Fri Jan 10 09:54:11 2014, Markus Friedl, AIDA, run, run050, 100k, 10.01.2014 09:53:13, 10.01.2014 11:21:12, Good
|
HV=110V I=4.1uA
centered position, HV scan
5GeV beam, 6 samples
narrow timing (trigger width)
|
Fri Jan 10 08:21:46 2014, Markus Friedl, AIDA, run, run049, 100k, 10.01.2014 08:20:49 , 10.01.2014 09:49:46, Good
|
HV=100V I=4.2uA
centered position, HV scan
5GeV beam, 6 samples
narrow timing (trigger width)
|
Fri Jan 10 00:58:46 2014, Markus Friedl, AIDA, run, run048, 500k, 10.01.2014 00:57:48, 10.01.2014 08:17:57, Good
|
HV=90V I=3.9uA
centered position, HV scan
5GeV beam, 6 samples
narrow timing (trigger width)
|
Thu Jan 9 23:27:27 2014, Markus Friedl, AIDA, run, run047, 100k, 09.01.2014 23:26:35, 10.01.2014 00:52:56, Good
|
HV=80V I=3.8uA
centered position, HV scan
5GeV beam, 6 samples
narrow timing (trigger width)
|
Thu Jan 9 21:41:20 2014, Markus Friedl, AIDA, run, run046, 100k, 09.01.2014 21:40:29, 09.01.2014 23:07:16, Good
|
HV=70V I=3.8uA
centered position, HV scan
5GeV beam, 6 samples
narrow timing (trigger width)
|
Thu Jan 9 19:37:33 2014, Markus Friedl, AIDA, run, run045, 100k, 09.01.2014 19:36:21, 09.01.2014 21:01:31 , Good
|
HV=60V I=3.8uA
centered position, HV scan
5GeV beam, 6 samples
narrow timing (trigger width)
|
Thu Jan 9 18:09:40 2014, Markus Friedl, AIDA, run, run044, 100k, 09.01.2014 18:08:19, 09.01.2014 19:35:21, Good
|
HV=50V I=3.6uA
centered position, HV scan
5GeV beam, 6 samples
narrow timing (trigger width)
MOVED TIMING by 1 clock (now signal is centered again) |
Thu Jan 9 16:36:30 2014, Markus Friedl, AIDA, run, run042, 100k, 09.01.2014 16:35:43, 09.01.2014 18:02:17, Good
|
HV=40V I=3.4uA
centered position, HV scan
5GeV beam, 6 samples
narrow timing (trigger width)
|
Thu Jan 9 14:47:21 2014, Thomas Bergauer, common, position of DESY Table, , , , , Unknown
|
BEAM mode:
- height (z): -346 (initially: -357)
- horizontal (x): -255
OFF BEAM mode (Parkposition):
- height (z): +37
- horizontal (x): -255
|
Thu Jan 9 14:07:31 2014, Markus Friedl, AIDA, run, run041, 100k, 09.01.2014 14:06:32, 09.01.2014 15:33:13, Good
|
HV=30V I=3.3uA
centered position, HV scan
5GeV beam, 6 samples
narrow timing (trigger width)
|
Thu Jan 9 12:31:29 2014, Markus Friedl, AIDA, run, run040, 100k, 09.01.2014 12:30:32, 09.01.2014 13:55:47, Good
|
HV=20V I=2.9uA
centered position, HV scan
5GeV beam, 6 samples
narrow timing (trigger width)
|
Thu Jan 9 11:04:34 2014, Markus Friedl, AIDA, run, run039, 100k, 09.01.2014 11:02:36, 09.01.2014 12:28:41, Good
|
HV=10V I=2.1uA
centered position, HV scan
5GeV beam, 6 samples
narrow timing (trigger width)
|
Thu Jan 9 11:02:14 2014, Markus Friedl, AIDA, info, , , , , Unknown
|
Created bad strip masks for the AIDA config files |
Thu Jan 9 10:10:31 2014, Markus Friedl, AIDA, cal, cal038, 83800, 09.01.2014 10:09:27, 09.01.2014 10:38:23, Good
|
HV=100V I=4.2uA
centered position
5GeV beam, single sample
narrow timing (trigger width) |
Wed Jan 8 22:19:11 2014, Markus Friedl, AIDA, run, run037, 1.2M, 08.01.2014 22:18:30, 09.01.2014 10:08:14, Good
|
HV=100V I=4.4uA
centered position
5GeV beam, single sample
narrow timing (trigger width)
|
Wed Jan 8 17:20:40 2014, Markus Friedl, AIDA, run, run036, 320k, 08.01.2014 17:18:51, 08.01.2014 22:14:58, Unknown
|
HV=100V I=4.3uA
centered position
5GeV beam
narrow timing (trigger width), but 6 samples
|
Wed Jan 8 14:10:07 2014, Thomas Bergauer, AIDA, run, run035, 211681, 08.01.2014 14:01:25, 08.01.2014 17:03:55, Unknown
|
HV=100V I=4.2uA
position adapted to center beam
accidentally hit reset button on PC which ended this run abruptly...
5 GeV beam |
Wed Jan 8 12:40:30 2014, Thomas Bergauer, AIDA, intcal AIDA Stack, cal034, 83.8k, 08.01.2014 12:32:22, 08.01.2014 13:01:30, Unknown
|
HV=100V I=4.5uA
position adapted to center beam
|
Tue Jan 7 21:34:41 2014, Markus Friedl, Infineon, run, run033, 4.117.024 (4M), 07.01.2014 21:33:12, 08.01.2014 08:52:37, Good
|
HV=300V I=8.3uA
position adapted to center beam better (+10mm horizontal)
narrow trigger width (~5ns)
single trigger
Beam energy = 3 GeV
beam gone at 8:00 morning because of scheduled beam development. last few 100 events only noise. |
Tue Jan 7 21:02:58 2014, Markus Friedl, Infineon, run, run032, 200k, 07.01.2014 21:01:42, 07.01.2014 21:29:03, Good
|
HV=290V I=8.3uA
position adapted to center beam better (+10mm horizontal)
narrow trigger width (~5ns)
single trigger
Beam energy = 3 GeV |
|