Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-RD50-DESY-Apr2024 testbeam-RD50-DESY-Jul2023 testbeam-RD50-CERN-Oct2022 testbeam-DESY-Oct2017 testbeam-DESY-April2017 testbeam-SPS2015 testbeam-SPS2014 testbeam-DESY14 testbeam-SPS12 testbeam-SPS11 testbeam-SPS10 testbeam-SPS09 testbeam-SPS08 LP-TPC
  Belle II and AIDA/Infineon Testbeam at DESY in Jan2014, Page 3 of 5  Not logged in ELOG logo
ID Date Author Project Subjectdown Run Number Events StartTime EndTime Data Text Attachments
  52   Thu Jan 9 18:09:40 2014 Markus FriedlAIDArunrun044100k09.01.2014 18:08:1909.01.2014 19:35:21GoodHV=50V  I=3.6uA
centered position, HV scan
5GeV beam, 6 samples
  
  53   Thu Jan 9 19:37:33 2014 Markus FriedlAIDArunrun045100k09.01.2014 19:36:2109.01.2014 21:01:31 GoodHV=60V  I=3.8uA
centered position, HV scan
5GeV beam, 6 samples
  
  54   Thu Jan 9 21:41:20 2014 Markus FriedlAIDArunrun046100k09.01.2014 21:40:2909.01.2014 23:07:16GoodHV=70V  I=3.8uA
centered position, HV scan
5GeV beam, 6 samples
  
  55   Thu Jan 9 23:27:27 2014 Markus FriedlAIDArunrun047100k09.01.2014 23:26:3510.01.2014 00:52:56GoodHV=80V  I=3.8uA
centered position, HV scan
5GeV beam, 6 samples
  
  56   Fri Jan 10 00:58:46 2014 Markus FriedlAIDArunrun048500k10.01.2014 00:57:4810.01.2014 08:17:57GoodHV=90V  I=3.9uA
centered position, HV scan
5GeV beam, 6 samples
  
  57   Fri Jan 10 08:21:46 2014 Markus FriedlAIDArunrun049100k10.01.2014 08:20:49 10.01.2014 09:49:46GoodHV=100V  I=4.2uA
centered position, HV scan
5GeV beam, 6 samples
  
  58   Fri Jan 10 09:54:11 2014 Markus FriedlAIDArunrun050100k10.01.2014 09:53:1310.01.2014 11:21:12GoodHV=110V  I=4.1uA
centered position, HV scan
5GeV beam, 6 samples
  
  60   Fri Jan 10 11:26:54 2014 Markus FriedlAIDArunrun051100k10.01.2014 11:26:0810.01.2014 12:53:12GoodHV=120V  I=4.6uA
centered position, HV scan
5GeV beam, 6 samples
  
  61   Fri Jan 10 13:04:49 2014 Markus FriedlAIDArunrun052100k10.01.2014 13:04:0510.01.2014 14:30:18GoodHV=130V  I=4.6uA
centered position, HV scan
5GeV beam, 6 samples
  
  62   Sat Jan 11 20:56:29 2014 Markus FriedlAIDArunrun053100k11.01.2014 20:55:2911.01.2014 22:25:43GoodHV=140V  I=7.1uA
centered position, HV scan
5GeV beam, 6 samples
  
  63   Sat Jan 11 22:32:19 2014 Markus FriedlAIDArunrun054800k11.01.2014 22:30:4412.01.2014 10:13:10GoodHV=150V  I=5.3uA
centered position, HV scan
5GeV beam, 6 samples
  
  64   Sun Jan 12 10:36:37 2014 Markus FriedlAIDArunrun05531091312.01.2014 10:34:4412.01.2014 15:42:47GoodHV=100V  I=3.6uA
position = 23 / -35 mm relative to
before
  
  65   Sun Jan 12 18:04:18 2014 Markus FriedlAIDArunrun056510k12.01.2014 17:59:5713.01.2014 01:47:50GoodHV=100V  I=3.7uA
position = -25 / 0 mm relative to
initial
  
  66   Mon Jan 13 01:58:14 2014 Markus FriedlAIDArunrun057900k13.01.2014 01:56:2613.01.2014 10:48:22GoodHV=100V  I=3.7uA
position = 0 / -30 mm relative to
initial (but again centered)
  
  50   Thu Jan 9 14:47:21 2014 Thomas Bergauercommonposition of DESY Table    UnknownBEAM mode:

    height (z): -346 (initially:
-357)
    horizontal (x): -255 

OFF
  
  41   Wed Jan 8 12:40:30 2014 Thomas BergauerAIDAintcal AIDA Stackcal03483.8k08.01.2014 12:32:2208.01.2014 13:01:30Unknown HV=100V  I=4.5uA
position adapted to center beam
 
  
  46   Thu Jan 9 11:02:14 2014 Markus FriedlAIDAinfo    UnknownCreated bad strip masks for the AIDA config
files
  
  1   Sat Jan 4 16:30:46 2014 Markus FriedlInfineoncalcal0018380004.01.2014 16:16:5104.01.2014 16:25:46GoodHV=300V  I=9.3uA  (total)   
  2   Sun Jan 5 15:08:09 2014 Markus FriedlAIDAcalcal0028380005.01.2014 15:01:3205.01.2014 15:30:36GoodHV=100V  I=6uA   
  45   Thu Jan 9 10:10:31 2014 Markus FriedlAIDAcalcal0388380009.01.2014 10:09:2709.01.2014 10:38:23GoodHV=100V  I=4.2uA
centered position
5GeV beam, single sample
  
ELOG V3.1.5-fc6679b