Wed Apr 23 13:05:05 2008, Christian Irmler, SPS Testbeam June08, source, hybrid 01, time correlation between TDC and sensor measurement -> 3.1 ns RMS
|
|
Wed Apr 23 13:37:18 2008, Markus Friedl, SPS Testbeam June08, source, hybrid 01, analysis results of source test
|
Ignore the "KEK November 2007" title - that's a legacy and is already changed :-)
As of now, there is no distinction in 16 separate zones. However, the gaps between the the zones are clearly visible in the Hit Profile, as the edge strips |
Tue May 20 14:27:50 2008, Markus Friedl, BELLE Upgrade, source, micron, analysis results of source test 9x
|
*** NOTE: AFTER THIS MEASUREMENT WE REALIZED THAT BIASING WAS NOT DONE PROPERLY
HENCE THE RESULTS BELOW ARE NOT RELIABLE
|
Sun Jul 4 05:48:36 2010, Christian Irmler, BELLE Upgrade, source, Origami 6 - module 1, run002: first analysis results 7x
|
Run name: run002
Run type: 0 (Hardware (Normal Run)) |
Wed May 7 14:36:29 2014, Benedikt Würkner, Belle II, source, L3 module, No 1 of 6 room temperature measurements using Sr90 Source (multi6) 10x
|
Sr90 Radioactive Source
No cooling
Module position: -5:-20(top left) |
Wed May 7 15:04:32 2014, Benedikt Würkner, Belle II, source, L3 module, No 2 of 6 room temperature measurements using Sr90 Source (multi6) 10x
|
Sr90 Radioactive Source
No cooling
Module position: -32:-20(top center) |
Wed May 7 15:53:38 2014, Benedikt Würkner, Belle II, source, L3 module, No 3 of 6 room temperature measurements using Sr90 Source (multi6) 10x
|
Sr90 Radioactive Source
No cooling
Module position: -59:-20(top right) |
Wed May 7 16:43:37 2014, Benedikt Würkner, Belle II, source, L3 module, No 4 of 6 room temperature measurements using Sr90 Source (multi6) 10x
|
Sr90 Radioactive Source
No cooling
Module position: -5:-30(bottom left) |
Wed May 7 17:33:21 2014, Benedikt Würkner, Belle II, source, L3 module, No 5 of 6 room temperature measurements using Sr90 Source (multi6) 10x
|
Sr90 Radioactive Source
No cooling
Module position: -32:-30(bottom center) |
Wed May 7 18:20:36 2014, Benedikt Würkner, Belle II, source, L3 module, No 6 of 6 room temperature measurements using Sr90 Source (multi6) 10x
|
Sr90 Radioactive Source
No cooling
Module position: -57:-30(bottom right) |
Thu May 8 16:51:03 2014, Benedikt Würkner, Belle II, source, L3 module, No 1 of 6 room temperature measurements using Sr90 Source (single) 10x
|
Sr90 Radioactive Source
No cooling
Module position: 0:0(top left) |
Thu May 8 16:51:57 2014, Benedikt Würkner, Belle II, source, L3 module, No 2 of 6 room temperature measurements using Sr90 Source (single)
|
Failed with Error: "***ERROR*** Init NECO failed, Return code: -32761"
Restarted and it works again
Sr90 Radioactive Source |
Fri May 9 15:12:44 2014, Benedikt Würkner, Belle II, source, L3 module, No 2 of 6 room temperature measurements using Sr90 Source (single) 10x
|
Sr90 Radioactive Source
No cooling
Module position: -27:0(top center) |
Fri May 9 16:44:41 2014, Benedikt Würkner, Belle II, source, L3 module, No 3 of 6 room temperature measurements using Sr90 Source (single) 10x
|
Sr90 Radioactive Source
No cooling
Module position: -54:0(top center) |
Fri May 16 11:37:05 2014, Benedikt Würkner, Belle II, source, L3 module, No 4 of 6 room temperature measurements using Sr90 Source (single) 10x
|
Sr90 Radioactive Source
No cooling
Module position: 0:-10(bottom left) |
Fri May 16 11:38:44 2014, Benedikt Würkner, Belle II, source, L3 module, No 5 of 6 room temperature measurements using Sr90 Source (single) 10x
|
Sr90 Radioactive Source
No cooling
Module position: -27:-10(bottom center) |
Fri May 16 11:40:29 2014, Benedikt Würkner, Belle II, source, L3 module, No 6 of 6 room temperature measurements using Sr90 Source (single) 10x
|
Sr90 Radioactive Source
No cooling
Module position: -54:-10(bottom right) |
Thu Jun 5 10:33:46 2014, Benedikt Würkner, Belle II, source, Silc Module, Silc Angle Measurement 1°
|
Measured the Silc 03/10 Module using the Sr90 Source to have a comparison for the Eta-Distribution at different angles.
Data can be found on heros in: /home/medialib/LAB_Silc_Angle.
Plots made with TuxOA for all different regions can be found in /home/users/bwuerkner/plots/. |
Thu Jun 5 10:34:06 2014, Benedikt Würkner, Belle II, source, Silc Module, Silc Angle Measurement 4°
|
Measured the Silc 03/10 Module using the Sr90 Source to have a comparison for the Eta-Distribution at different angles.
Data can be found on heros in: /home/medialib/LAB_Silc_Angle.
Plots made with TuxOA for all different regions can be found in /home/users/bwuerkner/plots/. |
Thu Jun 5 10:34:29 2014, Benedikt Würkner, Belle II, source, Silc Module, Silc Angle Measurement 7°
|
Measured the Silc 03/10 Module using the Sr90 Source to have a comparison for the Eta-Distribution at different angles.
Data can be found on heros in: /home/medialib/LAB_Silc_Angle.
Plots made with TuxOA for all different regions can be found in /home/users/bwuerkner/plots/. |