  Alibava testbeam at DESY in Oct. 2017 (Dominic, Peter), Page 3 of 7  Not logged in ELOG logo
Entry  Sat Oct 21 10:21:25 2017, Peter Paulitsch, HPK_3e14, run000236, 236, 400000, 75.93, 65.30, -70.55°, Yes, Good 
run settings
Parameter Value
Alibava filename  run000236.dat
Telescope filename  run000236.raw
Pedestal filename KIT_HPK_200_3e14.ped
Bias voltage -800 V
Dark current 40 uA
Sensor temperature -7
Latency 140 [a.u.]
Alibava triggers 410000
Telescope triggers 400000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency  200
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency 46.1%

 

Entry  Sat Oct 21 10:22:43 2017, Peter Paulitsch, HPK_3e14, run000237, 237, 3010000, 75.93, 65.30, -70.55°, Yes, Good 
run settings
Parameter Value
Alibava filename  run000237.dat
Telescope filename  run000237.raw
Pedestal filename KIT_HPK_200_3e14.ped
Bias voltage -600 V
Dark current 40 uA
Sensor temperature -7
Latency 140 [a.u.]
Alibava triggers 4010000
Telescope triggers 4000000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency  200
Meas. time night run
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency 46.1%

 

Entry  Mon Oct 23 09:24:23 2017, Dominic Bloech, HPK_3e14, run000240, 240, 1010000, 75.93, 65.30, -70.55°, Yes, Crap 
Parameter Value
Alibava filename  run000240.dat
Telescope filename  run000240.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -100 V
Dark current  
Sensor temperature -6
Latency 140 [a.u.]
Alibava triggers 3010000
Telescope triggers 3000000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency  200
Meas. time 80min
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency 29.7%
Entry  Mon Oct 23 12:07:01 2017, Peter Paulitsch, IFX_200_3e14, run000172, 169, crashed, 6000000, bad header, 75.93, 65.30, -70.55°, Yes, Good 
run settings
Parameter Value
Alibava filename  run000172.dat
Telescope filename  run000172.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -600 V
Dark current 90 uA
Sensor temperature -6
Latency 140 [a.u.]
Alibava triggers 6000000
Telescope triggers 6000000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency 33.8%

 

Entry  Mon Oct 23 12:10:15 2017, Peter Paulitsch, IFX_200_3e14, run000175, 175, 1010000, 75.93, 65.30, -70.55°, Yes, Good 
run settings
Parameter Value
Alibava filename  run000177.dat
Telescope filename  run000177.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -600 V
Dark current 40 uA
Sensor temperature -6
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency 33.1%

 

Entry  Mon Oct 23 12:19:57 2017, Peter Paulitsch, IFX_200_3e14, run000186, 188, 100000, 75.93, 65.30, -100.55°, Yes, Good 
run settings
Parameter Value
Alibava filename  run000186.dat
Telescope filename  run000186.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -600 V
Dark current 40 uA
Sensor temperature -6
Latency 140 [a.u.]
Alibava triggers 100000
Telescope triggers 100000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency 33.1%

 

