Tue Jan 7 13:20:48 2014, Markus Friedl, Infineon, run, run020, 300k, 07.01.2014 13:18:52, 07.01.2014 14:35:49, Good
|
HV=300V I=8.5uA
position adapted to center beam better (+10mm horizontal)
narrow trigger width (~5ns) |
Sat Jan 25 21:14:46 2014, Wolfgang Treberspurg, Infineon, Mulit 6 mode Run Stack 2, HW_Run_Infineon_Stack2_Multi_002, 230k, 25.01.2014 19:00, 25.01.2014 21:15, Good
|
HV 300V, I 10µA
Beam Energy 4GeV
Latency changed to 93 |
Tue Jan 7 02:18:26 2014, Markus Friedl, Infineon, run, run013, 215k, 07.01.2014 02:14:50, 07.01.2014 08:31:25, Crap
|
HV=150V I=7.90uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255 |
Wed Jan 8 14:10:07 2014, Thomas Bergauer, AIDA, run, run035, 211681, 08.01.2014 14:01:25, 08.01.2014 17:03:55, Unknown
|
HV=100V I=4.2uA
position adapted to center beam
accidentally hit reset button on PC which ended this run abruptly...
|
Tue Jan 7 08:36:29 2014, Thomas Bergauer, Infineon, run, run014, 20k, 07.01.2014 08:34:06, 07.01.2014 09:05:47, Good
|
HV=290V I=9.55uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255
6Gev/c,
bad strip region hardly hit |
Tue Jan 7 09:12:24 2014, Thomas Bergauer, Belle SVD, run, run015, 20k, 07.01.2014 09:10:52, 07.01.2014 09:15:39, Good
|
HV=290V I=9.55uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255
energy switched back to 3Gev/c |
Mon Jan 6 16:33:13 2014, Markus Friedl, Infineon, run, run001, 200k, 06.01.2014 16:28:58, 06.01.2014 17:10:56, Good
|
HV=300V I=11.1uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255 |
Mon Jan 6 17:17:47 2014, Markus Friedl, Infineon, run, run002, 200k, 06.01.2014 17:14:39, 06.01.2014 18:00:34, Good
|
HV=100V I=8.5uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255 |
Mon Jan 6 18:06:16 2014, Markus Friedl, Infineon, run, run003, 200k, 06.01.2014 18:04:14, 06.01.2014 18:44:15, Good
|
HV=200V I=9.3uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255 |
Mon Jan 6 18:49:00 2014, Markus Friedl, Infineon, run, run004, 200k, 06.01.2014 18:47:38, 06.01.2014 19:27:33, Good
|
HV=250V I=9.5uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255 |
Mon Jan 6 19:31:44 2014, Markus Friedl, AIDA, run, run005, 200k, 06.01.2014 19:29:52, 06.01.2014 20:09:59, Good
|
HV=230V I=9.9uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255 |
Mon Jan 6 20:14:21 2014, Markus Friedl, Infineon, run, run006, 200k, 06.01.2014 20:12:20, 06.01.2014 20:54:34, Good
|
HV=240V I=9.4uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255 |
Mon Jan 6 20:57:38 2014, Markus Friedl, Infineon, run, run007, 200k, 06.01.2014 20:56:08, 06.01.2014 21:36:54, Good
|
HV=220V I=9.1uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255 |
Mon Jan 6 21:40:29 2014, Markus Friedl, Infineon, run, run008, 200k, 06.01.2014 21:38:46, 06.01.2014 22:20:13, Good
|
HV=210V I=9.0uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255 |
Mon Jan 6 22:23:39 2014, Markus Friedl, Infineon, run, run009, 200k, 06.01.2014 22:22:10, 06.01.2014 23:03:23, Good
|
HV=260V I=9.3uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255 |
Mon Jan 6 23:06:51 2014, Markus Friedl, Infineon, run, run010, 200k, 06.01.2014 23:03:23, 06.01.2014 23:47:02 , Good
|
HV=270V I=9.6uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255 |
Mon Jan 6 23:50:59 2014, Markus Friedl, Infineon, run, run011, 200k, 06.01.2014 23:49:09, 07.01.2014 00:30:38 , Good
|
HV=280V I=9.6uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255 |
Tue Jan 7 14:47:38 2014, Markus Friedl, Infineon, run, run021, 200k, 07.01.2014 14:46:08, 07.01.2014 15:13:23, Good
|
HV=100V I=7.2uA
position adapted to center beam better (+10mm horizontal)
narrow trigger width (~5ns) |
Tue Jan 7 15:16:11 2014, Markus Friedl, Infineon, run, run022, 200k, 07.01.2014 15:15:09, 07.01.2014 15:42:17, Good
|
HV=150V I=7.3uA
position adapted to center beam better (+10mm horizontal)
narrow trigger width (~5ns) |
Tue Jan 7 15:54:22 2014, Markus Friedl, Infineon, run, run023, 200k, 07.01.2014 15:53:06, 07.01.2014 16:25:26, Good
|
HV=200V I=8.0uA
position adapted to center beam better (+10mm horizontal)
narrow trigger width (~5ns) |
|