92
|
Mon Apr 17 08:14:24 2017 |
Axel Koenig | ALiBaVa (IFX) | run_016_Baby_75V.dat | 016 | 112000 | 102.5, 22.5, 240 | No | Unknown |
Remarks: Telescope run 593. Bias scan 75 V.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_016_Baby_75V.dat |
Telescope run |
593 |
Triggers |
112000 |
Alibava trigger eff. |
~60% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-75 |
Latency |
132 |
Table x |
102.5 mm |
Table z |
22.5 mm |
Tabe rot |
240 deg
|
|
93
|
Mon Apr 17 09:01:09 2017 |
Axel Koenig | ALiBaVa (IFX) | run_017_Baby_80V.dat | 017 | 112000 | 102.5, 22.5, 240 | No | Unknown |
Remarks: Telescope run 594. Bias scan 80 V.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_017_Baby_80V.dat |
Telescope run |
594 |
Triggers |
112000 |
Alibava trigger eff. |
~90% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-80 |
Latency |
132 |
Table x |
102.5 mm |
Table z |
22.5 mm |
Tabe rot |
240 deg
|
|
94
|
Mon Apr 17 09:04:02 2017 |
Axel Koenig | ALiBaVa (IFX) | run_006_Baby_100V.dat | 006 | k.a. | 102.5, 22.5, 230 | No | Unknown |
Remarks: Telescope run 570. Telescope chiller turned off (could be the root cause of runs crashing).
Forgot ro record data in elog.
Parameter |
Value |
Alibava run |
run_006_Baby_100V.dat |
Telescope run |
570 |
Triggers |
k.a. |
Alibava trigger eff. |
~93% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-100 |
Latency |
132 |
Table x |
102.5 mm |
Table z |
22.5 mm |
Tabe rot |
230 deg
|
|
95
|
Mon Apr 17 09:29:40 2017 |
Axel Koenig | ALiBaVa (IFX) | run_018_Baby_90V.dat | 018 | 112000 | 102.5, 22.5, 240 | No | Unknown |
Remarks: Telescope run 595. Bias scan 90 V.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_018_Baby_90V.dat |
Telescope run |
595 |
Triggers |
112000 |
Alibava trigger eff. |
~90% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-90 |
Latency |
132 |
Table x |
102.5 mm |
Table z |
22.5 mm |
Tabe rot |
240 deg
|
|
96
|
Mon Apr 17 10:05:57 2017 |
Axel Koenig | ALiBaVa (IFX) | run_019_Baby_110V.dat | 019 | 112000 | 102.5, 22.5, 240 | No | Unknown |
Remarks: Telescope run 596. Bias scan 110 V.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_019_Baby_110V.dat |
Telescope run |
596 |
Triggers |
112000 |
Alibava trigger eff. |
~90% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-110 |
Latency |
132 |
Table x |
102.5 mm |
Table z |
22.5 mm |
Tabe rot |
240 deg
|
|
97
|
Mon Apr 17 10:10:33 2017 |
Johannes Grossmann | MaPSA | HV_Scan | 387 | 0 | 0 | No | Unknown |
Changed HV from 80 V to 60 V
Not in condition data applied in the settings
10:08 17.4.2017 |
98
|
Mon Apr 17 10:14:15 2017 |
Axel Koenig | common | Run summary Baby | | | | No | Unknown |
Alibava run |
Telescope run |
File existence check |
Run type |
Triggers |
Remarks |
001 |
562 |
yes |
first run |
250000 |
none |
002 |
563 |
yes |
central position shifted by -1 cm vertically |
250000 |
none |
003 |
564 |
yes |
central position shifted by + 1cm |
250000 |
none |
004 |
565 |
yes |
central position angle +10 deg |
250000 |
none |
005 |
568 |
yes |
central position angle -10 deg |
250000 |
none |
006 |
570 |
yes |
unknown (maybe long run over night that crashed) |
? |
data may be corrupted |
007 |
579 |
yes |
bias scan -10V |
450000 |
run crashed data only valid up to 274915 |