Entry  Tue Oct 24 17:46:11 2017, Peter Paulitsch, HPK_3e14, run000244, 244, 110000, 75.93, 65.30, -100.55°, Yes, Good 
Parameter Value
Alibava filename  run000244.dat
Telescope filename  run000244.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -600 V
Dark current  
Sensor temperature -7
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency 46.1%
Entry  Tue Oct 24 17:50:04 2017, Peter Paulitsch, HPK_3e14, run000242, 242, 1010000, 75.93, 65.30, -70.55°, Yes, Good 
Parameter Value
Alibava filename  run000242.dat
Telescope filename  run000242.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -600 V
Dark current  
Sensor temperature -7
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency 29.7%
Entry  Tue Oct 24 17:51:18 2017, Peter Paulitsch, HPK_3e14, run000246, 246, 1010000, 75.93, 65.30, -100.55°, Yes, Good 
Parameter Value
Alibava filename  run000246.dat
Telescope filename  run000246.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -600 V
Dark current  
Sensor temperature -7
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency  
Entry  Tue Oct 24 17:53:19 2017, Peter Paulitsch, HPK_3e14, run000248, 248, 110000, 75.93, 65.30, -90.55°, Yes, Good 
Parameter Value
Alibava filename  run000248.dat
Telescope filename  run000248.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -600 V
Dark current  
Sensor temperature -7
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency  
Entry  Tue Oct 24 17:56:36 2017, Peter Paulitsch, HPK_3e14, run000249, 249, 1010000, 75.93, 65.30, -90.55°, Yes, Good 
Parameter Value
Alibava filename  run000249.dat
Telescope filename  run000249.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -600 V
Dark current  
Sensor temperature -7
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency  
Entry  Tue Oct 24 17:57:28 2017, Peter Paulitsch, HPK_3e14, run000251, 251, 110000, 75.93, 65.30, -80.55°, Yes, Good 
Parameter Value
Alibava filename  run000251.dat
Telescope filename  run000251.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -600 V
Dark current  
Sensor temperature -7
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency  
Entry  Tue Oct 24 17:58:09 2017, Peter Paulitsch, HPK_3e14, run000255, 255, 110000, 75.93, 65.30, -80.55°, Yes, Good 
Parameter Value
Alibava filename  run000255.dat
Telescope filename  run000255.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -600 V
Dark current  
Sensor temperature -7
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency  
Entry  Tue Oct 24 17:58:43 2017, Peter Paulitsch, HPK_3e14, run000257, 257, 1010000, 75.93, 65.30, -80.55°, Yes, Good 
Parameter Value
Alibava filename  run000257.dat
Telescope filename  run000257.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -600 V
Dark current  
Sensor temperature -7
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency  
Entry  Tue Oct 24 17:59:58 2017, Peter Paulitsch, HPK_3e14, run000259, 259, 110000, 75.93, 65.30, -70.55°, Yes, Good 
Parameter Value
Alibava filename  run000259.dat
Telescope filename  run000259.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -500 V
Dark current 37 uA
Sensor temperature -7
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency  
Entry  Tue Oct 24 18:01:13 2017, Peter Paulitsch, HPK_3e14, run000261, 261, 1010000, 75.93, 65.30, -70.55°, Yes, Good 
Parameter Value
Alibava filename  run000261.dat
Telescope filename  run000261.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -500 V
Dark current  
Sensor temperature -7
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency  
Entry  Tue Oct 24 18:02:07 2017, Peter Paulitsch, HPK_3e14, run000263, 263, 3010000, 75.93, 65.30, -70.55°, Yes, Good 
Parameter Value
Alibava filename  run000263.dat
Telescope filename  run000263.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -600 V
Dark current  
Sensor temperature -7
Latency 140 [a.u.]
Alibava triggers 3010000
Telescope triggers 3000000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency  
Entry  Tue Oct 24 18:12:25 2017, Peter Paulitsch, HPK_3e14, run000291, 291, 110000, 30°, Yes, Good 
Parameter Value
Alibava filename  run000291.dat
Telescope filename  run000291.raw
Pedestal filename KIT_pedestal_600V_22102017.ped
Bias voltage -600 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y  
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency  
Entry  Tue Oct 24 18:14:17 2017, Peter Paulitsch, HPK_3e14, run000293, 293, 110000, 30°, Yes, Good 
Parameter Value
Alibava filename  run000293.dat
Telescope filename  run000293.raw
Pedestal filename KIT_pedestal_600V_22102017.ped
Bias voltage -600 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y  
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency  
Entry  Tue Oct 24 18:15:48 2017, Peter Paulitsch, HPK_3e14, run000295, 295, 1010000, 30°, Yes, Good 
Parameter Value
Alibava filename  run000295.dat
Telescope filename  run000295.raw
Pedestal filename KIT_pedestal_600V_22102017.ped
Bias voltage -600 V
Dark current 50 uA
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y  
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency 44,5%