Home
CMS Production
Clean room
MedAustron
HEPHY
testbeams
old
testbeam-rd50-desy-Oct2024
testbeam-RD50-DESY-Apr2024
testbeam-RD50-DESY-Jul2023
testbeam-RD50-CERN-Oct2022
testbeam-DESY-Oct2017
testbeam-DESY-April2017
testbeam-SPS2015
testbeam-SPS2014
testbeam-DESY14
testbeam-SPS12
testbeam-SPS11
testbeam-SPS10
testbeam-SPS09
testbeam-SPS08
LP-TPC
Belle II and AIDA/Infineon Testbeam at DESY in Jan2014, Page 2 of 5
Not logged in
Find
|
Login
|
Help
New entries since:
Thu Jan 1 01:00:00 1970
Full
| Summary |
Threaded
-- All entries --
Last day
Last 3 Days
Last week
Last month
Last 3 Months
Last 6 Months
Last Year
-- Project --
common
Belle SVD
Infineon
AIDA
-- Data --
Unknown
Good
Crap
97 Entries
Goto page
Previous
1
, 2,
3
,
4
,
5
Next
All
ID
Date
Author
Project
Subject
Run Number
Events
StartTime
EndTime
Data
Text
42
Wed Jan 8 14:10:07 2014
Thomas Bergauer
AIDA
run
run035
211681
08.01.2014 14:01:25
08.01.2014 17:03:55
Unknown
HV=100V I=4.2uA
position adapted to center beam
accidentally
hit reset button on PC which ended this run
40
Tue Jan 7 21:34:41 2014
Markus Friedl
Infineon
run
run033
4.117.024 (4M)
07.01.2014 21:33:12
08.01.2014 08:52:37
Good
HV=300V I=8.3uA
position adapted to center beam better
(+10mm horizontal)
39
Tue Jan 7 21:02:58 2014
Markus Friedl
Infineon
run
run032
200k
07.01.2014 21:01:42
07.01.2014 21:29:03
Good
HV=290V I=8.3uA
position adapted to center beam better
(+10mm horizontal)
38
Tue Jan 7 20:26:50 2014
Markus Friedl
Infineon
run
run031
200k
07.01.2014 20:25:32
07.01.2014 20:58:47
Good
HV=280V I=8.4uA
position adapted to center beam better
(+10mm horizontal)
37
Tue Jan 7 19:44:45 2014
Markus Friedl
Infineon
run
run030
200k
07.01.2014 19:43:35
07.01.2014 20:11:03
Good
HV=270V I=8.6uA
position adapted to center beam better
(+10mm horizontal)
36
Tue Jan 7 19:12:07 2014
Markus Friedl
Infineon
run
run029
200k
07.01.2014 19:11:05
07.01.2014 19:38:00
Good
HV=260V I=8.7uA
position adapted to center beam better
(+10mm horizontal)
35
Tue Jan 7 18:41:55 2014
Markus Friedl
Infineon
run
run028
200k
07.01.2014 18:40:40
07.01.2014 19:07:32
Good
HV=250V I=8.3uA
position adapted to center beam better
(+10mm horizontal)
34
Tue Jan 7 18:11:52 2014
Markus Friedl
Infineon
run
run027
200k
07.01.2014 18:10:45
07.01.2014 18:37:42
Good
HV=240V I=8.2uA
position adapted to center beam better
(+10mm horizontal)
33
Tue Jan 7 17:39:20 2014
Markus Friedl
Infineon
run
run026
200k
07.01.2014 17:38:01
07.01.2014 18:05:11
Good
HV=230V I=8.2uA
position adapted to center beam better
(+10mm horizontal)
32
Tue Jan 7 17:09:56 2014
Markus Friedl
Infineon
run
run025
200k
07.01.2014 17:08:54
07.01.2014 17:36:12
Good
HV=220V I=8.1uA
position adapted to center beam better
(+10mm horizontal)
31
Tue Jan 7 16:36:49 2014
Markus Friedl
Infineon
run
run024
200k
07.01.2014 16:35:44
07.01.2014 17:03:10
Good
HV=210V I=8.1uA
position adapted to center beam better
(+10mm horizontal)
30
Tue Jan 7 15:54:22 2014
Markus Friedl
Infineon
run
run023
200k
07.01.2014 15:53:06
07.01.2014 16:25:26
Good
HV=200V I=8.0uA
position adapted to center beam better
(+10mm horizontal)
29
Tue Jan 7 15:16:11 2014
Markus Friedl
Infineon
run
run022
200k
07.01.2014 15:15:09
07.01.2014 15:42:17
Good
HV=150V I=7.3uA
position adapted to center beam better
(+10mm horizontal)
27
Tue Jan 7 14:47:38 2014
Markus Friedl
Infineon
run
run021
200k
07.01.2014 14:46:08
07.01.2014 15:13:23
Good
HV=100V I=7.2uA
position adapted to center beam better
(+10mm horizontal)
26
Tue Jan 7 13:20:48 2014
Markus Friedl
Infineon
run
run020
300k
07.01.2014 13:18:52
07.01.2014 14:35:49
Good
HV=300V I=8.5uA
position adapted to center beam better
(+10mm horizontal)
25
Tue Jan 7 11:52:27 2014
Markus Friedl
Infineon
run
run019
650k
07.01.2014 11:47:24
07.01.2014 13:15:21
Good
HV=300V I=9.2uA
position adapted to center beam better
(+10mm horizontal)
24
Tue Jan 7 11:50:34 2014
Markus Friedl
Infineon
scan
run018x
10k
07.01.2014 11:xx:xx
07.01.2014 11:xx:xx
Good
Delay scan with single sample
Several runs
22
Tue Jan 7 09:33:16 2014
Thomas Bergauer
run
run017
100k
07.01.2014 09:31:45
07.01.2014 09:52:58
Good
HV=300V I=9.08uA
position
adapted to center beam better (+10mm horizonal)
DESY
table z=-346 x=-255
21
Tue Jan 7 09:22:09 2014
Thomas Bergauer
run
run016
50k
07.01.2014 09:19:10
07.01.2014 09:30:03
Good
HV=290V I=9.00uA
position
move back to original position (0mm/0mm)
(not hitting the right APVs anymore)
DESY
20
Tue Jan 7 09:12:24 2014
Thomas Bergauer
Belle SVD
run
run015
20k
07.01.2014 09:10:52
07.01.2014 09:15:39
Good
HV=290V I=9.55uA
position centered horizontally
(+5mm)
DESY table z=-346 x=-255