  Alibava testbeam at DESY in Oct. 2017 (Dominic, Peter), Page 7 of 7  Not logged in ELOG logo
ID Date Author DUT Subject Run Number Events XYPosition Coolingdown Data
  16   Wed Oct 18 13:36:50 2017 Peter PaulitschIFX_CenterBiasrun000109109110000122.9, 25.75, -3.3°NoGood
run settings
Parameter Value
Alibava filename  run000109.dat
Telescope filename  run000109.raw
Pedestal filename pedestal_17102017
Bias voltage -100 V
Dark current -160 nA
Sensor temperature 24.6 °C
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y 122.9, 25.75
Region of interest bias line
Trigger frequency  200 Hz
Meas. time 15 min
Beam energy 5.6 GeV
Cooling no
Alibava efficiency 53.4%

 

  17   Wed Oct 18 13:38:47 2017 Peter PaulitschIFX_CenterBiasrun0001121123010000122.9, 24.25, -3.3°NoGood
run settings
Parameter Value
Alibava filename  run000112.dat
Telescope filename  run000112.raw
Pedestal filename pedestal_17102017
Bias voltage -100 V
Dark current -160 nA
Sensor temperature 24.6 °C
Latency 140 [a.u.]
Alibava triggers 3010000
Telescope triggers 3000000
Data synced yes
Table position x/y 122.9, 24.25
Region of interest bias line
Trigger frequency  157 Hz
Meas. time 320 min
Beam energy 5.6 GeV
Cooling no
Alibava efficiency 53.8%

 

  75   Tue Oct 24 18:02:47 2017 Peter PaulitschHPK_200run000264264110000NoGood
Parameter Value
Alibava filename  run000264.dat
Telescope filename  run000264.raw
Pedestal filename HEPHY_pedestal_HPK_CB_2.ped
Bias voltage -200 V
Dark current  
Sensor temperature -7
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y  
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling no
Alibava efficiency  
  76   Tue Oct 24 18:04:09 2017 Peter PaulitschHPK_200run000266266110000NoGood
Parameter Value
Alibava filename  run000266.dat
Telescope filename  run000266.raw
Pedestal filename HEPHY_pedestal_HPK_CB_2.ped
Bias voltage -200 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y  
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling no
Alibava efficiency  
  77   Tue Oct 24 18:08:06 2017 Peter PaulitschHPK_200run000271271110000NoGood
Parameter Value
Alibava filename  run000271.dat
Telescope filename  run000271.raw
Pedestal filename HEPHY_pedestal_HPK_CB_2.ped
Bias voltage -200 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y  
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling no
Alibava efficiency  
  78   Tue Oct 24 18:08:38 2017 Peter PaulitschHPK_200run000273273110000NoGood
Parameter Value
Alibava filename  run000273.dat
Telescope filename  run000273.raw
Pedestal filename HEPHY_pedestal_HPK_CB_2.ped
Bias voltage -200 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y  
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling no
Alibava efficiency  
  79   Tue Oct 24 18:08:57 2017 Peter PaulitschHPK_200run0002752751010000NoGood
Parameter Value
Alibava filename  run000275.dat
Telescope filename  run000275.raw
Pedestal filename HEPHY_pedestal_HPK_CB_2.ped
Bias voltage -200 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y  
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling no
Alibava efficiency  
  80   Tue Oct 24 18:09:24 2017 Peter PaulitschHPK_200run0002772771010000NoGood
Parameter Value
Alibava filename  run000277.dat
Telescope filename  run000277.raw
Pedestal filename HEPHY_pedestal_HPK_CB_2.ped
Bias voltage -200 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y  
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling no
Alibava efficiency  
  81   Tue Oct 24 18:09:43 2017 Peter PaulitschHPK_200run000279279110000NoGood
Parameter Value
Alibava filename  run000279.dat
Telescope filename  run000279.raw
Pedestal filename HEPHY_pedestal_HPK_CB_2.ped
Bias voltage -200 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y  
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling no
Alibava efficiency  
  82   Tue Oct 24 18:10:14 2017 Peter PaulitschHPK_200run000281281110000NoGood
Parameter Value
Alibava filename  run000281.dat
Telescope filename  run000281.raw
Pedestal filename HEPHY_pedestal_HPK_CB_2.ped
Bias voltage -200 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y  
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling no
Alibava efficiency  
  83   Tue Oct 24 18:10:39 2017 Peter PaulitschHPK_200run0002832831010000NoGood
Parameter Value
Alibava filename  run000283.dat
Telescope filename  run000283.raw
Pedestal filename HEPHY_pedestal_HPK_CB_2.ped
Bias voltage -200 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y  
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling no
Alibava efficiency  
  84   Tue Oct 24 18:11:13 2017 Peter PaulitschHPK_200run0002852851010000NoGood
Parameter Value
Alibava filename  run000285.dat
Telescope filename  run000285.raw
Pedestal filename HEPHY_pedestal_HPK_CB_2.ped
Bias voltage -200 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y  
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling no
Alibava efficiency  
  85   Tue Oct 24 18:11:43 2017 Peter PaulitschHPK_200run0002872871010000NoGood
Parameter Value
Alibava filename  run000287.dat
Telescope filename  run000287.raw
Pedestal filename HEPHY_pedestal_HPK_CB_2.ped
Bias voltage -600 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y  
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling no
Alibava efficiency  