008 |
583 |
yes |
bias scan -20V |
175000 |
none |
009 |
586 |
yes |
bias scan -30V |
135000 |
none |
010 |
587 |
yes |
bias scan -40V |
135000 |
none |
011 |
588 |
yes |
bias scan -50V |
135000 |
none |
012 |
589 |
yes |
bias scan -60V |
135000 |
none |
013 |
590 |
yes |
bias scan -65V |
112000 |
none |
014 |
591 |
yes |
bias scan -70V |
112000 |
none |
015 |
592 |
yes |
long run over night |
2500000 |
none |
016 |
593 |
yes |
bias scan -75V |
112000 |
none |
017 |
594 |
yes |
bias scan -80V |
112000 |
none |
018 |
595 |
yes |
bias scan -90V |
112000 |
none |
019 |
596 |
yes |
bias scan -110V |
112000 |
none |
020 |
597 |
yes |
bias scan -120V |
112000 |
none |
021 |
598 |
yes |
bias scan -130V |
112000 |
none |
022 |
599 |
yes |
bias scan -140V |
112000 |
none |
023 |
600 |
yes |
bias scan -150V |
112000 |
none |
Central beam position: x = 102 mm, y = 22.5 mm, rot = 240 deg
Current was stable for all runs i.e. 500 +- 10 nA at 100 V
Trigger efficiency ~ 90% for all runs (except bias scan).
Temperature in area 20+-1 deg.
Telescope chiller off for all runs. |
99
|
Mon Apr 17 10:36:22 2017 |
Axel Koenig | ALiBaVa (IFX) | run_020_Baby_120V.dat | 020 | 112000 | 102.5, 22.5, 240 | No | Unknown |
Remarks: Telescope run 597. Bias scan 120 V.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_020_Baby_120V.dat |
Telescope run |
597 |
Triggers |
112000 |
Alibava trigger eff. |
~90% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-120 |
Latency |
132 |
Table x |
102.5 mm |
Table z |
22.5 mm |
Tabe rot |
240 deg
|
|
100
|
Mon Apr 17 11:04:40 2017 |
Axel Koenig | ALiBaVa (IFX) | run_021_Baby_130V.dat | 021 | 112000 | 102.5, 22.5, 240 | No | Unknown |
Remarks: Telescope run 598. Bias scan 130 V.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_021_Baby_130V.dat |
Telescope run |
598 |
Triggers |
112000 |
Alibava trigger eff. |
~90% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-130 |
Latency |
132 |
Table x |
102.5 mm |
Table z |
22.5 mm |
Tabe rot |
240 deg
|
|
101
|
Mon Apr 17 11:34:55 2017 |
Axel Koenig | ALiBaVa (IFX) | run_022_Baby_140V.dat | 022 | 112000 | 102.5, 22.5, 240 | No | Unknown |
Remarks: Telescope run 599. Bias scan 140 V.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_022_Baby_140V.dat |
Telescope run |
599 |
Triggers |
112000 |
Alibava trigger eff. |
~90% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-140 |
Latency |
132 |
Table x |
102.5 mm |
Table z |
22.5 mm |
Tabe rot |
240 deg
|
|
104
|
Mon Apr 17 12:06:11 2017 |
Axel Koenig | ALiBaVa (IFX) | run_023_Baby_150V.dat | 023 | 112000 | 102.5, 22.5, 240 | No | Unknown |
Remarks: Telescope run 600. Bias scan 150 V.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_023_Baby_150V.dat |
Telescope run |
600 |
Triggers |
112000 |
Alibava trigger eff. |
~90% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-150 |
Latency |
132 |
Table x |
102.5 mm |
Table z |
22.5 mm |
Tabe rot |
240 deg
|
|
103
|
Mon Apr 17 12:26:33 2017 |
Johannes Grossmann | MaPSA | HV_Scan | 456 | 0 | 0 | No | Unknown |
Changed HV from 60 V to 120 V
12:24 17.4.2017 |
105
|
Mon Apr 17 13:30:01 2017 |
Axel Koenig | ALiBaVa (IFX) | run_001_HPK_CB_200V.dat | 001 | 450000 | 107, 0, 240 | No | Unknown |
