HV=220V I=9.1uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255
11
Mon Jan 6 21:40:29 2014
Markus Friedl
Infineon
run
run008
200k
06.01.2014 21:38:46
06.01.2014 22:20:13
Good
HV=210V I=9.0uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255
12
Mon Jan 6 22:23:39 2014
Markus Friedl
Infineon
run
run009
200k
06.01.2014 22:22:10
06.01.2014 23:03:23
Good
HV=260V I=9.3uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255
13
Mon Jan 6 23:06:51 2014
Markus Friedl
Infineon
run
run010
200k
06.01.2014 23:03:23
06.01.2014 23:47:02
Good
HV=270V I=9.6uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255
14
Mon Jan 6 23:50:59 2014
Markus Friedl
Infineon
run
run011
200k
06.01.2014 23:49:09
07.01.2014 00:30:38
Good
HV=280V I=9.6uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255
27
Tue Jan 7 14:47:38 2014
Markus Friedl
Infineon
run
run021
200k
07.01.2014 14:46:08
07.01.2014 15:13:23
Good
HV=100V I=7.2uA
position adapted to center beam better
(+10mm horizontal)
29
Tue Jan 7 15:16:11 2014
Markus Friedl
Infineon
run
run022
200k
07.01.2014 15:15:09
07.01.2014 15:42:17
Good
HV=150V I=7.3uA
position adapted to center beam better
(+10mm horizontal)
30
Tue Jan 7 15:54:22 2014
Markus Friedl
Infineon
run
run023
200k
07.01.2014 15:53:06
07.01.2014 16:25:26
Good
HV=200V I=8.0uA
position adapted to center beam better