ID |
Date |
Author |
Project |
Subject |
Run Number |
Events |
StartTime |
EndTime |
Data |
87
|
Wed Jan 29 21:55:09 2014 |
Wolfgang Treberspurg | Infineon | Single mode Run Stack 2 Bias Scan | HW_Run_Infineon_Stack2_BiasScan_007 | 200k | 29.01.2014 11:50 | 29.01.2014 12:15 | Good |
HV at 230V; I at app. 8µA 3GeV, Single mode
|
88
|
Wed Jan 29 21:56:15 2014 |
Wolfgang Treberspurg | Infineon | Single mode Run Stack 2 Bias Scan | HW_Run_Infineon_Stack2_BiasScan_008 | 200k | 29.01.2014 12:15 | 29.01.2014 12:45 | Good |
HV at 240V; I at app. 7.5µA 3GeV, Single mode
|
89
|
Wed Jan 29 21:56:58 2014 |
Wolfgang Treberspurg | Infineon | Single mode Run Stack 2 Bias Scan | HW_Run_Infineon_Stack2_BiasScan_009 | 110k | 29.01.2014 12:50 | 29.01.2014 13:15 | Good |
HV at 250V; I at app. 7.5µA 3GeV, Single mode
|
90
|
Wed Jan 29 21:57:55 2014 |
Wolfgang Treberspurg | Infineon | Single mode Run Stack 2 Bias Scan | HW_Run_Infineon_Stack2_BiasScan_010 | 100k | 29.01.2014 13:20 | 29.01.2014 13:35 | Good |
HV at 260V; I at app. 7.6µA 3GeV, Single mode
|
91
|
Wed Jan 29 21:59:51 2014 |
Wolfgang Treberspurg | Infineon | Single mode Run Stack 2 Bias Scan | HW_Run_Infineon_Stack2_BiasScan_011 | 200k | 29.01.2014 13:45 | 29.01.2014 14:20 | Good |
HV at 270V; I at app. 7.6µA 3GeV, Single mode
|
92
|
Wed Jan 29 22:01:08 2014 |
Wolfgang Treberspurg | Infineon | Single mode Run Stack 2 Bias Scan | HW_Run_Infineon_Stack2_BiasScan_012 | 200k | 29.01.2014 14:25 | 29.01.2014 15:26 | Good |
HV at 280V; I at app. 8µA 3GeV, Single mode
|
93
|
Wed Jan 29 22:02:04 2014 |
Wolfgang Treberspurg | Infineon | Single mode Run Stack 2 Bias Scan | HW_Run_Infineon_Stack2_BiasScan_013 | 200k | 29.01.2014 15:26 | 29.01.2014 17:00 | Good |
HV at 290V; I at app. 8µA 3GeV, Single mode
|
94
|
Wed Jan 29 22:03:15 2014 |
Wolfgang Treberspurg | Infineon | Single mode Run Stack 2 Bias Scan | HW_Run_Infineon_Stack2_BiasScan_014 | 200k | 29.01.2014 18:15 | 29.01.2014 18:45 | Good |
HV at 260V; I at app. 7.5µA 3GeV, Single mode
|
95
|
Wed Jan 29 22:06:12 2014 |
Wolfgang Treberspurg | Infineon | Single mode Run Stack 2 Bias Scan | HW_Run_Infineon_Stack2_BiasScan_015 | 200k | 29.01.2014 19:15 | 29.01.2014 19:45 | Good |
HV at 300V; I at app. 7.5µA 3GeV, Single mode
|
96
|
Wed Jan 29 22:08:48 2014 |
Wolfgang Treberspurg | Infineon | Single mode Run Stack 2 Bias Scan | | | 29.01.2014 22:00 | 29.01.2014 22:00 | Good |
All Infineon Stack 2 runs have been taken at table position: 1.089030, -12.800610
|
97
|
Wed Jan 29 22:36:35 2014 |
Wolfgang Treberspurg | Infineon | Single mode Run Stack 2 Bias Scan | HW_Run_Infineon_Stack2_pos1_001 | 200k | 29.01.2014 22:15 | 29.01.2014 22:35 | Good |
HV at 300V; I at app. 7.5µA 3GeV, Single mode
Position changed to -3.910970 -17.800610
|
98
|
Wed Jan 29 22:40:09 2014 |
Wolfgang Treberspurg | Infineon | Single mode Run Stack 2 Bias Scan | HW_Run_Infineon_Stack2_pos2_002 | 200k | 29.01.2014 22:40 | 29.01.2014 23:15 | Good |
HV at 300V; I at app. 7.5µA 3GeV, Single mode
Position changed to --8.91097 -22.80061
|
7
|
Mon Jan 6 19:10:36 2014 |
Thomas Bergauer | common | Beam Momentum 3GeV/c | run001 to run012 | | | | Unknown |
We have set the beam momentum to 3 GeV |
Attachment 1: IMG_1517.jpg
|
|
Attachment 2: IMG_1516.jpg
|
|
23
|
Tue Jan 7 09:33:51 2014 |
Thomas Bergauer | common | beam momentum back to 3Gev/c | run014 and later ones | | | | Unknown |
|
50
|
Thu Jan 9 14:47:21 2014 |
Thomas Bergauer | common | position of DESY Table | | | | | Unknown |
BEAM mode:
- height (z): -346 (initially: -357)
- horizontal (x): -255
OFF BEAM mode (Parkposition):
- height (z): +37
- horizontal (x): -255
|
67
|
Mon Jan 13 12:02:40 2014 |
Markus Friedl | common | Kontakt | | | | | Unknown |
Richard Thalmeier Tel. 4801
Hao Yin |
68
|
Sun Jan 19 18:01:46 2014 |
Christian Irmler | common | AIDA setup operated with TuxDAQ | | | | | Unknown |
New SIS driver version sis1100-2.13-3 installed on DAQPC.
To install the driver call as root:
cd /lib/modules/2.6.18-371.3.1.el5/extra
/sbin/modprobe sis1100
Check if /dev/sis* are created.
Managed to run the AIDA setup with old TuxDAQ version from T. Obermayer.
Will now try to install a newer version, which also supports ADC delay scan and internal calibration. |