  Alibava testbeam at DESY in Oct. 2017 (Dominic, Peter), Page 6 of 7  Not logged in ELOG logo
ID Date Author DUT Subject Run Number Events XYPosition Cooling Data
  33   Fri Oct 20 14:58:56 2017 Peter PaulitschIFX_200_3e14run00018418410000075.93, 65.30, -110.55°YesGood
run settings
Parameter Value
Alibava filename  run000184.dat
Telescope filename  run000184.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -600 V
Dark current 40 uA
Sensor temperature -6
Latency 140 [a.u.]
Alibava triggers 100000
Telescope triggers 100000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency 33.5%

 

  32   Fri Oct 20 14:57:30 2017 Peter PaulitschIFX_200_3e14run00018218210000075.93, 65.30, -115.55°YesGood
run settings
Parameter Value
Alibava filename  run000182.dat
Telescope filename  run000182.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -600 V
Dark current 40 uA
Sensor temperature -6
Latency 140 [a.u.]
Alibava triggers 100000
Telescope triggers 100000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency 33.6%

 

  31   Fri Oct 20 14:54:11 2017 Peter PaulitschIFX_200_3e14run00018118170000075.93, 65.30, -70.55°YesGood
run settings
Parameter Value
Alibava filename  run000181.dat
Telescope filename  run000181.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -600 V
Dark current 40 uA
Sensor temperature -6
Latency 140 [a.u.]
Alibava triggers 700000
Telescope triggers 700000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency 33.4%

 

  30   Fri Oct 20 14:52:36 2017 Peter PaulitschIFX_200_3e14run00018018040000075.93, 65.30, -70.55°YesGood
run settings
Parameter Value
Alibava filename  run000180.dat
Telescope filename  run000180.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -600 V
Dark current 40 uA
Sensor temperature -6
Latency 140 [a.u.]
Alibava triggers 400000
Telescope triggers 400000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency 33.1%

 

  29   Fri Oct 20 14:50:03 2017 Peter PaulitschIFX_200_3e14run00017917920000075.93, 65.30, -70.55°YesGood
run settings
Parameter Value
Alibava filename  run000179.dat
Telescope filename  run000179.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -700 V
Dark current 40 uA
Sensor temperature -6
Latency 140 [a.u.]
Alibava triggers 200000
Telescope triggers 200000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency 33.2%

 

  28   Fri Oct 20 14:35:48 2017 Peter PaulitschIFX_200_3e14run000177177101000075.93, 65.30, -70.55°YesGood
run settings
Parameter Value
Alibava filename  run000177.dat
Telescope filename  run000177.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -400 V
Dark current 40 uA
Sensor temperature -6
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency 33.8%

 

  27   Fri Oct 20 14:29:57 2017 Peter PaulitschIFX_200_3e14run00017317311000075.93, 65.30, -70.55°YesGood
run settings
Parameter Value
Alibava filename  run000173.dat
Telescope filename  run000173.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -600 V
Dark current 90 uA
Sensor temperature -6
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency 33.2%

 

  26   Fri Oct 20 14:26:59 2017 Peter PaulitschIFX_200_3e14run00016916911000075.93, 65.30, -70.55°YesGood
run settings
Parameter Value
Alibava filename  run000169.dat
Telescope filename  run000169.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -600 V
Dark current 90 uA
Sensor temperature -6
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency 33.5%

 

  25   Fri Oct 20 14:23:59 2017 Peter PaulitschIFX_200_3e14run00016616611000075.93, 65.30, -70.55°YesGood
run settings
Parameter Value
Alibava filename  run000166.dat
Telescope filename  run000166.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -600 V
Dark current 90 uA
Sensor temperature -6
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency 33.2%

 

  24   Fri Oct 20 14:16:03 2017 Peter PaulitschIFX_200_3e14run00016416411000075.93, 65.30, -70.55°YesGood
run settings
Parameter Value
Alibava filename  run000164.dat
Telescope filename  run000164.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -600 V
Dark current 90 uA
Sensor temperature -6
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 110000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency  250 Hz
Meas. time 12 min
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency 33.5%

 

  23   Fri Oct 20 14:14:15 2017 Peter PaulitschIFX_200_3e14run00016216211000075.93, 65.30, -70.55°YesGood
run settings
Parameter Value
Alibava filename  run000162.dat
Telescope filename  run000162.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -600 V
Dark current 90 uA
Sensor temperature -6
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency  250 Hz
Meas. time 12 min
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency 33.2%

 