Remarks: Telescope run 604. Bias scan 200 V. Only one chip.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_001_HPK_CB_200V.dat |
Telescope run |
604 |
Triggers |
450000 |
Alibava trigger eff. |
~64% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-200 |
Latency |
132 |
Table x |
107 mm |
Table z |
0 mm |
Tabe rot |
240 deg
|
|
106
|
Mon Apr 17 16:36:56 2017 |
Axel Koenig | ALiBaVa (IFX) | run_002_HPK_CB_200V.dat | 002 | 450000 | 107, 5.8, 240 | No | Unknown |
Remarks: Telescope run 605. Bias scan 200 V. Only one chip.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_002_HPK_CB_200V.dat |
Telescope run |
605 |
Triggers |
450000 |
Alibava trigger eff. |
~64% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-200 |
Latency |
132 |
Table x |
107 mm |
Table z |
5.8 mm |
Tabe rot |
240 deg
|
|
107
|
Mon Apr 17 17:02:34 2017 |
Axel Koenig | ALiBaVa (IFX) | run_003_HPK_CB_200V.dat | 003 | 250000 | 107, 2.6, 230 | No | Unknown |
Remarks: Telescope run 606. Angle scan.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_003_HPK_CB_200V.dat |
Telescope run |
606 |
Triggers |
250000 |
Alibava trigger eff. |
~62% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-200 |
Latency |
132 |
Table x |
107 mm |
Table z |
2.6 mm |
Tabe rot |
230 deg
|
|
108
|
Mon Apr 17 17:25:24 2017 |
Axel Koenig | common | Telescope geometry ALiBaVa | | | | No | Unknown |
The plane distances are measured at the center of the planes.
The distance of the DUT to the neighbouring planes is measured from the position of the sensor to the center of the planes.
|
Attachment 1: IMG_1522.JPG
|
|
Attachment 2: beam.pdf
|
Attachment 3: beam1.pdf
|
Attachment 4: beam2.pdf
|
109
|
Mon Apr 17 17:46:38 2017 |
Axel Koenig | ALiBaVa (IFX) | run_005_HPK_CB_50V.dat | 005 | 150000 | 107, 2.6, 240 | No | Unknown |
Remarks: Telescope run 609. Bias scan 50 V. Bias scan.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_005_HPK_CB_50V.dat |
Telescope run |
609 |
Triggers |
150000 |
Alibava trigger eff. |
~62% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-50 |
Latency |
132 |
Table x |
107 mm |
Table z |
2.6 mm |
Tabe rot |
240 deg
|
|
110
|
Mon Apr 17 17:55:55 2017 |
Johannes Grossmann | MaPSA | HV_Scan | 488 | 0 | 0 | No | Unknown |
Changed HV from 120 V to 90 V
17:53 17.4.2017 |
111
|
Mon Apr 17 19:19:14 2017 |
Axel Koenig | ALiBaVa (IFX) | run_006_HPK_CB_100V.dat | 006 | 150000 | 107, 2.6, 240 | No | Unknown |
Remarks: Telescope run 610. Bias scan 100 V. Bias scan.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_006_HPK_CB_100V.dat |
Telescope run |
610 |
Triggers |
150000 |
Alibava trigger eff. |
~62% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-100 |
Latency |
132 |
Table x |
107 mm |
Table z |
2.6 mm |
Tabe rot |
240 deg
|
|
113
|
Mon Apr 17 19:54:08 2017 |
Axel Koenig | ALiBaVa (IFX) | run_007_HPK_CB_150V.dat | 007 | 300000 | 107, 2.6, 240 | No | Unknown |
Remarks: Telescope run 611. Bias scan 150 V. Bias scan. Run crashed at 294000 triggers!
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_007_HPK_CB_150V.dat |
Telescope run |
611 |
Triggers |
300000 |
Alibava trigger eff. |
~62% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-150 |
Latency |
132 |
Table x |
107 mm |
Table z |
2.6 mm |
Tabe rot |
240 deg
|
|