Thu Jan 9 18:09:40 2014, Markus Friedl, AIDA, run, run044, 100k, 09.01.2014 18:08:19, 09.01.2014 19:35:21, Good
|
HV=50V I=3.6uA
centered position, HV scan
5GeV beam, 6 samples |
Thu Jan 9 16:36:30 2014, Markus Friedl, AIDA, run, run042, 100k, 09.01.2014 16:35:43, 09.01.2014 18:02:17, Good
|
HV=40V I=3.4uA
centered position, HV scan
5GeV beam, 6 samples |
Thu Jan 9 14:07:31 2014, Markus Friedl, AIDA, run, run041, 100k, 09.01.2014 14:06:32, 09.01.2014 15:33:13, Good
|
HV=30V I=3.3uA
centered position, HV scan
5GeV beam, 6 samples |
Thu Jan 9 12:31:29 2014, Markus Friedl, AIDA, run, run040, 100k, 09.01.2014 12:30:32, 09.01.2014 13:55:47, Good
|
HV=20V I=2.9uA
centered position, HV scan
5GeV beam, 6 samples |
Thu Jan 9 11:04:34 2014, Markus Friedl, AIDA, run, run039, 100k, 09.01.2014 11:02:36, 09.01.2014 12:28:41, Good
|
HV=10V I=2.1uA
centered position, HV scan
5GeV beam, 6 samples |
Thu Jan 9 10:10:31 2014, Markus Friedl, AIDA, cal, cal038, 83800, 09.01.2014 10:09:27, 09.01.2014 10:38:23, Good
|
HV=100V I=4.2uA
centered position
5GeV beam, single sample |
Wed Jan 8 22:19:11 2014, Markus Friedl, AIDA, run, run037, 1.2M, 08.01.2014 22:18:30, 09.01.2014 10:08:14, Good
|
HV=100V I=4.4uA
centered position
5GeV beam, single sample |
Wed Jan 8 17:20:40 2014, Markus Friedl, AIDA, run, run036, 320k, 08.01.2014 17:18:51, 08.01.2014 22:14:58, Unknown
|
HV=100V I=4.3uA
centered position
5GeV beam |
Wed Jan 8 14:10:07 2014, Thomas Bergauer, AIDA, run, run035, 211681, 08.01.2014 14:01:25, 08.01.2014 17:03:55, Unknown
|
HV=100V I=4.2uA
position adapted to center beam
accidentally hit reset button on PC which ended this run abruptly...
|
Wed Jan 8 12:40:30 2014, Thomas Bergauer, AIDA, intcal AIDA Stack, cal034, 83.8k, 08.01.2014 12:32:22, 08.01.2014 13:01:30, Unknown
|
HV=100V I=4.5uA
position adapted to center beam
|
Tue Jan 7 21:34:41 2014, Markus Friedl, Infineon, run, run033, 4.117.024 (4M), 07.01.2014 21:33:12, 08.01.2014 08:52:37, Good
|
HV=300V I=8.3uA
position adapted to center beam better (+10mm horizontal)
narrow trigger width (~5ns) |
Tue Jan 7 11:50:34 2014, Markus Friedl, Infineon, scan, run018x, 10k, 07.01.2014 11:xx:xx, 07.01.2014 11:xx:xx, Good
|
Delay scan with single sample
Several runs |
Tue Jan 7 21:02:58 2014, Markus Friedl, Infineon, run, run032, 200k, 07.01.2014 21:01:42, 07.01.2014 21:29:03, Good
|
HV=290V I=8.3uA
position adapted to center beam better (+10mm horizontal)
narrow trigger width (~5ns) |
Tue Jan 7 20:26:50 2014, Markus Friedl, Infineon, run, run031, 200k, 07.01.2014 20:25:32, 07.01.2014 20:58:47, Good
|
HV=280V I=8.4uA
position adapted to center beam better (+10mm horizontal)
narrow trigger width (~5ns) |
Tue Jan 7 19:44:45 2014, Markus Friedl, Infineon, run, run030, 200k, 07.01.2014 19:43:35, 07.01.2014 20:11:03, Good
|
HV=270V I=8.6uA
position adapted to center beam better (+10mm horizontal)
narrow trigger width (~5ns) |
Tue Jan 7 19:12:07 2014, Markus Friedl, Infineon, run, run029, 200k, 07.01.2014 19:11:05, 07.01.2014 19:38:00, Good
|
HV=260V I=8.7uA
position adapted to center beam better (+10mm horizontal)
narrow trigger width (~5ns) |
Tue Jan 7 18:41:55 2014, Markus Friedl, Infineon, run, run028, 200k, 07.01.2014 18:40:40, 07.01.2014 19:07:32, Good
|
HV=250V I=8.3uA
position adapted to center beam better (+10mm horizontal)
narrow trigger width (~5ns) |
Tue Jan 7 18:11:52 2014, Markus Friedl, Infineon, run, run027, 200k, 07.01.2014 18:10:45, 07.01.2014 18:37:42, Good
|
HV=240V I=8.2uA
position adapted to center beam better (+10mm horizontal)
narrow trigger width (~5ns) |
Tue Jan 7 17:39:20 2014, Markus Friedl, Infineon, run, run026, 200k, 07.01.2014 17:38:01, 07.01.2014 18:05:11, Good
|
HV=230V I=8.2uA
position adapted to center beam better (+10mm horizontal)
narrow trigger width (~5ns) |
Tue Jan 7 17:09:56 2014, Markus Friedl, Infineon, run, run025, 200k, 07.01.2014 17:08:54, 07.01.2014 17:36:12, Good
|
HV=220V I=8.1uA
position adapted to center beam better (+10mm horizontal)
narrow trigger width (~5ns) |
|