  22   Fri Oct 20 14:12:20 2017 Peter PaulitschIFX_200_3e14run00012412411000075.93, 65.30, -72.55°YesGood
run settings
Parameter Value
Alibava filename  run000124.dat
Telescope filename  run000124.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -600 V
Dark current 39 uA
Sensor temperature -6
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency  210 Hz
Meas. time 15 min
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency 33.3%

 

  21   Fri Oct 20 14:11:03 2017 Peter PaulitschIFX_200_3e14run00012212211000075.93, 65.30, -72.55°YesGood
run settings
Parameter Value
Alibava filename  run000122.dat
Telescope filename  run000122.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -600 V
Dark current 39 uA
Sensor temperature -6
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency  210 Hz
Meas. time 15 min
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency 33.7%

 

  20   Fri Oct 20 14:09:11 2017 Peter PaulitschIFX_200_3e14run00012012011000075.93, 64.80, -72.55°YesGood
run settings
Parameter Value
Alibava filename  run000120.dat
Telescope filename  run000120.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -600 V
Dark current 39 uA
Sensor temperature -6
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y 75.93, 64.80
Region of interest bias line
Trigger frequency  210 Hz
Meas. time 15 min
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency 33.5%

 

  19   Fri Oct 20 14:05:39 2017 Peter PaulitschIFX_200_3e14run00011811811000075.93, 61.20, -72.55°YesGood
run settings
Parameter Value
Alibava filename  run000118.dat
Telescope filename  run000118.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -600 V
Dark current 39 uA
Sensor temperature -6
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y 75.93, 61.20
Region of interest bias line
Trigger frequency  210 Hz
Meas. time 15 min
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency 33.2%

 

  18   Fri Oct 20 12:15:47 2017 Peter PaulitschIFX_200_3e14run00011611611000075.93, 63.00, -72.55°YesGood
run settings
Parameter Value
Alibava filename  run000116.dat
Telescope filename  run000116.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -600 V
Dark current 39 uA
Sensor temperature -6
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y 75.93, 63.00
Region of interest bias line
Trigger frequency  210 Hz
Meas. time 15 min
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency 33.2%

 

  17   Wed Oct 18 13:38:47 2017 Peter PaulitschIFX_CenterBiasrun0001121123010000122.9, 24.25, -3.3°NoGood
run settings
Parameter Value
Alibava filename  run000112.dat
Telescope filename  run000112.raw
Pedestal filename pedestal_17102017
Bias voltage -100 V
Dark current -160 nA
Sensor temperature 24.6 °C
Latency 140 [a.u.]
Alibava triggers 3010000
Telescope triggers 3000000
Data synced yes
Table position x/y 122.9, 24.25
Region of interest bias line
Trigger frequency  157 Hz
Meas. time 320 min
Beam energy 5.6 GeV
Cooling no
Alibava efficiency 53.8%

 

  16   Wed Oct 18 13:36:50 2017 Peter PaulitschIFX_CenterBiasrun000109109110000122.9, 25.75, -3.3°NoGood
run settings
Parameter Value
Alibava filename  run000109.dat
Telescope filename  run000109.raw
Pedestal filename pedestal_17102017
Bias voltage -100 V
Dark current -160 nA
Sensor temperature 24.6 °C
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y 122.9, 25.75
Region of interest bias line
Trigger frequency  200 Hz
Meas. time 15 min
Beam energy 5.6 GeV
Cooling no
Alibava efficiency 53.4%

 

  15   Wed Oct 18 13:34:54 2017 Peter PaulitschIFX_CenterBiasrun000107107110000122.9, 23.5, -3.3°NoGood
run settings
Parameter Value
Alibava filename  run000107.dat
Telescope filename  run000107.raw
Pedestal filename pedestal_17102017
Bias voltage -100 V
Dark current -160 nA
Sensor temperature 24.6 °C
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y 122.9, 23.5
Region of interest bias line
Trigger frequency  200 Hz
Meas. time 15 min
Beam energy 5.6 GeV
Cooling no
Alibava efficiency 53.4%

 

  14   Wed Oct 18 13:33:05 2017 Peter PaulitschIFX_CenterBiasrun00010610660000122.9, 23.5, -3.3°NoGood
run settings
Parameter Value
Alibava filename  run000106.dat
Telescope filename  run000106.raw
Pedestal filename pedestal_17102017
Bias voltage -100 V
Dark current -160 nA
Sensor temperature 24.6 °C
Latency 140 [a.u.]
Alibava triggers 60000
Telescope triggers 50000
Data synced yes
Table position x/y 122.9, 23.5
Region of interest bias line
Trigger frequency  200 Hz
Meas. time 8 min
Beam energy 5.6 GeV
Cooling no
Alibava efficiency 53.4%

 