Entry  Wed Jan 29 22:01:08 2014, Wolfgang Treberspurg, Infineon, Single mode Run Stack 2 Bias Scan, HW_Run_Infineon_Stack2_BiasScan_012, 200k, 29.01.2014 14:25, 29.01.2014 15:26, Good 
HV at 280V; I at app. 8µA 3GeV, Single mode
 
Entry  Wed Jan 29 22:02:04 2014, Wolfgang Treberspurg, Infineon, Single mode Run Stack 2 Bias Scan, HW_Run_Infineon_Stack2_BiasScan_013, 200k, 29.01.2014 15:26, 29.01.2014 17:00, Good 
HV at 290V; I at app. 8µA 3GeV, Single mode
 
Entry  Wed Jan 29 22:03:15 2014, Wolfgang Treberspurg, Infineon, Single mode Run Stack 2 Bias Scan, HW_Run_Infineon_Stack2_BiasScan_014, 200k, 29.01.2014 18:15, 29.01.2014 18:45, Good 
HV at 260V; I at app. 7.5µA 3GeV, Single mode
 
Entry  Wed Jan 29 22:06:12 2014, Wolfgang Treberspurg, Infineon, Single mode Run Stack 2 Bias Scan, HW_Run_Infineon_Stack2_BiasScan_015, 200k, 29.01.2014 19:15, 29.01.2014 19:45, Good 
HV at 300V; I at app. 7.5µA 3GeV, Single mode
 
Entry  Wed Jan 29 22:08:48 2014, Wolfgang Treberspurg, Infineon, Single mode Run Stack 2 Bias Scan, , , 29.01.2014 22:00, 29.01.2014 22:00, Good 
All Infineon Stack 2 runs have been taken at table position: 1.089030, -12.800610
 
Entry  Wed Jan 29 22:36:35 2014, Wolfgang Treberspurg, Infineon, Single mode Run Stack 2 Bias Scan, HW_Run_Infineon_Stack2_pos1_001, 200k, 29.01.2014 22:15, 29.01.2014 22:35, Good 
HV at 300V; I at app. 7.5µA 3GeV, Single mode
Position changed to -3.910970 -17.800610
 
Entry  Wed Jan 29 22:40:09 2014, Wolfgang Treberspurg, Infineon, Single mode Run Stack 2 Bias Scan, HW_Run_Infineon_Stack2_pos2_002, 200k, 29.01.2014 22:40, 29.01.2014 23:15, Good 
HV at 300V; I at app. 7.5µA 3GeV, Single mode
Position changed to --8.91097 -22.80061
 
Entry  Mon Jan 6 19:10:36 2014, Thomas Bergauer, common, Beam Momentum 3GeV/c, run001 to run012, , , , Unknown IMG_1517.jpgIMG_1516.jpg
We have set the beam momentum to 3 GeV 
Entry  Tue Jan 7 02:17:14 2014, Thomas Bergauer, , beam momentum 6GeV/c, run013, , , , Unknown 
 
Entry  Tue Jan 7 08:36:29 2014, Thomas Bergauer, Infineon, run, run014, 20k, 07.01.2014 08:34:06, 07.01.2014 09:05:47, Good 
HV=290V  I=9.55uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255 
6Gev/c,
bad strip region hardly hit
Entry  Tue Jan 7 09:12:24 2014, Thomas Bergauer, Belle SVD, run, run015, 20k, 07.01.2014 09:10:52, 07.01.2014 09:15:39, Good 
 HV=290V  I=9.55uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255
 
energy switched back to 3Gev/c
Entry  Tue Jan 7 09:22:09 2014, Thomas Bergauer, , run, run016, 50k, 07.01.2014 09:19:10, 07.01.2014 09:30:03, Good 
HV=290V  I=9.00uA
position move back to original position (0mm/0mm) (not hitting the right APVs anymore)
DESY
table z=-346 x=-255 
Entry  Tue Jan 7 09:33:16 2014, Thomas Bergauer, , run, run017, 100k, 07.01.2014 09:31:45, 07.01.2014 09:52:58, Good 
HV=300V  I=9.08uA
position adapted to center beam better (+10mm horizonal)
DESY table z=-346 x=-255 
3Gev/c
Entry  Tue Jan 7 09:33:51 2014, Thomas Bergauer, common, beam momentum back to 3Gev/c, run014 and later ones, , , , Unknown 
 
Entry  Tue Jan 7 14:51:45 2014, Thomas Bergauer, Belle SVD, TLU control, , , , , Unknown 
1. ssh bastion
2. ssh belle-control
3. ssh telescope-admin@tb-aconite
Entry  Wed Jan 8 12:40:30 2014, Thomas Bergauer, AIDA, intcal AIDA Stack, cal034, 83.8k, 08.01.2014 12:32:22, 08.01.2014 13:01:30, Unknown 
 HV=100V  I=4.5uA
position adapted to center beam
 
Entry  Wed Jan 8 14:10:07 2014, Thomas Bergauer, AIDA, run, run035, 211681, 08.01.2014 14:01:25, 08.01.2014 17:03:55, Unknown 
 HV=100V  I=4.2uA
position adapted to center beam
 
accidentally hit reset button on PC which ended this run abruptly...
 
Entry  Thu Jan 9 14:47:21 2014, Thomas Bergauer, common, position of DESY Table, , , , , Unknown 
BEAM mode:

    height (z): -346 (initially: -357)
    horizontal (x): -255 

OFF BEAM mode (Parkposition):

    height (z): +37
    horizontal (x): -255 

 
Entry  Sat Jan 4 16:30:46 2014, Markus Friedl, Infineon, cal, cal001, 83800, 04.01.2014 16:16:51, 04.01.2014 16:25:46, Good 
HV=300V  I=9.3uA  (total)
Entry  Sun Jan 5 15:08:09 2014, Markus Friedl, AIDA, cal, cal002, 83800, 05.01.2014 15:01:32, 05.01.2014 15:30:36, Good 
HV=100V  I=6uA